Manual de instrucciones de Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300

Manual de instrucciones del aparato Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300

Aparato: Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300
Categoría: Módem
Fabricante: Campbell Manufacturing
Tamaño: 1.19 MB
Fecha de añadido: 8/3/2014
Número de páginas: 40
Imprimir el manual

Descargar

¿Cómo se utiliza?

Nuestro propósito es proporcionarte el acceso más rápido posible a los contenidos incluidos en los manuales de instrucciones del aparato Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300. Utilizando la vista previa online, puedes ver rápidamente el índice de contenidos y pasar a la página donde encontrarás la solución a tu problema con Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300.

Para tu comodidad

Si ver los manuales de instrucción de Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300 directamente en esta página no es cómodo para ti, puedes utilizar dos soluciones posibles:

  • Vista en pantalla completa – Para ver cómodamente los manuales de instrucciones (sin descargarlos en tu ordenador) puedes utilizar el modo de vista en pantalla completa. Para activar la vista del manual Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300 en pantalla completa, utiliza el botón Pantalla completa
  • Descargar al ordenador – también puedes descargar el manual de instrucciones de Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300 a tu ordenador y guardarlo en tu colección. Sin embargo, si no quieres ocupar espacio en tu dispositivo, siempre podrás descargarlo de ManualsBase.
Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300 Manual de instrucciones - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Versión impresa

Muchas personas prefieren no leer el documento en la pantalla, sino en versión impresa. La opción de impresión también está prevista y puedes utilizarla haciendo clic en el enlace más arriba - Imprimir el manual. No tienes que imprimir el manual completo de Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300, solo las páginas que elijas. Ahorra papel.

Resúmenes

A continuación encontrarás resúmenes de los contenidos incluidos en las páginas posteriores del manual de instrucciones para Campbell Manufacturing C A M P B E L L S C I E N T I F I C , I N C COM300. Puedes utilizarlos si quieres ver rápidamente el contenido que se encuentra en la siguientes páginas del manual.

Resúmenes de contenidos
Resumen del contenido incluido en la página 1

INSTRUCTION MANUAL
COM300
Voice Communication Modem
Revision: 10/02
Copyright (c) 1994-2002
Campbell Scientific, Inc.

Resumen del contenido incluido en la página 2

Warranty and Assistance The COM300 VOICE COMMUNICATION MODEM is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinsta

Resumen del contenido incluido en la página 3

COM300 Voice Communication Modem Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Introduction.................................................................1 2. Hardware and Software Requirements .....................1 2.1 COM300 Modem......................................................................................1 2.2 Voice Capable Datalogger ..............

Resumen del contenido incluido en la página 4

COM300 Voice Communication Modem Table of Contents A. CS I/O 9 Pin Serial Port..........................................A-1 A.1 Pin Description.................................................................................... A-1 B. Theory of Operation ...............................................B-1 B.1 Theory of Operation ............................................................................ B-1 C. Changing RAM or PROM Chips in the CR10 ........C-1 C.1 Disassembling the CR10...

Resumen del contenido incluido en la página 5

MADE IN USA 1002 whatever steps are necessary to correct the interference. unacceptable interference to radio and TV reception requiring the operator to take computing device. Operation of this equipment in a residential area may cause This equipment complies with the requirements in Part 15 of FCC Rules for Class A S/N Ringer Equivalence 0.5A.Required Connector USOC RJ11C. Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T CAMPBELL COM300 SCIENTIFIC VOICE SYNTHESIZER

Resumen del contenido incluido en la página 6

COM300 Voice Communication Modem 2.1.1 Specifications • Bell 212A, CCITT V.22, and V.32BIS compatible • Full duplex at 9600 and 1200 baud to datalogger • V.42 LAPM and MNP2-4 error correction • Hayes AT command set • RJ-11C telephone jack • FCC and IC (formally known as DOC) approval • Pulse or tone dialing • Current drain: 100 µ A quiescent, 180 mA active • Direct connection to and powered by CSI dataloggers • Supply requirements: 12 VDC power supply • Internally switches 12 VDC external pow

Resumen del contenido incluido en la página 7

MADE IN USA 1002 whatever steps are necessary to correct the interference. unacceptable interference to radio and TV reception requiring the operator to take computing device. Operation of this equipment in a residential area may cause This equipment complies with the requirements in Part 15 of FCC Rules for Class A S/N Ringer Equivalence 0.5A.Required Connector USOC RJ11C. Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T CAMPBELL COM300 SCIENTIFIC VOICE SYNTHESIZER

Resumen del contenido incluido en la página 8

COM300 Voice Communication Modem G 12V Logan, Utah G 12V SW 12V CTRL CS I/O POWER SE 78 910 11 12 SW 12V IN DIFF 4 5 6 G GH L AG H L AG H L AG E3 AG G G 5V 5V G G CR10X WIRING PANEL MADE IN USA SE 12 34 56 SDM DIFF 1 2 3 G GH L AG H L AG H L AG E1 AG E2 G P1 G P2 G C8 C7 C6 C5 C4 C3 C2 C1 G 12V 12V EARTH GROUND WIRING PANEL NO. CAMPBELL COM300 SCIENTIFIC INC. VOICE SYNTHESIZER Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-75378-MM-T SC12 Cable Ringer Equivalence 0.5A. Required Co

Resumen del contenido incluido en la página 9

MADE IN USA 1002 whatever steps are necessary to correct the interference. unacceptable interference to radio and TV reception requiring the operator to take computing device. Operation of this equipment in a residential area may cause This equipment complies with the requirements in Part 15 of FCC Rules for Class A S/N Ringer Equivalence 0.5A.Required Connector USOC RJ11C. Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T CAMPBELL COM300 SCIENTIFIC VOICE SYNTHESIZER

Resumen del contenido incluido en la página 10

COM300 Voice Communication Modem are listed on its label. Additional technical information from the FCC and IC on the COM300 is available in Appendix D and E, respectively. If any of your telephone equipment is not operating properly, you should remove it immediately from your telephone line, as it may cause harm to the telephone network. If the telephone company notes a problem, they may temporarily discontinue service. When practical, they will notify you in advance of this disconnection.

Resumen del contenido incluido en la página 11

COM300 Voice Communication Modem Appendix F of this manual provides a guide to interpreting the code that is added to the end of the datalogger program file for voice communication. 5. Using the COM300 for Standard Modem Communications in PC208W The COM300 can be used for standard data transmission in PC208W. To establish data communication with the COM300, the dialing string (phone number) must be modified in PC208W to disable voice communication for the duration of that connection (the diali

Resumen del contenido incluido en la página 12

COM300 Voice Communication Modem terms can be renamed to something more descriptive using LoggerTalk. A dialog box to make these changes is invoked by selecting the Menu Strings button from the main LoggerTalk window. Refer to the LoggerTalk on-line help system for more information. 6.4 Using the COM300 to Hear Final Storage Data Output data is normally stored in the datalogger's ring memory (Final Storage). The COM300 can access data in input locations only; it cannot access Final Storage da

Resumen del contenido incluido en la página 13

COM300 Voice Communication Modem 8.2 For Problems Encountered When Making Data Calls 1) Verify you have selected the correct calling modem from PC208W's setup screen. 2) Verify the COM port you are using is activated. As a power saving feature, some notebook computers do not automatically activate the COM ports. 3) Verify nothing else is using the same COM port on the computer. Even if a program is minimized in Windows, it may have a lock on the COM port. 4) PC208W, Campbell Scientific's comm

Resumen del contenido incluido en la página 14

COM300 Voice Communication Modem This is a blank page. 10

Resumen del contenido incluido en la página 15

Appendix A. CS I/O 9 Pin Serial Port The modem’s CS I/O port is not a standard RS232 connection. NOTE A.1 Pin Description The COM300 modem connects to the datalogger using an SC12 cable connected to the devices’ 9-pin subminiature D-type socket connector. This connector is shown in Figure A-1. Table A-1 shows the I/O pin configuration, and gives a brief description of the function of each pin. CS I/O FIGURE A-1. 9 Pin Connector A-1

Resumen del contenido incluido en la página 16

Appendix A. CS I/O 9 Pin Serial Port TABLE A-1. Pin Description ABR = Abbreviation for the function name. PIN = Pin number. O = Signal Out of the datalogger to a peripheral. I = Signal Into the datalogger from a peripheral. PIN ABR I/O Description 1 5V I 5 VDC supply. Not used. 2 SG Signal Ground: Provides a power return for pin 1 (5V), and is used as a reference for voltage levels. 3 RING O Ring: Raised by the modem to put the datalogger in the telecommunications mode. 4 RXD O Receive Data

Resumen del contenido incluido en la página 17

Appendix B. Theory of Operation B.1 Theory of Operation The COM300 modem is used to transmit data over bandwidth-limited channels such as telephone lines by modulating audio tones, using Phase Shift Keying (PSK) at 9600 or 1200 baud and Frequency Shift Keying (FSK) at 300 baud. The telephone company gives a 40 to 150 VRMS, 20 Hz signal on the telephone lines to signify a ring, which is typically on for 2 seconds and off for 4 seconds. The ring detection circuitry is continuously powered but d

Resumen del contenido incluido en la página 18

This is a blank page.

Resumen del contenido incluido en la página 19

Appendix C. Changing RAM or PROM Chips in the CR10 The CR10 has two sockets for Random Access Memory (RAM) and one socket for Programmable Read Only Memory (PROM). The standard CR10 has 64K of RAM, (a 32K RAM chip in each socket). Earlier CR10s had 16K of RAM (an 8K RAM chip in each socket). C.1 Disassembling the CR10 The sockets provided for RAM and PROM are located on the CR10 CPU circuit card inside the CR10 can. To expose the RAM and PROM sockets, remove the two Phillips head screws fro

Resumen del contenido incluido en la página 20

Appendix C. Changing RAM or PROM Chips in the CR10 C.3 Installing New PROM The PROM chip is found at location C8 on the CR10 CPU board, (see Figure C-2). With a small flat screw driver, gently pry out the PROM chip and replace it with the new one. The new chip should be installed so that the notched end is towards the nearest card edge. Before pushing the chip into the socket make certain that all the pins are seating correctly. After installing the chip, check for pins that may be bent or


Manuales de instrucciones similares
# Manual de instrucciones Categoría Descargar
1 Edelbrock 15631 Manual de instrucciones Módem 0
2 3Com 1.024.1644-00 Manual de instrucciones Módem 0
3 3Com OFFICECONNECT 3C886 Manual de instrucciones Módem 5
4 3Com ADSLEthernet Manual de instrucciones Módem 1
5 3Com CableExternal Manual de instrucciones Módem 6
6 Sony GC75 Manual de instrucciones Módem 2
7 Sony SE366 Manual de instrucciones Módem 3
8 Sony MP595 Manual de instrucciones Módem 1
9 Sony TRUINSTALL USB 598 Manual de instrucciones Módem 1
10 Actiontec electronic Actiontec 1520 Manual de instrucciones Módem 2
11 Actiontec electronic 1524 Manual de instrucciones Módem 0
12 Actiontec electronic DataLink 56K Manual de instrucciones Módem 0
13 Actiontec electronic 56K ISA Lite Manual de instrucciones Módem 0
14 Airlink RAVEN-E EV-DO Manual de instrucciones Módem 0
15 Altech Auto Security AL7024S Manual de instrucciones Módem 1