Manual de instrucciones de Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836

Manual de instrucciones del aparato Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836

Aparato: Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836
Categoría: Bomba de agua
Fabricante: Harbor Freight Tools
Tamaño: 0.65 MB
Fecha de añadido: 8/30/2013
Número de páginas: 12
Imprimir el manual

Descargar

¿Cómo se utiliza?

Nuestro propósito es proporcionarte el acceso más rápido posible a los contenidos incluidos en los manuales de instrucciones del aparato Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836. Utilizando la vista previa online, puedes ver rápidamente el índice de contenidos y pasar a la página donde encontrarás la solución a tu problema con Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836.

Para tu comodidad

Si ver los manuales de instrucción de Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836 directamente en esta página no es cómodo para ti, puedes utilizar dos soluciones posibles:

  • Vista en pantalla completa – Para ver cómodamente los manuales de instrucciones (sin descargarlos en tu ordenador) puedes utilizar el modo de vista en pantalla completa. Para activar la vista del manual Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836 en pantalla completa, utiliza el botón Pantalla completa
  • Descargar al ordenador – también puedes descargar el manual de instrucciones de Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836 a tu ordenador y guardarlo en tu colección. Sin embargo, si no quieres ocupar espacio en tu dispositivo, siempre podrás descargarlo de ManualsBase.
Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836 Manual de instrucciones - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Versión impresa

Muchas personas prefieren no leer el documento en la pantalla, sino en versión impresa. La opción de impresión también está prevista y puedes utilizarla haciendo clic en el enlace más arriba - Imprimir el manual. No tienes que imprimir el manual completo de Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836, solo las páginas que elijas. Ahorra papel.

Resúmenes

A continuación encontrarás resúmenes de los contenidos incluidos en las páginas posteriores del manual de instrucciones para Harbor Freight Tools Pacific Hydrostar Portable Utility Pump 65836. Puedes utilizarlos si quieres ver rápidamente el contenido que se encuentra en la siguientes páginas del manual.

Resúmenes de contenidos
Resumen del contenido incluido en la página 1

Portable Utility PUmP
65836
Set UP and oPerating inStrUctionS
®
distributed exclusively by Harbor Freight t ools .
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our website at: http://www.harborfreight.com
read this material before using this product.
Failure to do so can result in serious injury.
SaVe tHiS manUal.
© ®
Copyright 2008 by Harbor Freight Tools . All rights reserved. No portion of this manual or any artwork
contained herein may be reproduced in any shape or form without t

Resumen del contenido incluido en la página 2

notice is used to SaVe tHiS manUal address practices Keep this manual for the safety warn- not related to personal injury. ings and precautions, assembly, operat- caUtion, without ing, inspection, maintenance and cleaning the safety alert procedures. Write the product’s serial symbol, is used to address number in the back of the manual near the practices not related to assembly diagram (or month and year of personal injury. purchase if product has no number). Keep this manual and

Resumen del contenido incluido en la página 3

plugs with grounded power tools. Safety equipment such as dust mask, Unmodified plugs and matching out- non-skid safety shoes, hard hat, or lets will reduce risk of electric shock. hearing protection used for appropri- ate conditions will reduce personal b. avoid body contact with grounded injuries. surfaces such as pipes, radiators, ranges and refrigerators. There is c. Prevent unintentional starting. an increased risk of electric shock if ensure the switch is in the off-po- your body i

Resumen del contenido incluido en la página 4

proved for the specific hazards in the g. Use the power tool, accessories work area. and tool bits etc. in accordance with these instructions, taking into 4. Power tool use and care account the working conditions a. do not force the power tool. Use and the work to be performed. Use the correct power tool for your ap- of the power tool for operations differ- plication. The correct power tool will ent from those intended could result do the job better and safer at the rate in a hazardo

Resumen del contenido incluido en la página 5

• Properly maintain and inspect to groUnding avoid electrical shock. t o PreVent • Any power cord must be properly electric SHocK grounded. Ground Fault Circuit Inter- and deatH From rupter (GFCI) should also be imple- incorrect groUnding mented – it prevents sustained elec- Wire connection: trical shock. Check with a qualified 6. WARNING: Handling the cord on electrician if you are in doubt this product will expose you to lead, as to whether the outlet is a chemical known to the

Resumen del contenido incluido en la página 6

of electric shock. (See 3-Prong Plug 2. Double insulated tools may be used and outlet.) in either of the 120 volt outlets shown in the preceding illustration. (See 2. The grounding prong in the plug is outlets for 2-Prong Plug.) connected through the green wire in- side the cord to the grounding system extension cords in the tool. The green wire in the cord must be the only wire connected to 1. Grounded tools require a three wire the tool’s grounding system and must extension cord.

Resumen del contenido incluido en la página 7

dition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. 8. Protect the extension cords from sharp objects, excessive heat, and damp or wet areas. recommended minimUm Wire gaUge For eXtenSion cordS* (120/240 Volt) eXtenSion cord namePlate lengtH amPereS (at full load) 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 18 14 12 10 - 12.1 – 16.0 14 12 10 - - 16.1 – 20.0 12 10 -

Resumen del contenido incluido en la página 8

note: For additional information regarding SPeciFicationS the parts listed in the following pages, Electrical Requirements 115 V~ / 60 Hz / 8.4 A refer to the Assembly Diagram near the end of this manual. Pumping Capacity 1500 GPH Max. 1” x 11.5 TPI Inlet & Outlet Size (Standard Hose Size) assembly Pump Lift Capacity 120 Feet 1. Inlet and outlet hoses (not included) must be attached to pump prior to use. UnPacKing 2. Attach inlet and outlet hoses to Hose When unpacking, check to make sure

Resumen del contenido incluido en la página 9

5. Never operate this tool in explosive t ool Set Up atmospheres. t o PreVent SerioUS injUry general operating instructions From accidental oPeration: 1. Attach inlet and outlet hoses (not t urn the Power Switch of the included) to pump. Standard garden tool to its “oFF” position and hoses will work. unplug the tool from its 2. Attach accessory Basket Filter to inlet electrical outlet before end of inlet hose. performing any inspection, maintenance, or cleaning 3. Place basket filt

Resumen del contenido incluido en la página 10

a. Remove the brush cap on each side maintenance and of the motor housing. Ser Vicing b. Remove the carbon brushes from Procedures not specifically the housing. Keep track of which explained in this manual orientation the old carbon brush- must be performed only by a es were in to prevent needless qualified technician. wear if they will be reinstalled. c. If either carbon brush is worn down t o PreVent by more than 1/2, replace both car- SerioUS injUry bon brushes. From accidental

Resumen del contenido incluido en la página 11

t roubleshooting Problem Possible causes likely Solutions Tool will not start 1. No power at outlet. 1. Check power at outlet. 2. Cord not connected. 2. Check that cord is plugged in. 3. Worn out or damaged Carbon 3. Replace Carbon Brushes. Brushes. Pump operates 1. Pump is not primed. 1. Prime pump, see instructions page 9. but does not 2. Basket Filter is clogged. 2. Check and clean basket filter. pump water 3. All water has been pumped out. 3. Turn off pump and complete mop up by hand. 4. I

Resumen del contenido incluido en la página 12

aSSembly diagram SKU 65836 For technical questions, please call 1-800-444-3353. Page 12


Manuales de instrucciones similares
# Manual de instrucciones Categoría Descargar
1 Harbor Freight Tools 69297 Manual de instrucciones Bomba de agua 7
2 Harbor Freight Tools 65322 Manual de instrucciones Bomba de agua 0
3 Harbor Freight Tools 93662 Manual de instrucciones Bomba de agua 1
4 Harbor Freight Tools 68328 Manual de instrucciones Bomba de agua 1
5 Harbor Freight Tools 3878 Manual de instrucciones Bomba de agua 0
6 Harbor Freight Tools 45333 Manual de instrucciones Bomba de agua 0
7 Harbor Freight Tools 93819 Manual de instrucciones Bomba de agua 0
8 Harbor Freight Tools 66514 Manual de instrucciones Bomba de agua 0
9 Harbor Freight Tools 68375 Manual de instrucciones Bomba de agua 4
10 Harbor Freight Tools 95591 Manual de instrucciones Bomba de agua 0
11 Harbor Freight Tools 93820 Manual de instrucciones Bomba de agua 1
12 Harbor Freight Tools 69774 Manual de instrucciones Bomba de agua 2
13 Harbor Freight Tools 94639 Manual de instrucciones Bomba de agua 5
14 Harbor Freight Tools 95592 Manual de instrucciones Bomba de agua 0
15 Harbor Freight Tools 9576 Manual de instrucciones Bomba de agua 0
16 Edelbrock 25-4066 Manual de instrucciones Bomba de agua 0
17 A.O. Smith Century Pool & Spa Motor Manual de instrucciones Bomba de agua 156
18 Agilent Technologies Quaternary Pump 1100 Series Manual de instrucciones Bomba de agua 33
19 Aero Mist 50 Series Manual de instrucciones Bomba de agua 0
20 Amtrol GUARDIAN CP DC2 Manual de instrucciones Bomba de agua 3