Resumen del contenido incluido en la página 18
13 57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) EXPORT 13 1 102193 ASSEMBLY, HOT WATER VALVE, 220VAC 220V ONLY EXPORT 13 57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) 220V ONLY 13 57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM) 14 2 83051 WASHER, #8 SCREW SIZE, FLAT 15 7 83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE, 16 17 84002 NUT, HEX, #8-32 MACHINE SCREW 17 1 108002 SWITCHING/CONTROL BOARD, 8 KEYS, D2P (CBS-20
Resumen del contenido incluido en la página 19
EXPORT 57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) 220V ONLY 57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM) 6 83051 WASHER, #8 SCREW SIZE, FLAT 4 84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT 1 57044 VALVE, BYPASS LEFT 120 VAC 57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) EXPORT 1 57077 VALVE, BYPASS LEFT 220 VAC 220V ONLY EXPORT 57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER
Resumen del contenido incluido en la página 20
Figure 4 – CBS-2032e / CBS-2032s Tank Assembly DWG 104027-A 20
Resumen del contenido incluido en la página 1
User’s Guide
www.fetco.com
Models:
CBS-2031e / CBS-2031s
CBS-2032e / CBS-2032s
NOTICE TO INSTALLER: Please leave this book with the machine.
Table of Contents
Contact Information ..................................................2 Operating Instructions ..............................................8
Description & Features .............................................2 Programming ..
Resumen del contenido incluido en la página 2
Contact Information FETCO® Phone: (800) 338-2699 (US & Canada) Food Equipment Technologies Company (847) 719-3000 600 Rose Road Fax: (847) 719-3001 Lake Zurich • IL • 60047-0429 • USA Email: sales@fetco.com techsupport@fetco.com Internet: www.fetco.com Description & Features The CBS-2030e and CBS-2030s series feature patented intermittent spray over technology, which works like this: The following variables are programmed for each batch size: Brew volume Prewe
Resumen del contenido incluido en la página 3
Electrical Configuration and Brewing Efficiency US & Canada CBS-2031e / CBS-2031s 3.0 liters per batch Electrical Heater Voltage Maximum Batches per Hour* (max 11) Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water E31045 1 X 1.5 KW 120 single 2 + ground 1.6 13.0 4.9 11.0 Can be connected 2 X 1.5 KW 120/208 single 3 + ground 2.4 11.3 7.3 11.0 to 120 VAC or 120/220 2.6 12.0 8.2 11.0 120/208-240 VAC 120/240 3.1 13.0 9.7 11.0 E31035 1 X 1.7 KW
Resumen del contenido incluido en la página 4
Dimensions & Utility Connections CBS-2031e / CBS-2031s DWG 201108-000 CBS-2032e / CBS-2032s DWG 201109-000 4
Resumen del contenido incluido en la página 5
Installation (For Qualified Service Technicians Only) Keys To A Successful Installation If not installed correctly by qualified personnel, the brewer will not operate properly and damage may result. Damages resulting from improper installation are not covered by the warranty. Here are the key points to consider before installation: Electrical: All FETCO brewers require NEUTRAL. Ground is not an acceptable substitute. Installation without neutral may cause damage to the electroni
Resumen del contenido incluido en la página 6
Electrical Connection – US & Canada 1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the brewer’s serial number label. Make sure the electrical service includes neutral. 2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters during the installation process. The heaters are disabled by the control board until the tank is full of water. The heating process will start a
Resumen del contenido incluido en la página 7
Final Setup 1. Turn on the incoming water supply line and inspect both inside and outside of the brewer for leaks in all fittings and tubes 2. Turn on the incoming power. 3. Press the brewer’s main power switch, which is hidden behind the front leg of the brewer. The control panel on/off switch will begin flashing. Press this switch. 4. Within 6 seconds, the hot water tank will begin filling until the water is sensed by the probe at the top of the tank. The display will read “FIL”. T
Resumen del contenido incluido en la página 8
Operating Instructions Control Panel Functions Only switches that are active are illuminated. Switches that are inactive or disabled are invisible. Main Power Switch Controls all power to brewer Indicator lamp at top of panel. Control Panel On/Off Switch Affects only control panel. Does not disconnect main power. Flashing = Off Lit = On Invisible = Main Power Off Display ”FILL” = Water tank is filling. ”LO XXX” = Unit is heating, not ready to brew. (XXX = ac
Resumen del contenido incluido en la página 9
Programming Display Batch Settings Turn the brewer off by pressing the main power switch. Press the main power switch again to turn the unit on. 32 The last 2 digits of the model number will display briefly, then S t b. S t b Quickly hold the STOP button for 3 seconds. P r G MAIN POWER The display will show the software version. Example: 0.0 3.2 SWITCH IS BEHIND Press STOP to continue. FRONT LEG. Batches are numbered 1
Resumen del contenido incluido en la página 10
Temperature Settings Parameter Name Range Default Setting Comment 7 Inside tank. Will be slightly lower at Water Temp. ( °F) 180 °F - 208 °F 200 °F spray head. To display in ° Celsius, see # 58 in Advanced Settings. 8 Hot Water Service A (auto) / On / Off A (auto) A= Faucet will dispense only when not brewing. On=Faucet always enabled. Off=Faucet always disabled. 9 Brew at Set 0 - 1 1 0=Will brew at any temperature. Temperature 1=Will brew only at set temperature. Note: Changes
Resumen del contenido incluido en la página 11
Address Description Range Default Comment 60 Left Brew Valve 0.35 – 2.24 1.48 Use this to compensate for minor discrepancies in If #59 is LTR and Flow Rate actual volume versus programmed volume. Set 61 Right Brew Valve lower to increase volume, higher to decrease or Flow Rate volume. The following formula can be used to determine the correct setting: 0.09 – 0.59 0.39 If #59 is GAL ACTUAL VOLUME CURRENT NEW X = PROGRAMMED VOLUME SETTING SETTING 64 Keypad Tes
Resumen del contenido incluido en la página 12
Error Codes How to Clear Error Code Description Possible Cause Corrective Action Codes 001 Internal Error Control board failure. Clear error. Turn main power System had to reload default Re-program the brewer to the switch off and on. settings. desired specifications. If error occurs again, replace control board. 050 Shorted temperature probe. Probe failure. Replace probe. Turn main power switch off and on. 051 Open temperature probe. Bad probe connection, or Check all connections.
Resumen del contenido incluido en la página 13
Parts Figure 1 – CBS-2031e / CBS-2031s Main Assembly DWG 101194-C ITEM # QTY PART # DESCRIPTION 1 1 001051 WELDMENT CBS-2031e 2 1 108001 SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031e ONLY) 2 1 108037 SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031s ONLY) 3 2 29007 NUT, #4-40 KNURLED THUMB 4 4 15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2" 5 1 51042 BOARD, POWER SUPPLY-120VAC EXPORT 5 1 51055 BOARD, POWER SUPPLY-220VAC 220V ONLY 6 4 29019 SPACER, .25" HEX x 1" LG.,
Resumen del contenido incluido en la página 14
14 1 52050 TERMINAL BLOCK 15 1 65002 CONNECTOR, COPPER LUG 16 2 86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA 17 1 102189 ASSEMBLY, POWER BRACKET, CBS-2000e 17 1 52026 CIRCUIT BREAKER, 5A 17 1 58054 SWITCH, PUSH BUTTON 18 7 83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE, 19 13 84002 NUT, HEX, #8-32 MACHINE SCREW 20 1 102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG. 5) EXPORT 20 1 102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG. 5) 220V ONLY 21 1 002065 WELDMENT, HOT WATER
Resumen del contenido incluido en la página 15
Figure 2 – CBS-2031e / CBS-2031s Tank Assembly DWG 104028-A ITEM # QTY PART # DESCRIPTION 1 1 004042 WELDMENT TANK CBS-2031e 2 1 24002 O-RING, TANK COVER 3 1 102013 ASSEMBLY, TANK COVER 4 3 31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD 5 3 83042 WASHER, .875"OD X .562"ID, FLAT 6 1 31081 PLUG, HEX HEAD 1/4" MPT 7 1 25098 FITTING, COMPRESSION MALE CONNECTOR 8 1 31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT 9 2 107025 HEATER ASSY., 1500W/120VAC 9 2 10701
Resumen del contenido incluido en la página 16
16 8 84001 NUT, HEX, #6-32 MACHINE SCREW 17 1 31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD 18 1 83044 WASHER, 1.125"OD X 0.750"ID, FLA 19 1 31071 FITTING, 1/2 HOSE ID X 3/8" MPT 20 3 31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD 21 1 31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT 22 1 13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG 23 2 31128 FITTING, 90 ELBOW, 3/8 HOSE ID X 1/4 MPT 24 1 31027 FITTING, COMPR 90 MALE ELBOW, 3/8 TUBE OD X 1/4 MPT 25 1 13072 OUTLET, INSIDE TAN
Resumen del contenido incluido en la página 17
Figure 3 – CBS-2032e / CBS-2032s Main Assembly DWG 101196-D ITEM # QTY PART # DESCRIPTION 1 1 001050 WELDMENT, CBS-2032e 2 1 104027 ASSEMBLY, TANK CBS-2032e (SEE FIG. 4) 3 1 22041 INSULATION TANK FRONT CBS-2032e 4 1 22042 INSULATION TANK BACK CBS-2032e 5 2 102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG 5) EXPORT 5 2 102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG 5) 220V ONLY 6 1 102189 ASSEMBLY, POWER BRACKET, CBS-2000e 6 1 52026 CIRCUIT BREAKER, 5A 6 1 58054