Résumé du contenu de la page N° 1
Reference Manual
00809-0100-4708, Rev AD
September 2012
Rosemount 708 Wireless Acoustic
Transmitter
www.rosemount.com
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
Reference Manual 00809-0100-4708, Rev AD Rosemount 708 September 2012 Rosemount 708 Wireless Acoustic Transmitter Rosemount 708 Hardware Revision 1 ® HART Device Revision 1 Field Communicator Field Device Revision Dev v1, DD v1 NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure to thoroughly understand the contents before installing, using, or maintaining this product. The United States has two toll-free ass
Résumé du contenu de la page N° 4
Reference Manual 00809-0100-4708, Rev AD Rosemount 708 September 2012 Explosions could result in death or serious injury: Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the Product Certifications section for any restrictions associated with a safe installation. • Before connecting a Field Communicator in an explosive atmosphere, ensure the instruments are
Résumé du contenu de la page N° 5
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Table of Contents SECTION 1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Overview Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 708 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 6
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 APPENDIX A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Functional Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Specifications and Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Reference Data Performance Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 W
Résumé du contenu de la page N° 7
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Section 1 Overview Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1-2 Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1-2 Service Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1-5 Product R
Résumé du contenu de la page N° 8
Reference Manual 00809-0100-4708, Rev AD Rosemount 708 September 2012 OVERVIEW 708 Transmitter Benefits of the Rosemount 708 include: • Improved energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure relief valves • Gain instant visibility to all of your critical steam traps and PRVs ® through a non-intrusive, WirelessHART monitoring system • Know you are backed by Emerson’s proven experience in Smart Wireless field instrumentation and expert techn
Résumé du contenu de la page N° 9
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Wireless Considerations Power Up Sequence The Smart Wireless Gateway (Gateway) should be installed and functioning properly before any wireless devices are powered. Install the power module, SmartPower Solutions, model number 701PGN green power module, into the 708 to power the device. This results in a simpler and faster network installation. Enabling Active Advertising on the Gateway ensures that new devices are able t
Résumé du contenu de la page N° 10
Reference Manual 00809-0100-4708, Rev AD Rosemount 708 September 2012 Field Communicator Connections The Power Module needs to be installed in the device for the Field Communicator to interface with the 708. This transmitter uses the Green Power Module; please order model number 701PGNKF. Field communication with this device requires a HART-based Field Communicator using the correct 708 DD. Field communicator connections are located on the power module. The Power Module is keyed and can onl
Résumé du contenu de la page N° 11
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Heat from the process is transferred to the transmitter housing. If the process temperature is high, the ambient temperature will need to be lower to account for heat transferred to the transmitter housing. See Table 1-1 for process temperature derating. Table 1-1. Temperature Derating Process Temperature (°C) Process Temperature (°F) Max Ambient (°C) Max Ambient (°F) 260 500 41 105.8 240 464 45 113 220 428 49 120.2 200
Résumé du contenu de la page N° 12
Reference Manual 00809-0100-4708, Rev AD Rosemount 708 September 2012 PRODUCT Recycling of equipment and packaging should be taken into consideration. The product and packaging should be disposed of in accordance with local RECYCLING/DISPOSAL and national legislation. 1-6
Résumé du contenu de la page N° 13
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Section 2 Configuration Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Network Configuration . . . . . . . . . . . . . . . . . . . . . page 2-2 Remove Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-3 HART Menu Tree . . . . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 14
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 ® AMS Wireless Configurator AMS Wireless Configurator is capable of connecting to devices directly, using a HART modem, or remotely using the Gateway. To configure the Rosemount 708, double click (or right click and select Configure/Setup) on the device icon that will appear below either the HART modem or Gateway connection tree. DEVICE NETWORK In order to communicate with the Gateway, and ultimately the host system, th
Résumé du contenu de la page N° 15
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Fast Key Sequence Table 2-1 lists the fast key sequence for common transmitter functions. Table 2-1. 708 Fast Key Function Key Sequence Menu Items Sequence Device Information 2, 2, 5 Tag, Long Tag, Descriptor, Message, Date, Country, SI Unit Control Guided Setup 2, 1 Basic Setup, Join Device to Network, Configure Update Rates, Alert Setup Manual Setup 2, 2 Wireless, Sensor, HART, Security, Device Information, Power Wire
Résumé du contenu de la page N° 16
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 HART MENU TREE Figure 2-2. Field Communicator Menu Tree 2-4
Résumé du contenu de la page N° 17
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Section 3 Mounting Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 SAFETY MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated
Résumé du contenu de la page N° 18
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Figure 3-1. Transmitter Alignment Figure 3-2. Transmitter Alignment Top View Figure 3-3. Power Module Installation NOTE: Wireless devices should be powered up in order of proximity from the Gateway, beginning with the closest device to the Gateway. This will result in faster network formation. 3-2
Résumé du contenu de la page N° 19
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Mounting 1. Mounting bands should be inspected periodically and retightened if necessary. Some loosening may occur after initial installation due to Considerations thermal expansion/contraction. 2. The waveguide must be in direct contact with the pipe. 3. Insulate process piping to minimize ambient temperature effects (see Figure 3-4). Insulation thickness over the top of the waveguide foot should not exceed 2.54 cm (1-i
Résumé du contenu de la page N° 20
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 3-4