Résumé du contenu de la page N° 1
�
�
�
�
�
�
�
�
�
INSTALLER/CONSUMER
SAFETY INFORMATION
™
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
Builder Rear Vent
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
Direct Vent
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
Models: 33LDVR, 36LDVR,
SONAL INJURY OR LOSS OF
LIFE.
39LDVR, 43LDVR
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU
Résumé du contenu de la page N° 2
LDVR Series Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Specialty Home Products fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions Important Curing/Burning Instructions ..
Résumé du contenu de la page N° 3
LDVR Series Direct Vent Gas Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified Proposition 65 Warning: Fuels used in gas, wood- installer in accordance with local building codes and with burning or oil fired appliances, and the products of current CSA-B149.1 Installation codes for Gas Burning combustion of such fuels, contain chemicals known to Appliances and Equipment. For USA Installations follow the State of California to cause cancer, bi
Résumé du contenu de la page N° 4
LDVR Series Direct Vent Gas Fireplace Fireplace Dimensions Rough E Opening Depth S R F U V - Rough Opening Width S Rough Centerline of Opening T 7" Collar Height Low � � Voltage Electrical Access Access Q I D B Low C Gas Line Voltage Electrical Access H Access M M J O A N Gas Line K P Access L G Fig. 2 Fireplace specifications and framing dimensions. Ref. 33LDVR 36LDVR 39LDVR 43LDVR A 33” (838 mm) 36” (914 mm) 39” (991 mm) 43” (1092 mm) B 28 ⁷⁄₈” (733 mm) 34¹⁄₄” (870 mm) 34 ¹⁄₄” (870 mm)
Résumé du contenu de la page N° 5
LDVR Series Direct Vent Gas Fireplace Clearance to Combustibles Top of Unit to Ceiling ............................. 36” (914mm) Appliance Top ....................................................... 0” (0 mm) Bottom .................................................. 0” (0 mm) Side ...................................................... 0” (0 mm) Back ..................................................... 0” (0 mm) J I H Venting Black G Surround Concentric sections of DV Vent F Face Mantel T
Résumé du contenu de la page N° 6
LDVR Series Direct Vent Gas Fireplace 33LDVR units: GFRN2I0, GFRL2I0, GFRE2I0 Framing and Finishing 36LDVR units: GFRN2J0, GFRL2J0, GFRE2J0 39LDVR units: GFRN2K0, GFRE2K0 Check fireplace to make sure it is levelled 43LDVR units: GFRN2N0, GFRE2N0 and properly positioned. Gas Specifications To mount the appliance: Max. Min. 1. Choose the location. Input Input Model Fuel Gas Control BTU/h BTU/h 2. This unit comes with four (4) flanges pre-mounted 33LDVRRN Nat Millivolt 16,000 11,200 on bo
Résumé du contenu de la page N° 7
LDVR Series Direct Vent Gas Fireplace Gas Line Installation Remote ON/OFF Switch Installation When purging the gas lines, the front win- dow frame assembly must be removed. 1. Thread the wiring through the holes on the end panels of the fireplace. Take care not to cut the wire or insulation on metal edges. Route the wire to a The gas pipeline can be brought in through the rear conveniently located receptacle box. of the appliance as well as the bottom. Knockouts are 2. Attach the wire to th
Résumé du contenu de la page N° 8
�� ���������� LDVR Series Direct Vent Gas Fireplace INSIDE EB-1 Electrical Box Electrical Box Retaining Screw The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code. OUTSIDE For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70. It is strongly suggested that the wiring of FP580 the EB-1 Electrical Junction Box be
Résumé du contenu de la page N° 9
LDVR Series Direct Vent Gas Fireplace BLACK L1 WHITE L2 POWER CORD GREEN PURPLE PILOT SENSING CLEAR PILOT IGNITER YELLOW M P O O VALVE CIRCUIT BOARD BLUE ORANGE RED ON/OFF SWITCH OR WHITE WALL THERMOSTAT FP1571 Fig. 9 SIT822 Valve with Synetek electronic control wiring diagram. General Venting Your fireplace is approved to be vented either through There must not be any obstruction such as bushes, FP1571 the side wall, or vertically through the roof. garden sheds, fences, decks or utility b
Résumé du contenu de la page N° 10
V V �������� LDVR Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E B C B ����� ����� V L B V ������ ������ V ����� �������� G ������ F V V B M V G B J X B X I V K V A A VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED V CFM145a 1 2 Canadian Installations US Installations CFM145a A = Clearance above grade, veranda, porch, 12” (30cm) 12” (30cm) DV Termin Location deck, or balcony 5/01/01 Rev. 12/
Résumé du contenu de la page N° 11
LDVR Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner D B = C C Combustible A = 6"(152mm) Combustible E A 6"(152mm) Noncombustible V V 2"(50mm) Noncombustible 2"(50mm) V B Balcony - Balcony - with no side wall with perpendicular side wall C = Maximum depth of 48" (1219mm) for recessed H G location. V V D = Minimum width for
Résumé du contenu de la page N° 12
Vertical dimension from the floor of the unit to the center of the horizontal vent pipe LDVR Series Direct Vent Gas Fireplace 30 Twist Lock Pipes 29 When using CFM Corporation twist-lock pipe it is not 28 27 necessary to use sealant on the joints. The only areas 26 of the venting system that need to be sealed with high 25 temperature silicone sealant are the collars on the 24 fireplace and termination, and the sliding joint of any 23 telescopic vent section used in the system. 22 To join the t
Résumé du contenu de la page N° 13
LDVR Series Direct Vent Gas Fireplace Vent Opening for Combustible Wall 9 ³⁄₈” (240mm) 20" Framing (508mm) Detail 10 ³⁄₈” (264mm) Top View Straight Venting Fireplace Hearth DVR584-600 Opening for Noncombustible Wall 20" 20" Rear vent no elbows (508mm) (508mm) Max. Max. 7 ¹⁄₂” 2/99 djt (190mm) VO584-100 Fig. 15 Locate vent opening on wall. 45° 45° Max. Length Adjustable 12” (305mm) Zero Clearance Sleeve #8 Screws (2) VO584-100 Top View REAR VENT-TOP VIEW #8 Screws Vent Opening Rear Vent
Résumé du contenu de la page N° 14
LDVR Series Direct Vent Gas Fireplace Zero Termination Clearance Sleeve Flex Section Appliance Collars Firestop CFM133 Fig. 17 Firestop and zero clearance sleeve in place. CFM133 DVR Series Typical corner install FP1473 2/26/01 sta Finished Wall Fig. 19 Grasp the vent pipe close to the collar and bend to 45° angle. Do not exceed 45°. Vent Termi- nation Rise FP1473 corner flex install 4/04 djt FP1472 Fig. 20 There must be a 1/2” rise per foot length. Vertical Sidewall Applications FP1005
Résumé du contenu de la page N° 15
LDVR Series Direct Vent Gas Fireplace Horizontal plane means no vertical rise exists on this 7 ft. (2134 mm) portion of the vent assembly. • The maximum horizontal vent run is 20 ft. (6.1m) 10 ft. (3048 mm) when the vertical vent rise is 7 ¹⁄₂ ft. (2.3m). (Fig. 21) 90° Elbow = 3 ft. • The maximum number of 90° elbows per side wall installation is three (3). Maximum A + B = 17 ft. (Max.) Vertical Dimension 20 ft. (6.1m) 7 ¹⁄₂ʼ Minimum When 7 ft. 6 in. 48" Horizontal Run is 12" (1.2m) (2
Résumé du contenu de la page N° 16
LDVR Series Direct Vent Gas Fireplace Adjustable Zero Clear- Vertical Sidewall Installation Maximum Length ance Sleeve 12” (305mm) STEP 1 #8 Screws (2) Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole #8 Screws location. Depending on whether the wall is combustible (2) Adjust- or noncombustible, cut opening to size. (Fig. 25) able Zero Clearance For combustible walls first frame in opening. #8 Screws (2) Sleeve Wall Exterior Com
Résumé du contenu de la page N° 17
LDVR Series Direct Vent Gas Fireplace X X X Always install hori- zontal venting on a level plane. CFM138 CFM136 Fig. 28 Measure horizontal length including 2” overlap. Fig. 30 Horizontal length requirement. CFM136 CFM138 X Rear Vent horizontal length Below Grade Installations 4", 7" collar High 2/26/01 sta Temperature Sealant 2/26/01 sta When it is not possible to meet the required vent ter- minal clearances of 12” (305mm) above grade level a snorkel vent kit #7TDVSNORK is required. It
Résumé du contenu de la page N° 18
LDVR Series Direct Vent Gas Fireplace Zero Clearance Vertical Through-the-Roof Applications Sleeve 7TDVSNORK (if required) This Gas Fireplace has been approved for: (Snorkel) Firestop 1. Vertical installations up to 40ʼ (12 m) in height. Up to 4” (102mm) 10ʼ (3 m) horizontal vent run can be installed within 7” Pipe Clearance the vent system using a maximum of three 90° Min. elbows. Window 24" (610mm) Well Minimum* Gravel Maximum 10ʼ Drain (3 m) Minimum 8ʼ (2.4 m) / Foundation Wall Ma
Résumé du contenu de la page N° 19
LDVR Series Direct Vent Gas Fireplace Attic Insulation Shield Max. 8ʼ (2.4m) Joist Typical 45° Ceiling 40ʼ Support (12m) Max. Application 8ʼ (2.4m) 45° Ceiling Instal- 11" lation Upper Floor 11" Joist Typical Roof Support Ap- Firestop Spacer plication Nails (4) Typical Offset Installation FP1021 CFM100 Fig. 34 Typical vertical roof applications. Fig. 35 Place firestop spacer(s) and secure. FP1021 CFM100 Vertical Through-the-Roof Installation If there is room above ceiling level, Typi
Résumé du contenu de la page N° 20
LDVR Series Direct Vent Gas Fireplace Vent Termination Roof Storm Collar Min. 2ʼ Min. 2' (610 mm) Roof Flash- ing Roof Support Attic Insulation 40ʼ Shield (12m) Attic Insulation Joists Joists FP1185 Fig. 38 Minimum termination to roof clearance. FP1022 Fig. 37 Typical straight-up installation. FP1022 Typical Straight Up Installation 1/26/00 djt 20 10007317