Copyright © April 2007 International Thermal Research IN CANADA: IN THE UNITED STATES: th 2431 Simpson Road Suite D3, 4018 NE 112 Ave. Richmond, BC, Canada V6X 2R2 Vancouver, WA, USA 98682 Tel: 1-800-755-1272 or 604-278-1272 Tel: 1-800-993-4402 or 360-993-4877 Fax: 604-278-1274 Fax: 360-993-1105 Email: info@itrheat.com Website: http://www.itrheat.com All rights reserved. No part of this manual may be reproduced or transmitted i
Résumé du contenu de la page N° 3
Table of Contents Section 1, Overview...................................................1-1 1.1 Unpacking the Heating Module ....................... 1-2 1.2 Protect Your Warranty .................................. 1-2 1.3 Oasis™ Heating Module Features.................... 1-3 1.4 Critical Factors.............................................1-5 1.5 Equipment, Tools and Skills ........................... 1-6 1.6 Testing and Inspection.................................. 1-7 Section 2, Mo
Résumé du contenu de la page N° 4
Table of Contents 5.2 Fan System Operation...................................5-2 Features ....................................................... 5-2 Multiple Zone Heating ..................................... 5-3 Accessories and Components Needed................ 5-3 5.3 What NOT to Do ...........................................5-4 5.4 Mounting Locations.......................................5-4 5.5 Procedure....................................................5-5 Section 6, Wiring the
Résumé du contenu de la page N° 5
Table of Contents 8.11 Functions of the Distribution Module (Optional) Zone Control Panel......................................8-10 8.12 Maintenance...............................................8-11 8.13 Protecting the Heating Module and Distribution Module (Optional) ......................8-13 8.14 General Troubleshooting..............................8-13 Section 9, Installing Distribution Module, DM-12 (optional) .................................................................
Résumé du contenu de la page N° 6
Table of Contents List of Figures Figure 1-1 Oasis™ Module ........................................1-1 Figure 1-2 Oasis™ Heating and Distribution Module......1-5 Figure 2-1 Module Dimensions ..................................2-3 Figure 2-2 Module Mounting Brackets.........................2-5 Figure 3-1 Installing the Exhaust System (Bottom Exhaust).....................................3-6 Figure 3-2 The Exhaust Hole Location & Mounting Templ
Résumé du contenu de la page N° 7
Section 1 Overview Thank you for purchasing the Oasis™ Heating Module for recreational vehicles and yachts. The Oasis™ Heating Module is CSA certified only for NOTICE installation into Recreational Vehicles, Manufactured Homes, and Mobile housing. This section covers critical information you need to know before beginning the installation including how to protect your Warranty, and tools and equipment needed. Figure 1-1: Oasis™ Heating Module International Thermal Research
Résumé du contenu de la page N° 8
Section 1, Overview 1.1 Unpacking the Oasis™ Heating Module When you receive the Oasis™ Heating Module: 1 Unpack it carefully. 2 Check each component against the shipping list to ensure that you have everything and that all parts arrived undamaged. 3 If you discover any missing or defective parts call ITR immediately. 4 If you are not installing the Oasis™ Heating Module right away secure all components so none will be misplaced. 5 Before installing the Oasis™ Heating Module read
Résumé du contenu de la page N° 9
Section 1, Overview result in a voided warranty for the entire heating system. Any loss of service or damage as a result of any unapproved modification is the responsibility of the installer. ITR accepts no liability for any damage or loss of service resulting from unapproved modifications. 1.3 Oasis™ Heating Module Features • Efficient • Clean The Oasis™ Heating Module uses a diesel burner (12 VDC) • Quiet controlled by a multi-functional electronic controller as the primary • C
Résumé du contenu de la page N° 10
Section 1, Overview • Fan assisted sealed combustion chamber is designed to use outside combustion air. • Simple, low amperage draw ignition. • Electronically-controlled system with: • automatic Safety Shutdown; • manual-resettable aquastats for safety overheat protection. • LED indicators on the Control Panel for diagnostics. • Patented, proprietary flame sensor. • Heating Module Remote Operating Panel with ON/OFF switch for the diesel burner, AC elements, and engine heat, if inst
Résumé du contenu de la page N° 11
Section 1, Overview Figure 1-2: Oasis™ Heating and Distribution Module 1.4 Critical Factors THE INSTALLATION SHALL BE IN ACCORDANCE WITH THE REGULATIONS OF AUTHORITIES HAVING JURISDICTION The key factors to keep in mind when planning and carrying out the Pay attention to the installation are: notices of “Danger” “Warning” “Caution” • Mounting location restrictions for the Oasis™ Heating Module, and “Notice” in this optional Distribution Module , and exhaust outlet (to reduce ma
Résumé du contenu de la page N° 12
Section 1, Overview • Ability for technician to easily access and service the product, especially fuel, plumbing, and electrical systems. • After installation, ability to purge water and fuel lines and inspect/test entire system using the ITR-supplied Inspection Check Sheet. 1.5 Equipment, Tools and Skills As the user and/or installer, you must be qualified and authorized to do the installation, which requires mechanical aptitude and electrical knowledge. Make sure you comply with ex
Résumé du contenu de la page N° 13
Section 1, Overview screw-down cap, and sturdy enough to mount firmly to a vertical surface. • Up to five (5) thermostats (DC compatible) to allow temperature regulation of the heating zones when connected to the Distribution Module. 1.6 Testing and Inspection After all components have been properly installed according to standard practices, RVIA or ABYC standards, and the recommendations of this Installation and Operating Manual, the Oasis™ Heating Module should be test-operated for
Résumé du contenu de la page N° 14
Section 1, Overview 1-8 The Oasis™ Heating Module
Résumé du contenu de la page N° 15
Section 2 Mounting – Oasis™ Heating Module 2.1 Before You Begin Plan the location of the Oasis™ Heating Module and all its major components in advance to ensure the chosen locations are compatible with installation requirements and within the technical specifications. Consider the following factors to help you decide exactly where best to mount the Oasis™ Heating Module: • Oasis™ Heating Module weight when full (160 lbs). • Ventilation requirements. • Exhaust outlet location and m
Résumé du contenu de la page N° 16
Section 2, Mounting the Oasis™ Heating Module Make sure you are familiar with Section 1 – Overview of this ! WARNING Manual. If the system is not installed according to specifications and with the correct equipment, your Oasis™ Heating Module may not operate properly, safety may be compromised, and your Warranty may be voided. 2.2 Identifying Your Oasis™ Heating Module Model As the owner, you must be fully aware of the controls and operating features particular to your model of t
Résumé du contenu de la page N° 17
Section 2, Mounting the Oasis™ Heating Module • Combustion air must be drawn from an outside source and cannot contain any combustible gases. • Oasis™ Heating Module must be mounted in an area that provides unrestricted access to the front panel. Allow space for connection to the fuel and coolant lines, as well as the power and exhaust connections. (Minimum of 10” top clearance - top exhaust version; minimum of 6” top clearance - bottom exhaust version; 0” clearance to all other Oasis™
Résumé du contenu de la page N° 18
Section 2, Mounting the Oasis™ Heating Module parts that may cause injury through accidental contact should be protected. Isolate the unit in a closed compartment so that no air from the ! DANGER heater will infiltrate the living areas. • It is recommended that a catchpan be placed under the Oasis™ Heating Module for containing any unexpected leakage. • Choose a sturdy surface in a location that won’t be unduly affected by vibration and the jarring of rough roads or rough seas. •
Résumé du contenu de la page N° 19
Section 2, Mounting the Oasis™ Heating Module Figure 2-2: Module Mounting Brackets International Thermal Research 2-5
Résumé du contenu de la page N° 20
Section 2, Mounting the Oasis™ Heating Module 2-6 The Oasis™ Heating Module