ページ1に含まれる内容の要旨
FV95A Series All-Position Gas Furnace
FV95A Series
All-Position Gas Furnace
95% AFUE – Two-Stage, Variable Speed
STANDARD FEATURES:
Designed for all-position installation: upflow, downflow and horizontal
40" high, for ease of installation
AL 29 - 4C stainless steel secondary heat exchanger
Industry-proven, integrated hot surface ignition control with igniter
and flame sensor positioned in coolest part of flame for ultimate
performance and longevity
Aluminized-steel multi-port in-shot burners pr
ページ2に含まれる内容の要旨
Product Specifications 95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE Model Number FV95A0543A FV95A0723A FV95A0905A FV95A1085A Position All-Position All-Position All-Position All-Position Electrical Characteristics Volts 120 120 120 120 Hertz 60 60 60 60 Phase 1 1 1 1 Operating Voltage Range (Min-Max) 102 - 132 102 - 132 102 - 132 102 - 132 Max Fuse or CKT Breakers (Amps) 15 15 15 15 Minimum Wire Size 14 14 14 14 Performance Data - Input BTUH Low 35,100 46,800 58,500 70,200 High 5
ページ3に含まれる内容の要旨
Product Specifications 95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE Model Number FV95A0543A FV95A0723A FV95A0905A FV95A1085A Gas Controls Minimum Inlet Pressure (in. wc) 5 5 5 5 Maximum Inlet Pressure (in. wc) 13.6 13.6 13.6 13.6 Gas Inlet (Inches) 1/2 1/2 1/2 1/2 LP Convertible Yes Yes Yes Yes Low Nox Capability Standard Standard Standard Standard Ignition Device Type Hot Surface Hot Surface Hot Surface Hot Surface General Component Limit Control SPST SPST SPST SPST Transformer
ページ4に含まれる内容の要旨
Product Specifications 95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE - ACCESSORIES Unit Size - FT95A Series Part Number 0543A 0723A 0905A 1085A Concentric Termination Kit - 2 Inch KGAS101CTKA-2 X X X C X X oncentric Termination Kit - 3 Inch KGAS101CTKA-3 X X X X Condensate Freeze Protection Kit KGAS101CPKA X X X X Natural to Propane Gas Conversion Kit KGAS101ANPA Propane to Natural Gas Conversion Kit KGAS101APNA X X X X EC motor Simulator KGAS101EMSA X X X X Door Gasket Kit KGAS1
ページ5に含まれる内容の要旨
Product Specifications NOMENCLATURE: F V 95 A 054 3 A *A Brand F = Fedders Revision Letter Description V = Two Stage, Variable Speed Product Generation AFUE A = 1st Generation 95 = 95% AFUE Air Flow Direction A = All-position Maximum CFM @ 0.5" ESP 3 = 1200 Heating Capacity (BTUH) 4 = 1600 054 = 70,000 5 = 2000 072 = 85,000 090 = 90,000 108 = 108,000 Fedders Corporation All product specifications reflect available information at the printing of this specification sheet. 505 Martinsville Rd. Fe