ページ1に含まれる内容の要旨
MPD 32072
TM
hydro flame
7900-II / 8000-II
9
Series Furnace
Technical Installation Manual
ENGLISH, FRANCAIS (et Canada) •Installation
Effective 1/08
THIS INSTRUCTION MANUAL IS FOR USE BY AN AUTHORIZED SERVICE
INDEX
TM
TECHNICIAN TO INSTALL AN ATWOOD - hydro flame FURNACE.
FURNACE SPECIFICATIONS ..............................................................1
DIMENSIONS ..................................................................1
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
WEIGHT .....
ページ2に含まれる内容の要旨
Spacing of 1/4˝ to ducting within 3 feet of furnace must be provided Return air is supplied through openings in furnace grille. The return air passage unless UL listed wire bound vinyl ducts are used. All ducting material must be kept clear for furnace to function properly. Refer to MINIMUM CLEARANCE should be rated for continuous use of 200˚F. TO FLOORBOARDS, WALLS & SIMILAR COMBUSTIBLE BUILDING MATERIAL. NOTE: If zero clearance is maintained from furnace to cabinet structure, a STANDARD FURNA
ページ3に含まれる内容の要旨
be in front of door to furnace. Provide an access opening for service ELECTRICAL CONNECTION and/or removal of furnace. The furnace must be side ducted (NO front discharge). Secure furnace to floor with one screw FIG 4-J. WARNING 5. Remove cover plate from furnace FIG 4-D. To install duct adapters for INJURY OR PROPERTY DAMAGE side discharge models, insert back flange over casing and insert tab • Label all wires before disconnecting for service. Wiring errors can cause improper, into square not
ページ4に含まれる内容の要旨
A B D C NOTE: The ON/OFF switch, GROUND located in line with the gas valve, is not used when a MOTOR 8 Black combination circuit breaker Red Black ELECTRODE and ON/OFF switch is used. White CIRCUIT BREAKER IMPORTANT Wiring must On/Off Switch Red LIMIT be replaced with wire rated Red +12V DC VALVE 105˚C or higher. Black NEG White SAIL SWITCH Pwr Blw DSI 5179 Yellow CONTROL Red White Red THERMOSTAT Black Blue High Tension VENT CABINET DEPTH VENT KIT NO. EXTENSIONS VENTING CHART V DIM.F DIM.M D
ページ5に含まれる内容の要旨
TM hydro flame 7900-II / 8000-II Series Furnace 29 Appareil de chauffage à air chaud 28 30 Série 7900-II / 8000-II 8 11 6 12 24 23 5 13 4 27 3 7 2 1 16 26 17 14 18 10 15 30 25 31 21 20 9 19 22 Item # Description of Parts Item # Description of Parts Élément n˚ Description des pièces 1 Front Door 24 Motor Spacer 12 Moteur (80-II) 2 Electronic Ignition Board 25 Small Burner Air Baffle - SPECIFY RATE 13 Ventilateur d'air de combustion 3 Valve 25 Large Burner Air Baffle - SPECIFY RATE 14 Adaptateur