Siemens Hicom cordless EM Convenience mobile unit 2000C pocket user manual

User manual for the device Siemens Hicom cordless EM Convenience mobile unit 2000C pocket

Device: Siemens Hicom cordless EM Convenience mobile unit 2000C pocket
Category: Cordless Telephone
Manufacturer: Siemens
Size: 0.92 MB
Added : 9/23/2013
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens Hicom cordless EM Convenience mobile unit 2000C pocket. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens Hicom cordless EM Convenience mobile unit 2000C pocket.

For your convenience

If looking through the Siemens Hicom cordless EM Convenience mobile unit 2000C pocket user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens Hicom cordless EM Convenience mobile unit 2000C pocket on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens Hicom cordless EM Convenience mobile unit 2000C pocket to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens Hicom cordless EM Convenience mobile unit 2000C pocket User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens Hicom cordless EM Convenience mobile unit 2000C pocket but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens Hicom cordless EM Convenience mobile unit 2000C pocket. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

General Features Features of the DECT* mobile unit ● Illuminated graphical display with battery charge display ● Status-dependent function menus ● Number redial for the last five numbers dialled ● Telephone directory in the mobile unit for approx. 100 entries ● Enhanced user guidance with displays in German, English, French, Spanish, Italian, Portuguese or Dutch ● Language setting, see page 54 ● En-bloc dialling with correction option ● Automatic talk feature** on removal of handset from cha

Summary of the content on the page No. 3

General General Telephone directory . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Contents Entering letters/characters and digits . . . . . . . . . . . . . . . 31 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview – directory submenu . . . . . . . . . . . . . . . . . . . . 33 Controls, unit parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Storing numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Dialli

Summary of the content on the page No. 4

General General General ● Local functions can also be performed in the charging Hicom cordless EM Leaving the radio network shell. ® The Hicom cordless EM DECT telephone system com- ● Before saving, local functions can be cancelled with the ● Integrated power saving function: If you leave the base menu key or the on-hook key . station radio range when the mobile unit is switched on, prises the interval between synchronisation attempts gradually ● the radio exchange for the Hicom 150 E sy

Summary of the content on the page No. 5

Summary of the content on the page No. 6

Summary of the content on the page No. 7

Putting the mobile unit into service Putting the mobile unit into service Putting the mobile unit into service e.g. . Enter the mobile unit system code Logging mobile units onto a telephone system Activating/deactivating mobile units ... (eight-digit) and confirm the entry with >>>>>>>> For information on setting the language, see page 54. the display key – ✱ symbols are dis- ● Off status: display clear – calls are not received! played instead of digits. Your system administrator suppli

Summary of the content on the page No. 8

Telephone functions Telephone functions Telephone functions This display when the mobile is External dialling En-bloc dialling for internal/external dialling on is a prerequisite and initial status for all telephone functions (see also En-bloc dialling means that you enter the number first (up to Press the talk key - the user’s own "Radio range" on page 8). , 32 digits), if necessary correct it and then press the talk key mobile unit number a

Summary of the content on the page No. 9

Telephone functions Telephone functions Switching functions . Prerequisite: The required function is set up. Editing a number Number redial – last five numbers Press the display key. You have dialled a number, but the other party is busy or Automatic callback Scroll to the desired number. does not answer: press the on-hook key. The last five If a dialled internal user is busy or if your call is not numbers dialled (up to 32 digits) are always stored auto- answered, you can program an aut

Summary of the content on the page No. 10

Summary of the content on the page No. 11

Switching functions Switching functions Switching functions System- System- System- Standard Standard Standard 1 1 1 Functions ) specific Functions ) specific Functions ) specific code code code 2 2 2 code ) code ) code ) Associated dialling ✱67+ DTMF dialling (tone dialling)(Short cut) ✱53 Switch actuation, on ✱90 Set up connections for other partner+ Transmit DTMF signals. off #90 telephones. ph. no. To switch on/off certain devices (e.g. Night service on ✱44+✱ relay). Ov

Summary of the content on the page No. 12

Telephone directory Telephone directory Telephone directory Your mobile unit has a telephone directory for storing up to Overview – key layout Overview – directory submenu 100 numbers, see also Note on page 41. The stored numbers can be simply dialled, modified or Submenu Explanation/note deleted at any time. Access to the telephone directory is Dial Number see page 35 locked if the mobile unit is locked. New Entry see page 33 –Save Entry see page 36 äö ü ß 1 , – Insert Function see page

Summary of the content on the page No. 13

Telephone directory Telephone directory Telephone directory Inserting a function: Dialling a number from the telephone directory Editing/deleting/displaying an entry You can enter a pause, e.g. following an international prefix, Prerequisite: Number is stored and mobile unit is "on" – The stored entries – numbers and/or names – can be edited, when you are entering the telephone numbers. * no connection is set up (idle) deleted or displayed. Press the display key. M i + Press the display key –

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Main menu – functions Main menu – functions Main menu – functions S Switch to entering the short cut Short cuts Selecting the base contents. ? Short cuts make it easier to perform "longer" operating If your mobile unit is logged onto more than one base Press the recall key. @BADC sequences, e.g. automatic callback or other code functions. (DECT systems*), you can set it to a particular base or Enter the code "✱58". "best base" (automatic base changeover). Store a function (operating sequence)

Summary of the content on the page No. 16

Main menu – functions Settings Settings Prerequisite: Overview – settings Settings – handset, ringer, etc. You have selected a specific base as described above and ’ have called up the submenu . The display shows: Press the menu key. Setting Explanation/notes Level Default 6 Scroll to (!)!*!*+ ,-!. 7899: ;<= Handset Call volume; and confirm. !! " >? Volume Level 1 is not shown in the 31 #!##!##!###!##!##!#!##!# display!

Summary of the content on the page No. 17

Settings Settings Settings ISDN configuration Base settings Overview – handset settings Not relevant for cordless EM. You can rename the preset base names "Base 1" through Setting Explanation/notes Level Default "Base 6". Within a company, for example, base 1 could be De-registering a base changed to "Plant 1" and base 2 changed to "Plant 2". Beeps see page 49 – – The mobile unit should not be de-registered! Auto The backlight is switched on On/Off On Backlight when the first key is Changing

Summary of the content on the page No. 18

Settings Settings Settings Overview – beeps Beeps – keys, battery, range... Select services The stored default select services (operating sequences Press the menu key. Beep type Explanation, note Default for Telecom services) cannot be used with cordless EM. Scroll to ! Key Beeps Audible each time a key is On and confirm. pressed. "# o,po Saving functions under Batt. Low Beep Audible approx. 5 minutes before On the battery runs out. Scroll to

Summary of the content on the page No. 19

Settings Settings Settings PIN Enter the mobile unit PIN and Changing the mobile unit PIN Setting the language confirm. Prerequisite: The mobile unit is on (German default !"$# You can use this function to change your personal mobile %! &’ (") unit PIN. The default PIN is "0000". state*!) *"+, The mobile unit PIN is required for the following functions: Press the menu key. Press the display key – = – changing the mobile unit PIN is

Summary of the content on the page No. 20

Settings Settings Appendix Settings after the mobile unit has been reset: Resetting the mobile unit to the default state Troubleshooting Telephone directory: Retained You can use this function to reset your mobile unit to the Before contacting the Service department, you should Short cuts: Retained defined default state, e.g. if you are handing over your attempt to correct any errors yourself: Redial: Deleted mobile unit to another user. Mobile unit PIN: As per last save Error Possible cause R


Alternative user manuals
# User manual Category Download
1 Siemens Gigaset 2400 User manual Cordless Telephone 76
2 Siemens 2011 User manual Cordless Telephone 43
3 Siemens Gigaset 2410 User manual Cordless Telephone 19
4 Siemens 2015 User manual Cordless Telephone 200
5 Siemens Gigaset 2010 User manual Cordless Telephone 218
6 Siemens 3000 V3.0 User manual Cordless Telephone 4
7 Siemens Gigaset 242 User manual Cordless Telephone 37
8 Siemens GIGASET 4010 HWCD8518(3)P/TSDL User manual Cordless Telephone 140
9 Siemens C2 User manual Cordless Telephone 92
10 Siemens 2060isdn User manual Cordless Telephone 67
11 Siemens A110 User manual Cordless Telephone 103
12 Siemens Gigaset 4015 User manual Cordless Telephone 235
13 Siemens Gigaset 4000 User manual Cordless Telephone 109
14 Siemens Gigaset 3000 User manual Cordless Telephone 227
15 Siemens Gigaset 4200 User manual Cordless Telephone 73
16 Sony SPP-111 User manual Cordless Telephone 34
17 Sony SPP-A2470 User manual Cordless Telephone 4
18 Sony PP-A2780 User manual Cordless Telephone 5
19 Sony SPP-933 User manual Cordless Telephone 21
20 Sony SPP-934 User manual Cordless Telephone 7