Lifebreath 850FD/DD user manual

User manual for the device Lifebreath 850FD/DD

Device: Lifebreath 850FD/DD
Category: Air Cleaner
Manufacturer: Lifebreath
Size: 1.02 MB
Added : 7/17/2013
Number of pages: 31
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lifebreath 850FD/DD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lifebreath 850FD/DD.

For your convenience

If looking through the Lifebreath 850FD/DD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lifebreath 850FD/DD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lifebreath 850FD/DD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lifebreath 850FD/DD User manual - Online PDF
Advertisement
« Page 1 of 31 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lifebreath 850FD/DD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lifebreath 850FD/DD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
CLEAN • FRESH • AIR
OPERATION AND
INSTALLATION MANUAL
NOTE: ALTHOUGH SOME MODELS
For Models:
DIFFER IN OPERATION, THE BASIC
500DCS ControlAir 15
STEPS ARE SIMILAR.
850FD/DD Analog Controls CAUTION
Before installation, careful consideration must be given to
how the system will operate if connected to any other piece
700FD/DD Analog Controls
of mechanical equipment, i.e. a forced air furnace or air
handler, operating at a higher static. After installation, the
compatibility of the two pieces o

Summary of the content on the page No. 2

Table of Contents INTRODUCTION HRV - Aluminum Core Introduction .................................................................... 2 ERV Questions and Answers ......................................... 3 A Heat Recovery Ventilator (HRV) is designed to Select Correct HRV/ERV to Match Climate.....................4 provide fresh air into a building while exhausting Select the Correct Size HRV/ERV ................................ 5 an equal amount of stale air. During the winter months, the incomi

Summary of the content on the page No. 3

ERV Questions & Answers What is the difference between an HRV and damp situation. In fact, about 2/3 of the energy and an ERV? used by the air conditioner system is to remove The core in an HRV (Heat Recovery Ventilator) moisture. Therefore, when ventilating in the summer, transfers heat from one air stream to the other. This is less moisture brought into the home means less work called sensible heat. The term ERV (Energy Recovery for the air conditioner, and energy savings for you. Ventilator)

Summary of the content on the page No. 4

4

Summary of the content on the page No. 5

Selecting the Correct Size HRV/ERV Commercial and Institutional Requirements For outdoor air requirements, ASHRAE has produced the Ventilation Standard 62-1989 that is used to determine acceptable ventilation rates. This standard is referenced directly or used as “Good Engineering Practice” in most Code documents or design criteria. Small restaurants, Donut Shops and Fast food stores Bank Seats 40 Customers 25 Employees 5 Staff 9 Total 45 Total 34 ASHRAE requirement 20 cfm (10L/s) per person AS

Summary of the content on the page No. 6

Model 500DCS SPECIFICATIONS PERFORMANCE CORES AIRFLOWS (Each Air Stream) Modular (4 section) patented aluminum heat recovery cores arranged for high efficiency crossflow ventilation. 282 (600) MOTORS 235 (500) 6.3 HIGH SPEED Two PSC, 5 speed double shafted, 120 VAC, 3.15 Amps each (6.3 total 5 3.8 MED 190 (400) on high speed). HP - 1/10, 1625 RPM. Watts - total on High Speed - 610. 4 3.1 LOW 3 143 (300) FILTERS 2 1 94 (200) Washable air filters in exhaust and supply air streams. BLOWERS

Summary of the content on the page No. 7

HIGH SPEED MED SPEED LOW SPEED Model 850FD/DD SPECIFICATIONS PERFORMANCE CORES Modular (6 section) patented aluminum heat recovery cores arranged for high AIRFLOWS (Each Air Stream) efficiency crossflow ventilation. 475 (1000) MOTORS 425 (900) Two PSC, 3 speed double shafted, 120 VAC, 3.95 Amps each (7.9 total on 378 (800) 7.9 HIGH high speed). HP - 1/4, 1625 RPM. Watts - total on High Speed - 848. 329 (700) 7.0 MED FILTERS 282 (600) Washable air filters in exhaust and supply air s

Summary of the content on the page No. 8

Model 700FD/DD SPECIFICATIONS MODEL 700FD, 700DD PERFORMANCE CORES Modular (2 section) patented aluminum heat recovery cores AIRFLOWS (Each Air Stream) arranged for efficient cross-flow ventilation. MOTORS 423 (900) Two PSC, 3 speed single shafted, 120 VAC, 2.75 Amps each (5.5 378 (800) total on high speed). HP - 1/10, 1625 RPM. Watts - total on high 329 (700) 5.5 HIGH HIGH SPEED speed - 648. 282 (600) 5.0 MED MED SPEED FILTERS 235 (500) 4.7 LOW LOW SPEED Washable air filters in exhaust and s

Summary of the content on the page No. 9

Model 1200FD/DD PERFORMANCE SPECIFICATIONS CORES AIRFLOWS (Each Air Stream) Modular (3 section) patented aluminum heat recovery cores arranged 613 (1300) for efficient cross-flow ventilation. 566 (1200) 8.1 HIGH MOTORS 518 (1100) Two PSC, 3 speed double shafted, 120 VAC, 4 Amps each (8.1 total on 7.8 MED HIGH SPEED 472 (1000) high speed). HP - 1/4, 1625 RPM. Watts - total on high speed - 972. 423 (900) FILTERS 7.1 LOW MED SPEED 378 (800) Washable air filters in exhaust and supply air stream

Summary of the content on the page No. 10

® Model 500ERV CLEAN • FRESH • AIR PERFORMANCE SPECIFICATIONS AIRFLOWS (Each Air Stream) LATENT RECOVERY (MOISTURE) TRANSFER CORES Modular (4 section) 2- Enthalpic, 2 Aluminum arranged for high 282 (600) efficiency crossflow ventilation. 235 (500) 6.3 HIGH SPEED MOTORS - Two PSC, 5 speed double shafted, 120 VAC, 3.15 Amps 5 3.8 MED 190 (400) 4 each (6.3 total on high speed). HP - 1/10, 1625 RPM. Watts - total on 3.1 LOW 3 143 (300) 2 High Speed - 610. 1 94 (200) FILTERS - Washable air filter

Summary of the content on the page No. 11

® Model 700ERV CLEAN • FRESH • AIR SPECIFICATIONS PERFORMANCE AIRFLOWS (Each Air Stream) LATENT RECOVERY (MOISTURE) TRANSFER CORES 423 (900) Modular (2 section) enthalpic (moisture) transfer cores arranged for efficient cross-flow ventilation. 378 (800) 329 (700) 5.5 HIGH MOTORS HIGH SPEED 282 (600) 5.0 MED Two PSC, 3 speed single shafted, 120 VAC, 2.75 Amps each MED SPEED 235 (500) 4.7 LOW (5.5 total on high speed). HP - 1/10, 1625 RPM. Watts - total LOW SPEED 190 (400) on high speed - 648.

Summary of the content on the page No. 12

® Model 1200ERV CLEAN • FRESH • AIR SPECIFICATIONS PERFORMANCE LATENT RECOVERY (MOISTURE) TRANSFER CORES AIRFLOWS (Each Air Stream) Modular (3 section) latent recovery (moisture) transfer cores arranged for efficient cross-flow ventilation. 613 (1300) 566 (1200) MOTORS 8.1 HIGH 518 (1100) Two PSC, 3 speed double shafted, 120 VAC, 4 Amps each 7.8 MED HIGH SPEED 472 (1000) (8.1 total on high speed). HP - 1/4, 1625 RPM. Watts - total 423 (900) on high speed - 972. 7.1 LOW MED SPEED 378 (800)

Summary of the content on the page No. 13

Location for Mounting The Ductwork System The HRV/ERV must be located in a conditioned A properly designed ducting system will allow the space where the surrounding air temperature HRV/ERV to operate at its maximum efficiency. does not fall below 60˚F (16˚C). The unit must be (Air flow will be restricted by undersized ducting, mounted level (horizontal). The warranty will be use of too many elbows, tees, bends, etc.). void if these conditions are not met. Always try to keep duct runs as short an

Summary of the content on the page No. 14

Outside Weatherhoods The weatherhoods must have built-in “bird” screen with All duct joints must be fastened with screws, rivets or 1/4 in (63.5 mm) minimum mesh to prevent birds and duct sealant and wrapped with a quality duct tape to rodents from entering into the ductwork. Do not use prevent leakage. We recommend aluminum foil tape. smaller mesh as it will be very susceptible to plugging up. Gravity dampers at the vents must not be used as Stale Air Return System they will restrict air flow

Summary of the content on the page No. 15

Fresh Air Supply System The Integrated HVAC System Figure A and B The fresh air supply ductwork from the HRV/ERV may be directly connected to the return air duct of the The HRV/ERV has become an integral component of forced air system. Check the air flow balance of the the HVAC system. Figure A shows an HRV/ERV unit HRV/ERV with the air handler blower both “ON” and providing fresh air directly to the return air plenum of a “OFF” to determine that it does not imbalance the rooftop heat/cool unit.

Summary of the content on the page No. 16

The Integrated HVAC System ECONOMIZER ROOFTOP UNIT SUPPLY DUCT RETURN AIR DUCT or BREATHER T FRESH AIR B.D. HRV/ERV UNIT SUPPLY B.D. STALE AIR HRV/ERV FRESH EXHAUST AIR SUPPLY STALE AIR EXHAUST TO HRV/ERV Figure A Example only - Duct connections not typical ECONOMIZER ROOFTOP UNIT ROOF DECK 12" BREATHER CEILING RETURN AIR PLENUM SUPPLY DUCTWORK SPACE FRESH AIR B.D. HRV/ERV UNIT SUPPLY B.D. STALE AIR HRV/ERV FRESH STALE AIR EXHAUST EXHAUST AIR SUPPLY Example only - Duct connections not typic

Summary of the content on the page No. 17

Various Installation Types NOTE: When installing your HRV/ERV Figure 7A flexible duct connectors should Saddle Installation be installed between the HRV/ERV and the galvanized duct work. Vibration Isolators (Supplied by others) Threaded rod and U channel (Supplied by others) Hang unit with suspended rods Figure 7B and "U" channel members. Curb Mounted Curb is wood or metal May be anchored to (Supplied by others) floor,leaving space for drain connections Mount unit on wooden or

Summary of the content on the page No. 18

Electrical Connections accumulation. After the defrost period, the fresh air It is recommended that a licensed electrician make all supply fan automatically returns to the normal speed electrical connections. It is very important that the and fresh outside air continues to be drawn into the unit be properly grounded. It is recommended that a building. Water from the melted frost collects in the separate 15 amp/120 volt circuit be used. bottom drip pans and drains out through the bottom dra

Summary of the content on the page No. 19

Speed Selection and Controls Model 700, 850 and 1200 HRV/ERV only These models are equipped with a 3 speed remote location as well as from high to low from control, low medium and high, as well as a a remote location. To wire the unit in this lighted on/off switch and a 4 screw terminal strip. configuration you would need two electrical on/off The terminal strip can be used to connect any switches to be installed at the remote location low voltage device which will then jump the unit into a dou

Summary of the content on the page No. 20

ControlAir 15 OPTIONAL REMOTE CONTROLS Model 500 Only PROGRAMMABLE VENTILATION CONTROLLER (PVC) NEW! AIR SENTRY™ AIR QUALITY SENSOR LOCATION: Hallway, kitchen, office LOCATION: Kitchen, basement, & work place (connect 1/unit only) work place (connect 1/unit only). • Advanced digital remote. • Digital Air Quality Monitor. • Digital dehumidistat. • Status light indicates fan speed. • Full fan speed control. • Increases ventilation to remove • AIR SENTRY™ Air Quality Sensor built-in. odours


Alternative user manuals
# User manual Category Download
1 Lifebreath 1000RHCAC User manual Air Cleaner 2
2 Lifebreath 1200FD/DD User manual Air Cleaner 0
3 Lifebreath 155MAX RX User manual Air Cleaner 5
4 Lifebreath 155ECM User manual Air Cleaner 2
5 Lifebreath 200ERV User manual Air Cleaner 1
6 Lifebreath 195ECM User manual Air Cleaner 0
7 Lifebreath 1200ERV User manual Air Cleaner 0
8 Lifebreath 500DCS User manual Air Cleaner 0
9 Lifebreath 195DCS User manual Air Cleaner 3
10 Lifebreath 1200DDPOOL User manual Air Cleaner 0
11 Lifebreath 500ERV User manual Air Cleaner 1
12 Lifebreath 200MAX RX User manual Air Cleaner 1
13 Lifebreath 300DCS User manual Air Cleaner 0
14 Lifebreath 200ERVD User manual Air Cleaner 0
15 Lifebreath CONTROLAIR 15 95MAX User manual Air Cleaner 3
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9