TOA Electronics ALARM INPUT UNIT C-AL80(L) user manual

User manual for the device TOA Electronics ALARM INPUT UNIT C-AL80(L)

Device: TOA Electronics ALARM INPUT UNIT C-AL80(L)
Category: Home Security System
Manufacturer: TOA Electronics
Size: 0.22 MB
Added : 4/9/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for TOA Electronics ALARM INPUT UNIT C-AL80(L). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with TOA Electronics ALARM INPUT UNIT C-AL80(L).

For your convenience

If looking through the TOA Electronics ALARM INPUT UNIT C-AL80(L) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual TOA Electronics ALARM INPUT UNIT C-AL80(L) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual TOA Electronics ALARM INPUT UNIT C-AL80(L) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
TOA Electronics ALARM INPUT UNIT C-AL80(L) User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual TOA Electronics ALARM INPUT UNIT C-AL80(L) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to TOA Electronics ALARM INPUT UNIT C-AL80(L). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
ALARM INPUT UNIT C-AL80(L)
C-AL80(H)
POWER
ON
OFF
Note
The C-AL80 Alarm Input Unit is designed to be used in conjunction with TOA's C-RM500 Remote
Controller to enable their alarm operations or remote control. Thus, the C-AL80 Alarm Input Unit can
only be used while connected to a C-RM500 Remote Controller.
Thank you for purchasing TOA's Alarm Input Unit. Please carefully follow the instructions in this manual
in order to ensure long, trouble-free use of your Alarm Input Unit.

Summary of the content on the page No. 2

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ................................................................................ 3 2. GENERAL DESCRIPTION ............................................................................. 4 3. HANDLING PRECAUTIONS .......................................................................... 4 4. NOMENCLATURE AND FUNCTIONS Front Panel ............................................................................................................... 5 Rear Panel .....

Summary of the content on the page No. 3

1. SAFETY PRECAUTIONS • Before installation or use, be sure to carefully read all the instructions in this section in order to ensure long, trouble-free operation. • Be sure to follow all the precautionary instructions in this section, which contain important warnings regarding safety. • After reading, keep this manual handy for future reference. Safety Symbol and Message Conventions Safety symbols and messages are used in this manual to prevent bodily injury and property damage which could resu

Summary of the content on the page No. 4

Indicates a potentially hazardous situation which could result in moderate or minor personal injury, and/or property damage if ignored CAUTION or mishandled. When Installing the Alarm Input Unit • Never insert nor remove the power supply plug with wet hands, as an electric shock may result. • When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. The power supply cord may be damaged, possibly causing a fire or electric shock. • Do not block

Summary of the content on the page No. 5

4. NOMENCLATURE AND FUNCTIONS [Front Panel] 1 2 POWER ON OFF Cover LEVEL REMOTE OFF The inside of ABBREVIATION No.9001 ON REMOTE the cover ALARM 12 3 4 12 3 4 OFF ABBREVIATION No.1 REMOTE ON UNIT No. EDGE 3 4 (4) Mode Selection Switch [Alarm/Remote, (1) Power Switch [ON/OFF ] Abbreviation No. 1–/Abbreviation No. 9001–, Remote ON/Remote OFF, Edge/Level] Used to turn power on and off. (From left to right) (2) Power Indicator 1) Switches the rear panel-mounted terminal block input between "Al

Summary of the content on the page No. 6

[Rear Panel] 11 7 ALARM/ / REMOTE IN MASTER / SLAVE OFF ON TERMINATION RS-232C CAMERA SELECT OUT ALARM / REMOTE OUT 10 5 6 8 9 (5) Power Inlet (8) Camera Selection Output Terminal [Camera Selection Output] Connects to the supplied power supply cord. It cannot be used. (6) Alarm/Remote Input Terminal [Alarm/Remote Input] (9) Alarm/Remote Output Terminal [Alarm/Remote Output] Use the Mode Selection switch (4) to perform input function settings. When set to "Alarm" input, an It cannot be

Summary of the content on the page No. 7

5. MODE SELECTION SWITCH SETTINGS Perform settings of Alarm/Remote input, and alarm intervals here. LEVEL REMOTE OFF Note ABBREVIATION No.9001 Make sure that the Power switch is set to OFF when REMOTE setting each Mode Selection switch. The Mode switch is not correctly set if the Power switch is set to ON. ALARM 12 3 4 ABBREVIATION No.1 REMOTE ON EDGE 5.1. Alarm/Remote Input Settings Using Mode Selection switch 1, select either "Alarm" or "Remote" for Alarm/Remote input. Set the switch to the l

Summary of the content on the page No. 8

5.3. Alarm/Remote Output Settings It cannot be used. Please fix to the "Remote OFF" (Factory-preset position: "Remote OFF") REMOTE OFF 3 REMOTE ON 5.4. Alarm Interval Settings Set the alarm time interval to "Edge" or "Level" with Model Selection LEVEL switch 4. Selecting "Edge" causes the system to operate on alarm for a specified period of time (Alarm Interval set by the Remote 4 Controller) when an alarm signal is received. If "Level" is selected, the system continues to operate on alarm as lo

Summary of the content on the page No. 9

6. USING THE ALARM/REMOTE FUNCTION 6.1. Alarm/Remote Input The Alarm/Remote input terminals on the rear panel are designed to be used for both alarm and remote inputs. Select either input with the Mode Selection switch. (Refer to p. 7.) Alarm input: Enables spot alarm operations using such external equipment as sensors. Remote input: Selects the channel and position of the camera corresponding to the abbreviation number when shorted to GND. (Only the channel is selected for other cameras than

Summary of the content on the page No. 10

7. CONNECTION EXAMPLE 7.1. Connection to the C-RM500 Remote Controller RS-232C reverse cable D-sub 9 pins/female to D-sub 9 pins/female C-RM500 Camera control Switcher control terminal Alarm input terminal terminal GND GND RS-232C Fixed cameras Twisted pair shielded cable Multi-Switcher C-MS161D Video input Input Input + GND – + GND – Alarm input/output Video input/output Input Output Dedicated remote control terminal Monitor output Remote control termination: OFF A 1 1 B 2 Camera con

Summary of the content on the page No. 11

7.2. Master/Slave Connection Example For details about unit number settings, etc., refer to p. 19; Master/Slave Connections. RS-485 Termination switch (11) Unit Number Setting switch (3) C-AL80 Alarm Input Unit OFF ON Master Unit Termination ON OFF 12 3 4 Unit No. RS-485 Termination switch (11) Unit Number Setting switch (3) ON OFF Slave Unit 1 Termination ON OFF 12 3 4 Unit No. RS-485 Termination switch (11) Unit Number Setting switch (3) OFF ON Slave Unit 2 Termination ON OFF 12 3 4

Summary of the content on the page No. 12

8. MASTER/SLAVE CONNECTIONS An entire system can have up to 256 Alarm/Remote inputs through master/slave connections (cascade connections) of up to 8 C-AL80 Units. 8.1 Unit Number Settings Be sure to set the unit number when making master/slave connections. Because each component is factory-preset to the unit number for individual use (same setting as the master unit), change the number when making a master/slave connection. Note ON Make sure that the Power switch is set to OFF when changing ea

Summary of the content on the page No. 13

• Master/Slave Terminal Cable Type Use the supplied DIN plug and the twisted pair cable with plug for connection between the Master/Slave terminals. Refer to the figure shown below and note the correct polarity when making the connection. Pin No. 1 – Pin No. 1 Control signal (positive) Pin No. 3 – Pin No. 3 Control signal (negative) Do not connect pins Nos. 2, 4, and 5. 3 1 5 4 2 Master/Slave terminal Master/Slave terminal 3 3 1 1 5 5 4 4 2 2 Note Incorrect wiring may result in the unit's fail

Summary of the content on the page No. 14

ARARM UNIT C-AL80 9. RACK MOUNTING When mounting the C-AL80 Unit in an equipment rack, remove 4 plastic feet on the bottom plate and attach an optional MB-23B mounting bracket. C-AL80 M4x12 binding head screw (supplied with MB-23B) 5x12 S-tight screw (supplied with MB-23B) supplied with MB-23B Fiber washer (supplied with MB-23B) Note • Use the Alarm Input Unit in locations with ambient temperature of between +0°C and +40°C. • Be sure to mount the Alarm Input Unit below the heat gener

Summary of the content on the page No. 15

10. IF A FAILURE IS DETECTED... (TROUBLESHOOTING) Symptom Cause Cannot switch power on. • The supplied AC cord is not connected to the C-AL80 Unit's Power inlet and AC outlet. Cannot activate an alarm. • The C-AL80 Unit is not correctly connected to the Remote Controller. • The C-AL80 Unit's Mode Selection switch is not set to "Alarm." • [Sensor Alarm] is not set to "ON" on the Remote Controller menu. • Abbreviation number corresponding to the Remote Controller is not registered. • If a master/

Summary of the content on the page No. 16

11. SPECIFICATIONS [C-AL80(L), C-AL80(H)] Power Source (L) : AC110 – 120 V, 50/60 Hz (H) : AC220 – 240 V, 50/60 Hz Power Consumption 3 W(60 mA) 6 W(60 mA) Alarm/ Remote Input 32 channels, no-voltage make contact input, open voltage : 5V DC, short-circuit current : max. 5 mA, M3 screw terminal, distance between barriers : 7.62 mm Control Input/ Output 1 channel, RS-232C, D-sub connector (9P, male) (only valid for master unit), fixse to 38,400 bps Master/ sub Connection Terminal 2 channels, RS-48


Alternative user manuals
# User manual Category Download
1 TOA Electronics ALARM INPUT UNIT C-AL80(H) User manual Home Security System 0
2 TOA Electronics N-VR2010 User manual Home Security System 1
3 3Com 1000BASE-T-GBIC User manual Home Security System 0
4 Sony BRCSDP12 User manual Home Security System 3
5 3Com TECHD-0000000122 User manual Home Security System 1
6 Sony SSC-M354 User manual Home Security System 3
7 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
8 Sony SNC-RX SNC-CS50 User manual Home Security System 4
9 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
10 Sony CD-7226 User manual Home Security System 1
11 Sony Ssc-M383 User manual Home Security System 6
12 Sony Snc Df50n User manual Home Security System 1
13 Sony SNC-RX SNC-RZ50 User manual Home Security System 20
14 Sony BLUETOOTH MEX-BT2500 User manual Home Security System 10
15 4XEM IPCAMW40 User manual Home Security System 1