APC NetShelter NS1435A user manual

User manual for the device APC NetShelter NS1435A

Device: APC NetShelter NS1435A
Category: Indoor Furnishings
Manufacturer: APC
Size: 1.18 MB
Added : 7/16/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC NetShelter NS1435A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC NetShelter NS1435A.

For your convenience

If looking through the APC NetShelter NS1435A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC NetShelter NS1435A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC NetShelter NS1435A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC NetShelter NS1435A User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC NetShelter NS1435A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC NetShelter NS1435A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation and
Customization
NetShelter CX
Enclosures
ns1435a

Summary of the content on the page No. 2

This manual is available in English on the APC Web site (www.apc.com). Dieses Handbuch ist in Deutsch auf der APC Webseite (www.apc.com) verfügbar. Este manual está disponible en español en la página web de APC (www.apc.com). Ce manuel est disponible en français sur le site internet d’APC (www.apc.com). Questo manuale è disponibile in italiano sul sito web di APC (www.apc.com). 本マニュアル<各国の言語に対応する>は APC ウェブサイト (www.apc.com) からダウ ンロードできます 。 Instrukcja obs³ugi w jêzyku polskim jest dostêpna na stron

Summary of the content on the page No. 3

Contents General Information........................................................ 1 Important Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Related Documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 User Comments

Summary of the content on the page No. 4

Removing and Installing Fan Modules . . . . . . . . . . . . . . . . . . . . . . . . 9 Unlock the fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Lock the fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Removing the fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installing the fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Rack PDU. . . . . . . . . .

Summary of the content on the page No. 5

General Information Important Safety Information Read the instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exi

Summary of the content on the page No. 6

Disclaimer The information presented in this manual is not warranted by Schneider Electric to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational and site specific development plan. Therefore, Schneider Electric assumes no liability for damages, violations of codes, improper installation, or any other problems that could arise based on the use of this publication. The information contained in this publication is provided as is

Summary of the content on the page No. 7

Product Overview Description NetShelter CX enclosures are specialized enclosures with integrated cooling, noise dampening, and power distribution for server and network applications in office environments. The enclosures provide storage for industry-standard (EIA-310), 19-inch rack-mount hardware, which includes servers, voice, data, networking, internetworking, and APC power protection equipment. NetShelter CX Enclosures Rack Mounting Rack Mounting External Model Availability Height Width

Summary of the content on the page No. 8

Product Inventory Enclosure components † Top cable access port Leveling foot 1 8 Fan module Vertical mounting flange 2 9 Side panel Front vertical OU accessory channel 3 : † Key Front door 4 ; † Bottom trim Airflow opening 5 < Rear cable access port Fan module power supply 6 = Caster Basic Rack PDU 7 > † The bottom trim, leveling feet, door keys, and rack PDU power cord (not shown) are not installed and can be found inside the enclosure. 4 NetShelter CX Enclosure: Installation and Customizatio

Summary of the content on the page No. 9

Important Information Tools Other tools required (not provided) Phillips screwdriver Utility knife Level Cage nut tool Safety Important Safety Instructions Save These Instructions This manual contains important instructions that must be followed during installation, operation, and maintenance of the equipment. Use caution when moving an empty enclosure on its casters; the enclosure may be unstable when pushed or pulled from the side. Push the enclosure from the front or back when moving it o

Summary of the content on the page No. 10

Configuration Before installing the enclosure, plan the location and space needed to install equipment, and plan the ergonomics of keyboards and video monitors. Improper airflow could damage installed components. Blanking panels Use blanking panels to close up large open spaces in the CX but not to completely seal the rack. The NetShelter CX works best when air can travel not just through the equipment vents, but also above and below any equipment that generates thermal energy. APC offer

Summary of the content on the page No. 11

Three hinges are attached to their mountings in the enclosure to complete door installation. 38 and 24U racks have three hinges per door. The 18U racks have two hinges per door. Removal. 1 Press on the hidden latch under the side arm. 2 Lift the hinge arm off the mounting plate 3 Slide the latch and door away from the mounting plate. When all hinges are detached from their mountings, the door can be removed. NetShelter CX Enclosure: Installation and Customization 7 ns1968a ns1533b ns1532b

Summary of the content on the page No. 12

Installation Installation and Setup If equipment mounting rails are adjusted from their standard factory installed positions to a deeper position, such as in a networking application, the levelling feet must be used. Note: The bottom trim and leveling feet are packaged separately and placed in the enclosure. Leveling the enclosure and installing bottom trim Level the enclosure before installing equipment. The leveling feet at the corners provide a stable base if the floor is uneven, but they ca

Summary of the content on the page No. 13

Removing and Installing Fan Modules Unlock the fan module Open the right hand side panel. Unscrew the thumbscrew on the right side of the fan module to unlock the fan module so it can be opened. Lock the fan module Open the right hand side panel. Install the thumbscrew on the right side of the fan module to lock the fan module in place. Removing the fan module Start at the top when removing the fan modules. 1. Detach the clip. 2. Swing the fan module out on its hinges. 3. Disconnect the fan

Summary of the content on the page No. 14

Rack PDU The NetShelter CX Enclosure is provided with one Basic Rack PDU. The Rack PDU distributes power to devices in the enclosure. AP9567 - North American Outlets. The Rack PDU has fourteen (14) NEMA 5015R outlets. Power cord. The 12-foot (3.66-meter) power cord terminates with a NEMA 5-15P plug. AP9568 - International Outlets. The Rack PDU has fifteen (15) IEC-320-C13 outlets. Power cord. The 6.5-foot (1.98-meter) power cord terminates with a IEC-320-C14 plug. Specifications Electrical AP95

Summary of the content on the page No. 15

Vertical Mounting Flanges Vertical mounting flanges come factory-installed on the enclosure in the proper position for use with rack-mountable equipment having a depth of 800 mm (31.5 in). The front mounting flanges are adjustable towards the rear of the enclosure to accommodate different rails or equipment with other depths.The rear mounting flanges are adjustable towards the front. The flanges can be adjusted to be as close as 120 mm (4.7 in) or as far as 880 mm (34.6 in) apart in 40 mm

Summary of the content on the page No. 16

Installing Equipment This section provides information on how to install rack-mount equipment in the enclosure. The instructions provided with the equipment provide more detailed information. Identifying one U-space on the vertical mounting flange When installing equipment, locate the top and bottom of a U-space on the mounting flanges. Every third hole on the mounting flanges of a NetShelter enclosure is numbered to indicate the middle of a U-space. A U-space consists of one of these numbere

Summary of the content on the page No. 17

Equipment Planning Guidelines Please note the following guidelines for proper installation and operation of hardware in a NetShelter CX Enclosure. Avoid clustering hot-running equipment such as servers, dense redundant arrays of independent disks (RAID), and large voice-over-internet-protocol (VOIP) switches in one part of the enclosure. Distribute the thermal load evenly up and down the enclosure such that each fan module supports an equal amount of the thermal load. Each fan module

Summary of the content on the page No. 18

Dimensions Enclosure dimensions internal Reduction in internal cabinet depth in some rack units due to triangular protrusion of fan modules. Dimension key. • a. 775 mm (30.5 in) • b. 800 mm (31.5 in) • c. 860 mm (33.5 in) • d. 1010 mm (39.5 in) • e. Indicates soundproofed cable entry/exit pathway. Enclosure dimensions. AR4018A AR4024A AR4038A AR4018IA AR4024IA AR4038IA Rear Front rack rack posts posts Rear Front rack rack posts posts Rear Front rack rack posts posts 14 NetShelter CX Enc

Summary of the content on the page No. 19

Cable Management The NetShelter CX enclosure has a cable access opening (cable port) at the rear of the enclosure. The 38U enclosure has an additional cable port at the top for cabling from above. Four vertical 0U accessory channels are factory installed in the enclosures. A variety of other cable management accessories are available. Visit the website at www.apc.com and go to the NetShelter CX product page for a full list of compatible cable management accessories. Rear cable access port The

Summary of the content on the page No. 20

Cable management options for 600-mm and 750-mm enclosures Product SKU Description Figure 19-inch AR8602 (1 U) Route patch cables horizontal horizontally at the cable AR8600 (2 U) front or rear of a organizers 19-inch EIA AR8601 enclosure. (2 U double sided) AR8603A (2 U high density) AR8113A Cable Fastens cables to management posts, mounting rings rails, or braces. 19-inch AR8425A Routes cables horizontal (1U) horizontally on the cable front or back of the organizer AR8426A 19-inch EI


Alternative user manuals
# User manual Category Download
1 APC Netshelter Sx Ar3814 Enclosure Rack Cabinet AR3814 User manual Indoor Furnishings 1
2 APC NetShelter AR4038A User manual Indoor Furnishings 1
3 APC Netshelter Sv 42u Wide 600x1060mm Sides AR2400 User manual Indoor Furnishings 5
4 APC Rack Systems User manual Indoor Furnishings 0
5 Sony User manual Indoor Furnishings 1
6 Sony XL-2000K User manual Indoor Furnishings 1
7 Sony SU-32FS2 User manual Indoor Furnishings 3
8 Sony PSS-610 User manual Indoor Furnishings 10
9 Sony HVL-LBP User manual Indoor Furnishings 8
10 Sony SU-GW1 User manual Indoor Furnishings 2
11 Sony SU-27FS2 User manual Indoor Furnishings 0
12 Sony SU-36FS2 User manual Indoor Furnishings 0
13 Sony 210 User manual Indoor Furnishings 0
14 Sony SU-27HX1 User manual Indoor Furnishings 0
15 Sony SU-36XBR8 User manual Indoor Furnishings 1