Verilux ClearWave CWST2RB user manual

User manual for the device Verilux ClearWave CWST2RB

Device: Verilux ClearWave CWST2RB
Category: Indoor Furnishings
Manufacturer: Verilux
Size: 0.8 MB
Added : 4/10/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Verilux ClearWave CWST2RB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Verilux ClearWave CWST2RB.

For your convenience

If looking through the Verilux ClearWave CWST2RB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Verilux ClearWave CWST2RB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Verilux ClearWave CWST2RB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Verilux ClearWave CWST2RB User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Verilux ClearWave CWST2RB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Verilux ClearWave CWST2RB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CWST2RB
Soothing Skin System

Summary of the content on the page No. 2

Please read the entire instruction manual before operating the ® ClearWave Soothing Skin System. Table Of Contents ® The Science of ClearWave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Is this Product Right for You? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

® The Science of ClearWave Scientifi c studies have confi rmed the effectiveness of 415-430 nanometer (nm) blue light, and 630-660nm red light in eliminating acne forming bacteria, promoting healing, and the production of collagen in the dermal layer of the skin. A study published in the Journal of Cosmetic Dermatology in 2006 outlined red light LED’s ability to energize the cells, producing increased levels of collagen and elastin. This increased cellular activity provides for fi rmer, smoo

Summary of the content on the page No. 4

Is This Product Right For You? ® ® The ClearWave Soothing Skin System provides Natural Spectrum light for a daily skin care regimen. The System includes two interchangeable heads that provide 600 cycles of use in each. The Blemishes Head uses LEDs to emit blue light at 420 nanometer (nm) to help eliminate bacteria, reduce the appearance of pimples and facial blemishes, and prevent future blemishes from forming. The Fine Lines and Wrinkles Head uses LEDs to emit red light at 660nm to help so

Summary of the content on the page No. 5

Warnings ® Always use eye protection while operating the ClearWave Soothing Skin System to avoid potential eye damage. ® Do not use the ClearWave Soothing Skin System if you are taking photosensitizing medications or using photosensitizing topical creams. These may cause an adverse reaction. If you experience prolonged redness or sensitivity of the area you are caring for, discontinue use and consult your healthcare professional as soon as possible. ® Do not use the ClearWave Soothing Skin

Summary of the content on the page No. 6

Product Overview ® The ClearWave Soothing Skin System is an over-the-counter device designed to naturally reduce the appearance of fi ne lines, wrinkles, and blemishes. Contents Include: a. Device Body ® b. Two Replaceable Natural Spectrum Interchangeable Heads c. Charging Stand d. Power Supply e. Rechargeable battery (factory installed) f. Protective Eyewear (goggles) g. Instructions for Use a. Fine Lines Blemishes & Wrinkles b. c. e. f. d. Accessories • Charging Stand • Goggles • Power Su

Summary of the content on the page No. 7

Controls and Status Information Indicators Controls b. a. Power Button b. Head Latch Buttons a. Status Indicators c. Information Display c. d. Battery Life Indicator Lights d. e. Interchangeable Head Life Indicator Lights e. Information Display Indicators Display Mode Explanation Reference Number Operating Time remaining on current care cycle Page 10 Number Idle Number of care cycles remaining on head Page 13 0 Idle Interchangeable Head is exhausted Page 15 – – – Interchangeable Head is not co

Summary of the content on the page No. 8

Getting Started ® Before you use the ClearWave Soothing Skin System, you will need to fully charge the device. It takes approximately 12 hours to fully charge the battery for the fi rst time. Step 1: Connect the power adapter to the Charging Stand and the plug into a 110V grounded electrical outlet. Step 1 ® Step 2: Place the ClearWave Soothing Skin System on the Charging Stand, as shown. Step 2 Step 3: The Battery Life Indicator Lights will provide information to you on the status w

Summary of the content on the page No. 9

Operating Instructions Proper Use Operations Note:  For best results, remove all make-up and wash your face with a neutral pH cleanser.  During use, hold the device in a single location until Step 1 the cycle is complete. Step 1: To ACTIVATE, push the Power Button until the device beeps once, indicating that the care cycle is ready to begin. Step 2: Apply protective eyewear (goggles). Step 2 Step 3: T o START, place the device against the desired area of your skin to receive care. Th

Summary of the content on the page No. 10

Care Cycle Interruption If the device is removed from the skin during a cycle: • The Interchangeable Head will turn off. • The Information Display will show the remaining time in the cycle. • The Interchangeable Head Life Indicator and Battery Life Indicator Lights will display the current status level. • The system will beep continuously for 30 seconds as a reminder that the care cycle has been interrupted. To resume, return the device to the same area of your skin and complete the cyc

Summary of the content on the page No. 11

Charging Mode Note:  To receive the optimal dosage during a care cycle, fully charge the ® ClearWave Soothing Skin System before use. A fully discharged device can require up to 12 hours of charging.  When the bottom Battery Life Indicator Light is fl ashing and the Information Display is displaying “LO”, the battery is low.  Device can be used in charging mode if connected directly to the power adapter. To Charge Using Charging Stand: Step 1: Connect the power adapter to the Charging

Summary of the content on the page No. 12

Heat Protection Mode Note: Consecutive uses and high ambient temperatures can cause the Interchangeable Head surface to become hot. The device monitors the Head surface temperature during each care cycle to ensure that the Head maintains an optimum temperature. Once the device has reached the optimum temperature limit, it will enter Heat Protection Mode and the device will limit operation until suffi cient surface cooling has been achieved. When the Information Display is displaying “HP”, th

Summary of the content on the page No. 13

Replacing the Interchangeable Heads Blemish Head • 420 nanometer of blue light soothes infl amed pores to help restore your skin to a healthy glow. Fine Lines and Wrinkles Head • 660 nm of red light helps to eliminate pimples and blemishes and fi ne lines and wrinkles deep in the skin. To Remove the Interchangeable Head: Step 1: Press and hold both Head Latch Buttons shown on each side of the Head. Step 2: Separate the Interchangeable Head from the Device Body. To Install an Interchange

Summary of the content on the page No. 14

How to Replace the Battery Step 1: With the charger unplugged, loosen the screw to the battery compartment using a Philips head screwdriver. Step 2: Unplug the battery cable attached to the battery. Step 3: Remove the battery and dispose in accordance with local environmental regulations. Step 4: Insert new battery and plug in cable. Step 5: Replace the compartment cover and tighten the screw. ® The ClearWave Soothing Skin System battery is made specifi cally for the ® ® ClearWave by

Summary of the content on the page No. 15

Troubleshooting If problems occur with the device, which are not outlined in this Instruction ® Manual, contact Verilux Customer Service at 1-888-544-4865. Any damage ® caused by an attempt to disassemble the ClearWave Soothing Skin System will void the warranty. The Issue The Problem The Solution The audio signals: 5 fast beeps Properly and fully The Information Display signals: Interchangeable Head is attach Head. not attached See page 13 for instructions. The audio signals: 3 beeps Interch

Summary of the content on the page No. 16

One-Year Limited Warranty ATTENTION! ONCE OPENED, PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE WHERE IT WAS PURCHASED FOR REPAIR OR REPLACEMENT! Many questions may be answered by visiting www.Verilux.com, or you may call our customer service department at 1-888-544-4865. This limited warranty is provided by: Verilux, Inc., 340 Mad River Park, Waitsfi eld, VT 05673 ® Verilux warrants this product to be free from defects in material and workmanship for a period of one year from the date of the


Alternative user manuals
# User manual Category Download
1 Verilux DESK AND TABLE LAMP VD05 User manual Indoor Furnishings 0
2 Verilux HAPPYLIGHT VTCP01 User manual Indoor Furnishings 10
3 Verilux Floor Lamp User manual Indoor Furnishings 0
4 Verilux DELUXE NATURAL SPECTRUM VF08 User manual Indoor Furnishings 0
5 Verilux NATURAL SPECTRUM VF02 User manual Indoor Furnishings 0
6 Verilux Pagelight VB04 User manual Indoor Furnishings 0
7 Verilux Mood Enhancement System VT01 User manual Indoor Furnishings 0
8 Verilux LEGACY DELUXE NATURAL SPECTRUM VF04 User manual Indoor Furnishings 0
9 Verilux PLANETLIGHT PL05 User manual Indoor Furnishings 0
10 Verilux PLANETLIGHT PL03 User manual Indoor Furnishings 0
11 Verilux Sanitizing Light Wand VH11 User manual Indoor Furnishings 0
12 Verilux PL01PLANETLIGHT User manual Indoor Furnishings 0
13 Verilux PLANETLIGHT PL04 User manual Indoor Furnishings 0
14 Verilux VD03 User manual Indoor Furnishings 1
15 Verilux VD04 User manual Indoor Furnishings 1
16 Sony User manual Indoor Furnishings 1
17 Sony XL-2000K User manual Indoor Furnishings 1
18 Sony SU-32FS2 User manual Indoor Furnishings 3
19 Sony PSS-610 User manual Indoor Furnishings 10
20 Sony HVL-LBP User manual Indoor Furnishings 8