Curtis Computer 833 user manual

User manual for the device Curtis Computer 833

Device: Curtis Computer 833
Category: Marine Instruments
Manufacturer: Curtis Computer
Size: 0.09 MB
Added : 3/28/2014
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Curtis Computer 833. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Curtis Computer 833.

For your convenience

If looking through the Curtis Computer 833 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Curtis Computer 833 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Curtis Computer 833 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Curtis Computer 833 User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Curtis Computer 833 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Curtis Computer 833. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL 833
“FUEL” GAGE/HOUR METER
W/“PUSH-
®
Read Instructions Carefully !
!

Summary of the content on the page No. 2

Safety Instructions ! This instrument was manufactured and tested according to the applicable technical standards. It complies with all the safety regulations as shipped from the factory. Installation and startup must be performed by skilled personnel. Failure to install and operate the unit in accordance with these instructions may result in damage or injury. If safe operation of the instrument can no longer be ensured, stop and secure it against accidental operation. If instrument failure or m

Summary of the content on the page No. 3

TABLE OF CONTENTS Page 1. Model Encodement 2 2. Technical Specifications 2.1 Electrical 4 2.2 Mechanical 5 2.3 Environmental 6 3. Installation 7 4. Operation 14 5. Troubleshooting 16 6. Maintenance 17 !

Summary of the content on the page No. 4

1. MODEL ENCODEMENT 833RB vvvv w Voltage Reset level B = 2.09 VPC 0024 2

Summary of the content on the page No. 5

xy zzzz Discharge profile Output 316O C = Adjustable J = N.C. holding relay O = Curtis (See Table 3.) Contact rating = logo 3 Amps when continuously closed, 1 Amp when opening ! 3

Summary of the content on the page No. 6

2. TECHNICAL SPECIFICATIONS ! 2.1 Electrical Operating Range ± 25% of nominal voltage Operating Current Voltage (volts) Nominal Current (mA) Maximum Current (mA) 24 18 28 Relay Contact Ratings Voltage: 200 VDC (max) Current: 1 ADC (max) (3 ADC max when continuously closed) Power: 50 W (max) 4

Summary of the content on the page No. 7

2.2 Mechanical Display ! Battery state-of-charge: 10-bar, tri-color LED Hour Meter: 6-digit LCD, 5mm high Resolution Hour Meter 99,999.9 Hours Hardware Kit Mounting bracket, thumbnuts or M4 Hex nuts (2), lock washers (2), mating connector Molex No. 39-01-2085, w/pins No. 39-00-0039, no connectors in bulk shipments. Panel Cutout 1 52mm, 2 / ” diameter 16 5

Summary of the content on the page No. 8

2.3 Environmental ! Temperature Operating: -40°C to +65°C (Standard Mode) -10° C to +65° C (Push-to-read Mode) Storage: -50°C to +90°C Humidity 95% RH (Non Condensing) at 38°C Shock & Vibration 2.2 G, 20-200 Hz; 20 minute period; X,Y,Z, 13 cycles each Enclosure IP65 (face) 6

Summary of the content on the page No. 9

3. INSTALLATION The Model 833 Installation Kit includes a ! pre-assembled mating connector with 5” terminated wires. Ask for Curtis Part Number 15369002. The Model 833 fits into a dash-panel cutout measuring 1 2 / ” (52 mm). 16 Terminal Assignment (see diagram on page 13) Pin 8 = Battery + Pin 8 to battery + 7

Summary of the content on the page No. 10

Pin 5 = Battery – Connect to battery ground as close to battery ! as possible. Pin 2 = Keyswitch The keyswitch turns on and off the LED display of the battery discharge indicator. Monitoring of the battery continues when Pin 2 is turned off and the display is not lit. The hour meter display is unaffected by Pin 2, although it cannot accumulate more time as long as the keyswitch pin is not energized. The control input HRM (+) is enabled by the keyswitch. Pin 2 is connected to the vehicle’

Summary of the content on the page No. 11

Pin 3 = Relay (+) Pin 3 connects in series with the lift coil circuit (or the circuit to be switched at empty). For holding relay (J), Pin 3 must be electrically closer to battery + than Pin 4 Pin 4 = Relay (–) Pin 4 also connects in series with the circuit to be switched at empty. 9

Summary of the content on the page No. 12

Table 1. Hour Meter Control Lines & Impedance Specifications Model Low Voltage High Voltage Min. Impedance Maximum Minimum HRM+ HRM- 24 VDC 5.0 VDC 15.0 VDC 90 k Ω 30 kΩ Table 2. Hour Meter Control Logic Key HRM HRM HRM Hour Icon switch (+) (+) (+) meter Off x x x Display onlySteady On V H xx On Flashing On x V H xOnFlashing On x V H x On Flashing On V V V L L L Display Flashing or open or open or open only ! 10

Summary of the content on the page No. 13

NOTE: Fuses and Wires Regulations may require that the Model 833 be ! fused. If installing a fuse, use a 10A fuse wired with 1.5mm or equivalent wire. The voltage drop across the fuse, its holder, and connectors must be less than 1% of the nominal system voltage. Discharge Adjustments Table 3 lists the voltages per cell under load that correspond to an empty indication on the gauge (lockout point). Table 3. Discharge Adjustment Settings Setting Volt/Cell at Empty K 1.57 L 1.63 M 1.

Summary of the content on the page No. 14

! CURTIS Model 833 Rear View 12

Summary of the content on the page No. 15

Connections for Typical Model 833 Application Vehicle system voltage is the higher of the two operating ! voltages of a dual voltage unit. Hour meter measures “keyswitch on” time. 13

Summary of the content on the page No. 16

4. OPERATION Display The Curtis Model 833 combines in one instrument a completely solid state LED battery state-of-charge indicator, an LCD hour meter, and lift lockout. Only when battery is properly charged is right most LED (1) lit. As battery’s state-of-charge decreases, successive LEDs light up, one at a time. 2nd from left LED flashes indicating “energy reserve” (70% discharged). The left most 2 LEDs flash indicating “empty” (80% depth of dis- charge). At this point, lift lockout o

Summary of the content on the page No. 17

Push-to-read When the front button is depressed, the LCD will display the hour meter reading for 6 seconds min. The hour meter will not accumulate time during this operation. Reset type/level (after or during recharge) CTR = Charge Tracking Reset If the gage is connected to the battery during recharge, the gage will track the battery charge level. OCR = Open Circuit Reset If the gage is disconnected from the battery during recharge, the gage will retain the last indication. It will advance t

Summary of the content on the page No. 18

5. Troubleshooting The following checklist should help you to troubleshoot any problems with the instrument. Problem Possible Causes No display Terminals not connected or improper voltage Stays at FULL Instrument voltage does not match battery voltage, B+ connected to the wrong terminal Will not reset Instrument voltage does not match battery voltage, or battery not fully charged Resets w/o charging battery Not connected directly to battery terminals EMPTY too soon B+ connected to wrong t

Summary of the content on the page No. 19

6. Maintenance Model 833 Series is not serviceable in the field. Units returned to the factory within the warranty period (see inside backcover) will be replaced without charge. 17

Summary of the content on the page No. 20

Guarantee - Curtis Instruments’ products and/or components are guaranteed against defects in workmanship and material for a period of two years, or as defined in the individual product literature, from date of shipment from our factory, when applied in a proper application within specified ratings. This guarantee is limited to repair or replacement F.O.B. our factory. There is no further warranty or implied representation, guarantee, promise or agreement as to any Curtis Instruments product an


Alternative user manuals
# User manual Category Download
1 Sony SSM-930 User manual Marine Instruments 3
2 Sony SSM-175A User manual Marine Instruments 0
3 Attwood 8M004689 User manual Marine Instruments 0
4 Attwood 99515-1 User manual Marine Instruments 0
5 Attwood 99510-1 User manual Marine Instruments 0
6 Attwood 99520-1 User manual Marine Instruments 0
7 Attwood 8M0044688 User manual Marine Instruments 0
8 Attwood 99540-1 User manual Marine Instruments 0
9 Attwood 99530-1 User manual Marine Instruments 0
10 Atari LC-1 User manual Marine Instruments 0
11 Atari LM-1 User manual Marine Instruments 2
12 ATD Tools atd-5608 User manual Marine Instruments 1
13 Central Hydraulics 94143 User manual Marine Instruments 1
14 Central Pneumatic Air Compressor 95583 User manual Marine Instruments 0
15 Chicago Electric 93801 User manual Marine Instruments 1