Teledyne 450 user manual

User manual for the device Teledyne 450

Device: Teledyne 450
Category: Marine Instruments
Manufacturer: Teledyne
Size: 0.62 MB
Added : 4/1/2014
Number of pages: 55
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 450. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 450.

For your convenience

If looking through the Teledyne 450 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 450 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 450 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 450 User manual - Online PDF
Advertisement
« Page 1 of 55 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 450 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 450. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



INSTRUCTION MANUAL


MODEL 450
OZONE MONITOR





© Teledyne Instruments
Advanced Pollution Instrumentation Division
(T-API)
9480 Carroll Park Drive
San Diego, CA 92121-5201

TOLL-FREE: 800-324-5190
TEL: 858-657-9800
FAX: 858-657-9816
EMAIL: api-sales@teledyne.com
WEB SITE: www.teledyne-api.com














02395
Rev D1
11/22/05

Summary of the content on the page No. 2

SAFETY MESSAGES Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described below: General Warning/Caution: Refer to the instructions f

Summary of the content on the page No. 3

TABLE OF CONTENTS SAFETY MESSAGES....................................................................................................................................II TABLE OF CONTENTS ...............................................................................................................................III FIGURES ........................................................................................................................................................V TABLES...........

Summary of the content on the page No. 4

5.1 CALIBRATION ...........................................................................................................................................47 5.2 ADJUSTING UV LAMP AND DETECTOR ......................................................................................................47 5.3 CHANGING THE ANALOG OUTPUT RANGE..................................................................................................49 5.3.1 Voltage output..........................................

Summary of the content on the page No. 5

FIGURES FIGURE 1.1 - REAR PANEL PNEUMATIC CONNECTIONS............................................................13 FIGURE 1.2 – NEMA 4X ENCLOSURE DIMENSIONS.......................................................................16 FIGURE 1.3 – NEMA 4X AC LINE POWER CONNECTION .............................................................17 FIGURE 1.4 – NEMA 4X FRONT PANEL..............................................................................................18 FIGURE 1.5 – NEMA 4X PNEU

Summary of the content on the page No. 6

TABLES TABLE 1.1 DIGITAL OUTPUTS..............................................................................................................21 TABLE 1.2 FINAL TEST AND CALIBRATION VALUES ...................................................................28 TABLE 2.1 SYSTEM MODES...................................................................................................................33 TABLE 2.2 TEST MEASUREMENTS....................................................................

Summary of the content on the page No. 7

1.0 INTRODUCTION 1.1 Preface Teledyne API is pleased that you have purchased the Model 450. We offer a full one year warranty (see Section 1.2) and we at Teledyne API will be pleased to provide you with any support required so that you may utilize our equipment to the fullest extent. The Teledyne API Model 450 keyboard/operator interface with its "talking keys" makes the Teledyne API a very user-friendly system. We hope you will not experience any problems with the Teledyne API Model

Summary of the content on the page No. 8

1.2 WARRANTY POLICY ADVANCED POLLUTION INSTRUMENTATION DIVISION (T-API) 02024b Prior to shipment, Teledyne API equipment is thoroughly inspected and tested. Should equipment failure occur, Teledyne API assures its customers that prompt service and support will be available. COVERAGE After the warranty period and throughout the equipment lifetime, Teledyne API stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry

Summary of the content on the page No. 9

TERMS AND CONDITIONS All units or components returned to Teledyne API should be properly packed for handling and returned freight prepaid to the nearest designated Service Center. After the repair, the equipment will be returned, freight prepaid. 1.3 Principle of Operation The detection of ozone molecules is based on absorption of 254 nm UV light due to an internal electronic resonance of the O molecule. The Model 450 uses a mercury lamp 3 constructed so that a large majority of the l

Summary of the content on the page No. 10

The intensity of light is converted into a voltage by the detector/preamp module. The voltage is converted into a number by a voltage-to-frequency (V/F) converter capable of 80,000 count resolution. The digitized signal, along with the other variables, are used by the CPU to compute the concentration using the above formula. Every 6 seconds the M450 completes a measurement cycle consisting of a 2 second wait period for the sample tube to flush, followed by a 1 second measurement of the

Summary of the content on the page No. 11

1.4 Specifications Ranges User selectable to any full scale range from 1ppm to 1000 ppm 3 3 Measurement Units ppbv, ppmv, ppmw, pphm, µg/m , mg/ m Zero Noise < .0015 ppm (rms) Span Noise < .5% of reading (rms) (above 0.1 ppm) Lower Detectable Limit < .003 ppm (rms) Linearity Better than 1% full scale Response Time (95%) <30 sec Minimum Stream Duration 1.0 min (Cycle Time)* Sample Flow Rate 1-2.5 L/min o Temperature Range 5-45 C Humidity Range 10-90% RH, Non-Condensing Dimensions

Summary of the content on the page No. 12

1.5 Installation (19” Rack Mount Enclosure) The Model 450 is shipped with the following standard equipment: 1. Power cord. 2. Instruction manual. CAUTION To avoid personal injury, always use two persons to lift and carry the Model 450. Upon receiving the Model 450 please do the following: 1. Verify no apparent shipping damage. (If damage has occurred please advise shipper first, then Teledyne API.) 2. Remove all red colored shipping screws from the inside and bottom o

Summary of the content on the page No. 13

CAUTION Verify that the instrument is set up for proper line voltage and frequency. 6. Turn on the M450 by switching the switch on the lower right corner of the front panel. The front panel display should light with a sequence of messages, -API - M450 - software version number, then a normal display as shown in Figure 2.2. 7. Allow about 20 minutes for the UV lamp temperature to come up to it’s setpoint then press the TST> button on the front keyboard to scroll through the TEST value

Summary of the content on the page No. 14

1.6 Installation (NEMA 4X, Wall Mount Enclosure) The Model 450 is shipped with the following standard equipment: 1. Instruction manual. CAUTION To avoid personal injury, always use two persons to lift and carry the Model 450. Upon receiving the Model 450 please do the following: 1. Verify no apparent shipping damage. (If damage has occurred please advise shipper first, then Teledyne API.) 2. Mount the NEMA 4X enclosure to a vertical surface using four 5/16” bolts. Mountin

Summary of the content on the page No. 15

10. Allow about 20 minutes for the UV lamp temperature to come up to it’s setpoint then press the TST> button on the front keyboard to scroll through the TEST values. Compare these values to those noted during the final factory checkout listed in Table 1.2. The values observed should closely match the Table 1.2 values. P/N 02395D1 Teledyne API Model 450 O Monitor Instruction Manual - Page 15 3

Summary of the content on the page No. 16

FIGURE 1.2 – NEMA 4X ENCLOSURE DIMENSIONS P/N 02395D1 Teledyne API Model 450 O Monitor Instruction Manual - Page 16 3

Summary of the content on the page No. 17

FIGURE 1.3 – NEMA 4X AC LINE POWER CONNECTION P/N 02395D1 Teledyne API Model 450 O Monitor Instruction Manual - Page 17 3

Summary of the content on the page No. 18

FIGURE 1.4 – NEMA 4X FRONT PANEL P/N 02395D1 Teledyne API Model 450 O Monitor Instruction Manual - Page 18 3

Summary of the content on the page No. 19

FIGURE 1.5 – NEMA 4X PNEUMATIC CONNECTIONS P/N 02395D1 Teledyne API Model 450 O Monitor Instruction Manual - Page 19 3

Summary of the content on the page No. 20

FIGURE 1.6 - ELECTRICAL SIGNAL CONNECTIONS 1.7 Electrical and pneumatic connections 1.7.1 Analog Output The analog output is a two pin connector on the rear panel (See Figure 1.6). The analog output can be configured for voltage or current output. The standard is a 0-5 volt output. 0-100mV, 0-1V, 0-10V, and 4-20 mA outputs are also available. See Section 5.3 for information on setting other output ranges. 1.7.2 Relay Outputs Three form C relay outputs are provided on the rea


Alternative user manuals
# User manual Category Download
1 Teledyne 2002 User manual Marine Instruments 1
2 Teledyne 322 User manual Marine Instruments 0
3 Teledyne HCM-300 User manual Marine Instruments 0
4 Teledyne 5499 User manual Marine Instruments 0
5 Teledyne HPM 4/6 User manual Marine Instruments 13
6 Teledyne 465L User manual Marine Instruments 1
7 Teledyne 760 PLUS User manual Marine Instruments 0
8 Sony SSM-930 User manual Marine Instruments 3
9 Sony SSM-175A User manual Marine Instruments 0
10 Attwood 8M004689 User manual Marine Instruments 0
11 Attwood 99515-1 User manual Marine Instruments 0
12 Attwood 99510-1 User manual Marine Instruments 0
13 Attwood 99520-1 User manual Marine Instruments 0
14 Attwood 8M0044688 User manual Marine Instruments 0
15 Attwood 99540-1 User manual Marine Instruments 0