Alto-Shaam 6.10 user manual

User manual for the device Alto-Shaam 6.10

Device: Alto-Shaam 6.10
Category: Microwave Oven
Manufacturer: Alto-Shaam
Size: 2.79 MB
Added : 3/4/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Alto-Shaam 6.10. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Alto-Shaam 6.10.

For your convenience

If looking through the Alto-Shaam 6.10 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Alto-Shaam 6.10 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Alto-Shaam 6.10 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Alto-Shaam 6.10 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Alto-Shaam 6.10 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Alto-Shaam 6.10. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

C o m b i n a t i o n
O v e n / S t e a m e r
ES ELECTRIC
SERIES
6•10
10•10
7•14
10•18
12•20
20•20
VHES-5
VHES-10
INSTALLATION
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744 USA/CANADA FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY
WWW.ALTO-SHAAM.COM
#MN-28677 • 08/08
PRINTED IN U.S.A.

Summary of the content on the page No. 2

General Information Delivery / Unpacking . . . . . . . . . . . . . . . . . .1. Safety Procedures and Precautions . . . . . . . . .2. Specifications Options . . . . . . . . . . . . . . . . . . . . . . . . . . .3. 6•10es . . . . . . . . . . . . . . . . . . . . . . . . . . . .4. 6•10esi . . . . . . . . . . . . . . . . . . . . . . . . . . .5. 6•10esiN . . . . . . . . . . . . . . . . . . . . . . . . . .6. 10•10es . . . . . . . . . . . . . . . . . . . . . . . . . . .7. 10•10esi . . . . . . . . . . . .

Summary of the content on the page No. 3

® ® D E L I V E RY U N PA C K I N G 1. Carefully remove the This Alto-Shaam appliance has been appliance from the thoroughly tested and inspected to insure only the carton or crate. highest quality unit is provided. Upon receipt, check for any possible shipping damage and report NOTE: Do not discard the it at once to the delivering carrier. See carton and other Transportation Damage and Claims section packaging material located in this manual. until you have This appliance, complete with unattac

Summary of the content on the page No. 4

SAFETY PROCEDURES AND PRECAUTIONS Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold or safe operation of electrically and/or gas energized process foods for the purpose of human equipment. In accordance with generally accepted consumption. No other use for this appliance is product safety labeling guidelines for potential authorized or recommended. hazards, the following signal words and symbols 2. This appliance is intended for use in commercial may

Summary of the content on the page No. 5

COMMON SPECIFICATIONS ® COMBITHERM   CombiGuard™ Triple-Guard Water Filtration System (INCLUDES 1 CARTRIDGE) FI-23014   CombiGuard™ Replacement Filter FI-26356   Fry Basket, 12" X 20" (325mm x 530mm) BS-26730   Grilling Grate, 12" X 20" (325mm x 530mm) SH-26731   Oven Cleaner — CE-24750 SPECIALLY FORMULATED FOR COMBITHERM OVENS Six (6) Chicken Roasting Rack  TWELVE (12) CONTAINERS/CASE, 1 QUART (C. 1 LITER) EACH (PAN NOT INCLUDED) SH-23000   Scale Free™ CE-27889 (CITRUS BASED

Summary of the content on the page No. 6

6•10 ES SPECIFICATIONS ® COMBITHERM 30" (761mm) 43-7/8" (1114mm) 34-1/16" (864mm) Water Drain 2-3/16" (56mm) (Side Back) 41-15/16" (1064mm) 31-3/8" (796mm) 4-3/4" (120mm) Decalcification Port Untreated Water Intake (Bottom) WATER Treated Water DRAIN Intake (Bottom) Electrical Connection (Bottom) 2" (50mm) 4-15/16" 7-9/16" 17-15/16" 33-1/8" (840mm) (125mm) (191mm) (456mm) DIMENSIONS: H x W x D 49-1/8" (1247mm) EXTERIOR: INSTALLATION REQUIREMENTS 35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm

Summary of the content on the page No. 7

® 6•10 ESi SPECIFICATIONS COMBITHERM 30" (761mm) 43-7/8" (1114mm) 34-1/16" (864mm) Water Drain 2-3/16" (56mm) (Side Back) 41-15/16" (1064mm) 31-3/8" (796mm) 4-3/4" (120mm) Untreated Water Intake (Bottom) Low Pressure WATER Valve (Top) Treated Water DRAIN Intake (Bottom) Electrical Connection (Bottom) 2" (50mm) 4-15/16" 7-9/16" 17-15/16" 33-1/8" (840mm) (125mm) (191mm) (456mm) DIMENSIONS: H x W x D 49-1/8" (1247mm) EXTERIOR: INSTALLATION REQUIREMENTS 35-3/16" x 43-7/8" x 34-1/16" (893mm x

Summary of the content on the page No. 8

® 6•10 ESiN SPECIFICATIONS COMBITHERM 21-7/8" (555mm) Water Drain 2-3/16" (55mm) 35-9/16" (903mm) 35-13/16" (909mm) (Side Back) 32-15/16" (835mm) 4-3/4" (120mm) 33-7/8" (859mm) Steam Vent Untreated Water (Top) Intake (Bottom) Low Pressure Valve WATER Treated Water DRAIN Intake (Bottom) Electrical Connection (Bottom) 2" (50mm) 7-1/2" 19-9/16" 25" 5" (190mm) (496mm) (635mm) (126mm) 41-1/16" (1042mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 35-3/16" x 35-13/16" x 35-9/16" (893

Summary of the content on the page No. 9

10•10 ES SPECIFICATIONS ® COMBITHERM 30" (761mm) 3-3/16" (80mm) Water Drain 43-7/8" (1114mm) 34-1/16" (865mm) (Back Side) 4-3/4" (120mm) 41-15/16" (1064mm) 31-3/8" (796mm) Decalcification Port Untreated Water Intake (Bottom) Treated Water Intake (Bottom) Water Drain Electrical Connection (Bottom) 2" (50mm) 33-1/16" (840mm) 4-15/16" (125mm) 7-9/16" 17-15/16" (191mm) (456mm) DIMENSIONS: H x W x D 46-7/8" (1190mm) EXTERIOR: INSTALLATION REQUIREMENTS 41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x

Summary of the content on the page No. 10

® 10•10 ESi SPECIFICATIONS COMBITHERM 30" (761mm) Water Drain 2-3/16" (56mm) 43-7/8" (1114mm) 34-1/16" (865mm) (Back Side) 4-3/4" (120mm) 41-15/16" (1064mm) 31-3/8" (796mm) Untreated Water Intake (Bottom) Low Pressure Valve (Top) Treated Water Intake (Bottom) Water Drain Electrical Connection (Bottom) 2" (50mm) 33-1/16" (840mm) 4-15/16" (125mm) 7-9/16" 17-15/16" (191mm) (456mm) 46-7/8" (1190mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 41-1/2" x 43-7/8" x 34-1/16" (1053mm x 11

Summary of the content on the page No. 11

10•10 ESiN SPECIFICATIONS ® COMBITHERM 21-15/16" (557mm) 35-7/8" (910mm) 2-3/16" (55mm) 35-11/16" (905mm) Water Drain 33-7/8" (860mm) 4-3/4" (120mm) (Side Back) 33" (837mm) Steam Untreated Water Intake Vent (Bottom) (Top) Low Pressure Valve Treated Water WATER Intake (Bottom) DRAIN Electrical Connection(Bottom) 2" (50mm) 7-9/16" 19-9/16" 25" 5" (126mm) (635mm) (191mm) (496mm) 41-1/16" (1043mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 41-3/8" x 35-7/8" x 35-11/16" (1050mm x 9

Summary of the content on the page No. 12

® 7•14 ES SPECIFICATIONS COMBITHERM 2-5/16" (58mm) 4-11/16" (120mm) Decalcification Port FRONT VIEW SIDE VIEW DIMENSIONS: H x W x D Helvetica TOP VIEW Light Condensed EXTERIOR: INSTALLATION REQUIREMENTS 8 pt 34-1/4" x 43-7/8" x 42-13/16" (869mm x 1114mm x 1087mm) Oven must be installed level. EXTERIOR WITH RETRACTABLE DOOR: Hood installation is required. 34-1/4" x 47-7/8" x 42-13/16" (869mm x 1216mm x 1087mm) Water supply shut-off valve and back-flow INTERIOR: preventer. 20-5/16" x 23-1/2" x

Summary of the content on the page No. 13

7•14 ESi SPECIFICATIONS ® COMBITHERM 2-5/16" (58mm) 4-11/16" (120mm) Low Pressure Valve FRONT VIEW SIDE VIEW DIMENSIONS: H x W x D Helvetica TOP VIEW EXTERIOR: Light Condensed INSTALLATION REQUIREMENTS 8 pt 34-1/4" x 43-7/8" x 42-13/16" (869mm x 1114mm x 1087mm) Oven must be installed level. EXTERIOR WITH RETRACTABLE DOOR: Hood installation is required. 34-1/4" x 47-7/8" x 42-13/16" (869mm x 1216mm x 1087mm) Water supply shut-off valve and back-flow INTERIOR: preventer. 20-5/16" x 23-1/2" x

Summary of the content on the page No. 14

® 10•18 ES SPECIFICATIONS COMBITHERM 43-7/8" 30" 42-13/16" (1114mm) (760mm) (1087mm) 4-11/16" (120mm) Water Drain 41-15/16" Decalcification 40-1/8" 2-5/16" (58mm) (1064mm) (Side Back) (1019mm) Port Steam Vents Untreated Water (Top) Intake (Bottom) Treated Water Intake (Bottom) Water Drain (Bottom) Electrical Connection (Bottom) 25-5/8" (650mm) 33-1/8" 4-15/16" 8-11/16" (840mm) (125mm) (219mm) 2" (50mm) 46-7/8" (1190mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 40-7/16" x 43-7/8"

Summary of the content on the page No. 15

® 10•18 ESi SPECIFICATIONS COMBITHERM 43-7/8" 30" 42-13/16" (1114mm) (760mm) (1087mm) 4-11/16" (120mm) 41-15/16" Water Drain 40-1/8" 2-5/16" (58mm) (1064mm) (Side Back) (1019mm) Steam Untreated Water Vents Intake (Bottom) (Top) Low Pressure Valve (Top) Treated Water Intake (Bottom) Water Drain (Bottom) Electrical Connection (Bottom) 25-5/8" (650mm) 33-1/8" 4-15/16" 8-11/16" (840mm) (125mm) (219mm) 2" (50mm) 46-7/8" (1190mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 40-7/16" x 4

Summary of the content on the page No. 16

® 12•20 ES SPECIFICATIONS COMBITHERM 6-11/16" 46-3/4" (169mm) 48" 11-7/8" (1186mm) (1218mm) 4-1/4" (302mm) 44-3/4" (106mm) Water Drain 45-5/16" (1136mm) (Side Back) (1151mm) Untreated Water Steam Intake Vents (Bottom) (Top) Treated Water Water Drain Intake (Bottom) (Bottom) Electrical Connection (Bottom) 2" (50mm) 33-1/2" 40-15/16" 1-13/16" (851mm) (1039mm) (46mm) 2-1/16" (52mm) 51-15/16" (1319mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 54-3/8" x 46-3/4" x 48" (1381mm x 11

Summary of the content on the page No. 17

® 20•20 ES SPECIFICATIONS COMBITHERM 46-3/4" 11-7/8" 48" 5" (127mm) (1186mm) (302mm) (1218mm) 4-3/4" Water Drain 44-3/4" 45-5/16" (120mm) (Side Back) (1136mm) (1151mm) Steam Electrical Vents Connection (Bottom) (Top) Untreated Water Intake (Bottom) Treated Water Intake (Bottom) Water Drain 2" (50mm) (Bottom) 33-1/2" 51-15/16" (1319mm) (851mm) 40-15/16" 1-13/16" 2-1/16" (52mm) (1039mm) (46mm) DIMENSIONS: H x W x D EXTERIOR: INSTALLATION REQUIREMENTS 76-1/4" x 46-3/4" x 48" (1936mm x 1186mm x

Summary of the content on the page No. 18

® ® LOCATION SITE & INSTALLATION REQUIREMENTS COMBITHERM DANGER DANGER IMPROPER INSTALLATION, AVERTISSEMENT : UNE INSTALLATION, ALTERATION, ADJUSTMENT, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICE OU UN ENTRETIEN NON SERVICE, OR MAINTENANCE COULD CONFORME AUX NORMES PEUT CAUSER RESULT IN SEVERE INJURY, DEATH DES DOMMAGES À LA PROPRIÉTÉ, DES OR CAUSE PROPERTY DAMAGE. BLESSURES OU LA MORT. READ THE INSTALLATION, OPERATING AND MAINTENANCE LIRE ATTENTIVEMENT LES DIRECTIVES INSTRUCTIONS THOROUGHLY D’O

Summary of the content on the page No. 19

LOCATION SITE & INSTALLATION REQUIREMENTS ® ® COMBITHERM VENTILATION REQUIREMENTS CAUTION A steam ventilation hood is mandatory for the TO PREVENT PERSONAL INJURY, operation of the oven. The ventilation hood must be installed in accordance with local building USE CAUTION WHEN MOVING OR codes for the steam exhaust and must protrude LEVELING THIS APPLIANCE. 12-inches to 20-inches (300 to 500mm) over the front side of the oven. A grease filter must be located in the protruding area of the hood.

Summary of the content on the page No. 20

® ® LOCATION SITE & INSTALLATION REQUIREMENTS COMBITHERM POSITIONING REQUIREMENTS  In order to ensure proper ventilation, a minimum distance of at least 6-inches (152mm) must be kept from the control panels side (left) of the oven and any adjoining surfaces. NOTE: Additional clearance is needed for service access. A minimum distance of 18-inches is strongly recommended. If adequate service clearance is not provided, it will be necessary to disconnect the gas, water, and drain to move the ov


Alternative user manuals
# User manual Category Download
1 Alto-Shaam COMBITHERM MN-29249RU User manual Microwave Oven 1
2 Alto-Shaam COOKING & HOLDING OVEN AS-250 User manual Microwave Oven 7
3 Alto-Shaam COMBITOUCH 7.14ES User manual Microwave Oven 0
4 Alto-Shaam Low Temperature Cook & Hold Oven 750-TH-II User manual Microwave Oven 3
5 Alto-Shaam COMBITOUCH 7.14ESG User manual Microwave Oven 2
6 Alto-Shaam HALO HEAT 2800-SK/III User manual Microwave Oven 2
7 Alto-Shaam HALO HEAT 1767-SK/III User manual Microwave Oven 0
8 Alto-Shaam 610 User manual Microwaves 0
9 AEG MC1751E User manual Microwave Oven 346
10 AEG MC2662E User manual Microwave Oven 233
11 AEG MC1751E User manual Microwave Oven 202
12 AEG MC1763E User manual Microwave Oven 456
13 AEG MCD2661EM User manual Microwave Oven 156
14 AEG EMS26415X User manual Microwave Oven 20
15 AEG MC1761E User manual Microwave Oven 342