Summary of the content on the page No. 1 
                    
                        TM
SNC 5100 for the 
Scalar ® 1000 and 10K
User Guide                                                                                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    Summary of the content on the page No. 2 
                    
                        Copyright Notice © Copyright ADIC 2002 The information contained in this document is subject to change without notice. This document contains proprietary information which is protected by copyright. All rights are reserved. No  part of this document may be photocopied, reproduced, or translated to another language without prior written  consent of ADIC. ADIC shall not be liable for errors contained herein or for incidental or consequential damages (including lost  profits) in connection with the
                    
                    Summary of the content on the page No. 3 
                    
                        SNC 5100 Notices Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Remove AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Summary of the content on the page No. 4 
                    
                        SNC 5100 SCSI 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 PWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 RDY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 ERR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
                    
                    Summary of the content on the page No. 5 
                    
                        SNC 5100 Maintenance Action Plans Event Codes and Actions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Check Event Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Action Reference Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 Event Viewing Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Summary of the content on the page No. 6 
                    
                        SNC 5100 Examine Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Fibre Channel Loop Back Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Testing Fibre Channel Optical Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 Replace Fibre Channel Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 Replace Fibre Channel 
                    
                    Summary of the content on the page No. 7 
                    
                        SNC 5100 Connecting to the Service Port Service Port Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 Connecting the Service Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96 Hardware Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96 Initial Setup of HyperTerminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Summary of the content on the page No. 8 
                    
                        SNC 5100 POST Error Codes POST Boot Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197 ROM Init . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197 Initial POST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198 Simple Access Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Summary of the content on the page No. 9 
                    
                        SNC 5100 Notices Welcome ADIC is the leading expert in open systems data storage solutions.  Your new SNC 5100 is an intelligent storage networking appliance. It provides  a management platform for any-to-any connectivity, increases interoperability,  integrates protocol-aware services, and improves reliability, security, and  manageability in the Storage Area Network (SAN).  This manual is intended to provide hardware and firmware reference support  for ADIC customers and professional services 
                    
                    Summary of the content on the page No. 10 
                    
                        SNC 5100  Remove AC Power If the SNC 5100 is not powered off, perform the following steps to remove AC  power. Step 1. Perform a controlled system shutdown of attached host systems. Step 2. Set the Power switch on the SNC 5100 to the off position. Step 3. Disconnect the power cord from the power source. External Machine Check Perform the following external machine check: Step 1. Verify that the external cover and front bezel of the unit are present  and not damaged. Step 2. Check the power cord 
                    
                    Summary of the content on the page No. 11 
                    
                        SNC 5100 Step 2. Check the voltage label on the bottom of the device to ensure it  matches the voltage at the power source. Step 3. Check the voltage level at the power source. Fusing Requirements The SNC 5100 power supply has a 3.15 A, 250 VAC time delay fuse on the AC  line input, and the AC harness uses an axial lead, 3A, 250 VAC time delay fuse  in the neutral line. There are no user-serviceable parts in the SNC 5100. Environmental Notices and Statements Product Recycling This unit contains 
                    
                    Summary of the content on the page No. 12 
                    
                        SNC 5100  General Restrictions The classification is valid only if the module is operated within the specified  temperature and voltage limits. The system using the module must provide  power supply protection that guarantees that the system power source will  cease to provide power if the maximum recommended operation limit or more  is detected on the +3.3 V/+5 V at the power source. The operating temperature  of the module must be in the temperature range given in the recommended  operating li
                    
                    Summary of the content on the page No. 13 
                    
                        SNC 5100 Properly shielded and grounded cables and connectors must be used in order to  meet FCC emission limits. ADIC is not responsible for any radio or television  interference caused by using other than recommended cables and connectors or  by unauthorized changes or modifications to this equipment. Unauthorized  changes or modifications could void the user’s authority to operate the  equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the  following two co
                    
                    Summary of the content on the page No. 14 
                    
                        SNC 5100  Properly shielded and grounded cables and connectors must be used in order to  reduce the potential for causing interference to radio and TV communications  and to other electrical or electronic equipment. Such cables and connectors are  available from ADIC authorized dealers. ADIC cannot accept responsibility  for any interference caused by using other than recommended cables and  connectors. VCCI Notice (Japan Only) BSMI Notice EN 55022 Compliance (Czech Republic Only) This device be
                    
                    Summary of the content on the page No. 15 
                    
                        SNC 5100 Pokud nenÌ na typovÈm ötitku poËÌtaËe uvedeno, ûe spad· do t¯Ìdy A podle  EN 55022, spad· automaticky do t¯Ìdy B podle EN 55022. Pro za¯ÌzenÌ  za¯azen· do t¯Ìdy A (ochrannÈ p·smo 30m) podle EN 55022 platÌ n·sledujÌcÌ.  Dojde-li k ruöenÌ telekomunikaËnÌch nebo jinych za¯ÌzenÌ, je uûivatel povinen  provÈst takov· opat¯enÌ, aby ruöenÌ odstranil. CE Notice  Marking by the  indicates compliance of this tape library to the EMC  (Electromagnetic Compatibility) directive of the European Communi
                    
                    Summary of the content on the page No. 16 
                    
                        SNC 5100  Documentation Although the material contained herein has been carefully reviewed, ADIC  does not warrant it to be free of errors or omissions. We reserve the right to  make corrections, updates, revisions, or changes to the information contained  herein.  Send e-mail to: techdocs@adic.com 8 Documentation 6-00020-02                                                                                                                                                                             
                    
                    Summary of the content on the page No. 17 
                    
                        SNC 5100 Introduction This chapter describes the SNC 5100. It provides the following information:  Overview  Configuration Support  Hardware Product Description and Features  Supported Platforms  Supported Devices  Operating Specifications Overview The SNC 5100 is a 1U high, half-rack width, AC powered storage networking  controller.  It is the interface between storage and Open System Host interfaces and  provides Fibre Channel to SCSI connectivity. One possible configuration is  illustra
                    
                    Summary of the content on the page No. 18 
                    
                        SNC 5100  Configuration Support The SNC 5100 provides two Fibre Channel interfaces. The FC interfaces are  configured with Giga Bit Interface Converter (GBIC) modules. In addition, the SNC 5100 has four Ultra2 SCSI interfaces. The Ultra2  interfaces are Low Voltage Differential (LVD).  See Figure 3. Figure 3 Configuration Detail Address Mapping The SNC 5100 maps addresses across and between these different interfaces  and preserves the persistency of the address maps across power ups of systems,
                    
                    Summary of the content on the page No. 19 
                    
                        SNC 5100 Hardware Product Description and Features This section describes the capabilities of the product and outlines some of the  key features of its interfaces.  An IBM 405GP 200 MHz processor, with integrated instruction and data  caches, and internal serial I/O and Ethernet interfaces.  An Intel 80303 100 MHz Processor, with integrated instruction and data  caches.  QLogic 23x0 Fibre Channel protocol chip  32 MB ECC protected SDRAM program memory.  128 MB ECC protected SDRAM data buffe
                    
                    Summary of the content on the page No. 20 
                    
                        SNC 5100  Cables should have a duplex SC connector on the GBIC end and a connector  appropriate to the HBA in use on the host end.  Fibre Channel interfaces support the following Public and Private Loop modes:  Target  Initiator  Target and Initiator The maximum number of initiators connected via Fibre Channel is 64 per  Fibre Channel port.  Fibre Channel Interfaces also support the following connection options:  Loop  Point-to-Point  Loop Preferred The Fibre Channel controller is complian