Advantech Data Acquisition Modules ADAM 4000 user manual

User manual for the device Advantech Data Acquisition Modules ADAM 4000

Device: Advantech Data Acquisition Modules ADAM 4000
Category: Network Card
Manufacturer: Advantech
Size: 4.19 MB
Added : 6/1/2013
Number of pages: 429
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Advantech Data Acquisition Modules ADAM 4000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Advantech Data Acquisition Modules ADAM 4000.

For your convenience

If looking through the Advantech Data Acquisition Modules ADAM 4000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Advantech Data Acquisition Modules ADAM 4000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Advantech Data Acquisition Modules ADAM 4000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Advantech Data Acquisition Modules ADAM 4000 User manual - Online PDF
Advertisement
« Page 1 of 429 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Advantech Data Acquisition Modules ADAM 4000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Advantech Data Acquisition Modules ADAM 4000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ADAM 4000

Data Acquisition Modules
User's Manual



























Summary of the content on the page No. 2

ADAM 4000 Series Data Acquisition Modules User’s Manual Copyright Notice This document is copyrighted, 1997, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd., reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manu

Summary of the content on the page No. 3

Table of Contents Chapter 1 Introduction ..….....……..................…..................…….. 1-1 1.1 Overview .......................…................................….........….…… 1-2 1.2 Applications ..................….........................…….............…....... 1-4 Chapter 2 Installation Guideline ...................….................…....... 2-1 2.1 System Requirements to set up an ADAM network ..…....... 2-2 2.2 Basic configuration and hook-up ....................

Summary of the content on the page No. 4

3.17 ADAM-4056SO 12-ch. Source Type Isolated Digital Output Module ………….…………………………………………..……... 3-63 3.18 ADAM-4060/4068 Relay Output Module ................…........... 3-65 3.19 ADAM-4069 8-channel Relay Output Module ………………. 3-69 3.20 ADAM-4080/4080D Counter/Frequency Input Modules ….. 3-72 Chapter 4 Command Set ..................................................…......... 4-1 4.1 Introduction.................................................................….......... 4-2 4

Summary of the content on the page No. 5

Chapter 8 Calibration ...........................................…..................... 8-1 8.1 Analog Input Module Calibration ............................…........... 8-2 8.2 Analog Input Resistance Calibration .................................... 8-5 8.3 Analog Input Thermistor module Calibration ....................… 8-7 8.4 Analog Output Calibration ..................................................... 8-13 Appendix A Technical Specifications..............................….

Summary of the content on the page No. 6

B.1.1 Engineering Units .............................................................…….......... B-2 B.1.2 Percent of FSR .................................................................…............. B-3 B.1.3 Twos complement hexadecimal .....................................……............ B-4 B.1.4 Ohms ..............................................................................……............ B-5 B.2 Analog Input Ranges.............................................…..............

Summary of the content on the page No. 7

Introduction 1

Summary of the content on the page No. 8

Introduction 1.1 Overview The ADAM Series is a set of intelligent sensor-to-computer interface modules containing built-in microprocessor. They are remotely controlled through a simple set of commands issued in ASCII format and transmitted in RS-485 protocol. They provide signal conditioning, isolation, ranging, A/D and D/A conversion, data comparison, and digital communication functions. Some modules provide digital I/O lines for controlling relays and TTL devices. Software Configu

Summary of the content on the page No. 9

Chapter 1 The command set for input modules is larger because it incorporates alarm functions. All communications to and from the module are performed in ASCII, which means that ADAM modules can be virtually programmed in any high-level language. RS-485 Network The RS-485 network provides lower-noise sensor readings, as modules can be placed much closer to the source. Up to 256 ADAM modules may be connected to an RS-485 multi-drop network by using the ADAM RS-485 repeater which exten

Summary of the content on the page No. 10

Introduction ADAM modules can be mounted on any panels, brackets, or DIN rails. They can also be stacked together. The RS-485 network, together with screw-terminal plug connectors, allows for system expansion, reconfiguration, and repair without disturbing field wiring. Protection against the environment Since all the configurations are controlled by software, the protection provided by the packaging is very important. The plastic outer shell enhances resistance against corrosive ma

Summary of the content on the page No. 11

Installation Guideline 2

Summary of the content on the page No. 12

Installation Guideline This chapter provides guidelines to what is needed to set up and install an ADAM network. A quick hookup scheme is provided that lets you configure modules before they are installed in a network. To help you connect ADAM modules with sensor inputs, several wiring examples are provided. At last, you will find a programming example using the ADAM command set at the end of this chapter. Be sure to plan the layout and configuration of your network carefully befor

Summary of the content on the page No. 13

Chapter 2 Power supply For the ease of use in industrial environments, the ADAM modules are designed to accept industry standard +24 V , unregulated power. DC Operation is guaranteed when using any power supply between +10 and +30 V . Power ripples must be limited to 5 V peak to peak while the DC voltage in all cases must be maintained between +10 and +30 V . All DC power supply specifications are referenced at module connector. When modules are powered remotely, the effects of DC v

Summary of the content on the page No. 14

Installation Guideline Figure 2-1 Power Supply Connections We advise the following standard colors (as indicated on the modules) for each power line: +Vs (R) Red GND (B) Black Communication Wiring We recommend the use of shielded-twisted-pair cable in the ADAM network for reducing interference purpose, but the cable has to comply with the EIA RS-485 standard. Furthermore, only one set of twisted- pair cable is required for transmitting Data. We advise the following standard c

Summary of the content on the page No. 15

Chapter 2 Notice: User can refer our help file to see more details for explanation of Utility operation. ADAM Communication Speed In ADAM series, the baud rate can be configured from 1200 bps to 38.4 Kbps. However, the baud rate of all modules in an RS-485 network must be the same. ADAM Isolated RS-232/RS485 Converter (optional): ADAM-452x When the host computer or terminal only has a RS-232 port, an ADAM Isolated RS-232/RS-485 Converter is required. Since this module is n

Summary of the content on the page No. 16

Installation Guideline 2.2 Basic configuration and hook-up Before placing a module in an existing network, the module should be configured. Though all modules are initially configured at the factory, it is recommended to check if the baud rate is set correctly beforehand. Default Factory Settings Baud rate: 9600 Bit/sec. Address: 01 (hexadecimal) The basic hook-up for module configuration is shown below. Figure 2-2 Basic Hook-up of ADAM Module to Host Switches 2-6 AD

Summary of the content on the page No. 17

Chapter 2 The following items are required to configure a module: an ADAM converter module, a personal computer with RS-232 port (baud rate set to 9600) and the ADAM utility software. Configuration with the ADAM Utility Software The easiest way to configure the ADAM module is by using the ADAM utility software. It is a user friendly structured menu program that will guide you through every step of the configuration. (See Appendix D, Utility Software) Changing the protocol from ADAM A

Summary of the content on the page No. 18

Installation Guideline Module at address 01 responds that it is configured for an input range of +/-2.5 V, baud rate of 9600, integration time of 50 ms (60 Hz). The code also shows engineering units and no checksum checking or generation. To change the configuration setting of the analog input module, the following command is issued: %01070F0600(cr) % = change configuration 01 = target module at address 00 to: 07 = change address to 07 hexadecimal 0F = set input range

Summary of the content on the page No. 19

Chapter 2 2.3 Baud rate and Checksum ADAM modules contain EEPROMs to store configuration information and calibration constants. The EEPROM replaces the conventional array of switches and pots that are originally used for specifying baud rate, input and output range… etc. Since there is no visual indication of a module’s configuration status, it is impossible to know the baud rate, address and other settings just by looking at it. It might not be possible to establish communications

Summary of the content on the page No. 20

Installation Guideline • Power on all components except the ADAM Module. • Power the ADAM module on while shorting the INIT* and GND terminals (See Figure 2-3) or set the INIT switch to “Init” (See Figure 2-4) Figure 2-3 Grounding the INIT* Terminal Figure 2-4 Set INIT switch to “Init” • Configure the checksum status and/or the baud rate. • Switch the power OFF to the ADAM Module. • Remove the grounding of the INIT* terminal and turn on the module, or set the INIT switch t


Alternative user manuals
# User manual Category Download
1 Advantech ADAM-4500 User manual Network Card 9
2 Advantech Network Device USB-4761 User manual Network Card 6
3 Advantech EKI-2525P User manual Network Card 33
4 Advantech PC-LabCard PCI-1784 User manual Network Card 9
5 Advantech USB-4750 User manual Network Card 40
6 Advantech PCE-5120 User manual Network Card 9
7 Advantech PCL-849 User manual Network Card 2
8 Advantech 5000 Series User manual Network Card 12
9 Sony BTA-NW1A User manual Network Card 2
10 Sony BKMW-E3000 User manual Network Card 2
11 Sony AC-SQ950D User manual Network Card 0
12 Sony BBV RX100 User manual Network Card 3
13 Sony CLIE A-AVZ-100-11 User manual Network Card 1
14 Sony BTA-NW1 User manual Network Card 11
15 Sony AC-NWUM50 User manual Network Card 1