Gossen R2600 user manual

User manual for the device Gossen R2600

Device: Gossen R2600
Category: Network Card
Manufacturer: Gossen
Size: 0.17 MB
Added : 8/23/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Gossen R2600. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Gossen R2600.

For your convenience

If looking through the Gossen R2600 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Gossen R2600 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Gossen R2600 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Gossen R2600 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Gossen R2600 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Gossen R2600. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Interface description
R2600 / R2601
3-348-815-15
6/11.03
DIN Draft 19244 Interface

Summary of the content on the page No. 2

Summary of the content on the page No. 3

CONTENTS Page Page 1 General ...................................................................................... 4 4 Parameter indices of the equipment parameters ........................ 24 1.1 Interface hardware ............................................................. 4 4.1 Temperature parameters ................................................. 24 1.2 Communications protocol ................................................... 4 4.2 Control parameters ..................................

Summary of the content on the page No. 4

GOSSEN METRAWATT GMBH 4 1 General 1.1 Interface hardware To communicate with a host computer, an SPS, etc., the controllers R2600 / 01 must be equipped with marking F1. In this case, the controllers are equipped with a serial interface having the following data: • Level types RS-232 and RS-485 (two-wire) in the unit selectable • Baud rate 9600 bd • Character format 8 data bits, 1 parity bit, 1 stop bit • Parity Even • Maximum number of equipment on the bus: 32 • With RS-485 bus operation, each

Summary of the content on the page No. 5

1.3 How to connect the interface 1.3.1 RS-232 connection When using the a RS-232 interface, only one R2600/01 can be connected to a master (e.g. PC), for example, for pre-loading the unit with user-specific data. Sub-D socket R2600/01 Number 25 9 of pins: DCD 8 1 RxD 3 2 20 TxD TxD 2 3 21 RxD DTR 20 4 Gnd 7 5 19 Gnd DSR 6 6 RTS 4 7 CTS 5 8 Depending upon the driver software, the jumpers on the master side can be omitted and/or can be different. GOSSEN METRAWATT GMBH 5

Summary of the content on the page No. 6

GOSSEN METRAWATT GMBH 6 1.3.2 RS-485 connection When using a RS-485 interface, as many as 32 equipment (R2600/01 and others) can be connected to the bus. Thereby, all terminals A, B and/or C are interconnected in parallel. The wiring must be made from equipment to equipment and must not be a star con- nection. With longer bus lines (longer than about 5 m) the bus should be terminated at both ends with the characteristic impedance (e.g. 200 Ω between A and B). Master R2600/01 R2600/01 A 21 21 B

Summary of the content on the page No. 7

Following, the master may only become active again, when – it receives a reply telegram from the addressed equipment and the specified wait time after a reply telegram (t aw) has elapsed, or – the maximum specified response delay time (t av) has elapsed. Within a telegram, pauses of limited duration (t zv = character delay time) may occur between 2 character transmissions. 1.5 Time action Ready to send/receive after turn-on t ber approx. 5 s Character delay time (R2600 transmitter) t zvs<3ms Cha

Summary of the content on the page No. 8

GOSSEN METRAWATT GMBH 8 2 Telegram structure All telegrams consist of one of 3 sets in both request and reply direction, they differ in their principal structure. Their use is fixed for each interface function of the R2600/01. Structure and use of the set types are described as follows. 2.1 Short set Short sets are used on the request side (from the master) • for transmission of short instructions to the equipment (e.g. Reset) • for short requests of important data from the equipment (e.g. even

Summary of the content on the page No. 9

2.2 Control set The R2600/01 uses control sets on the request side only. They serve to request all equipment data that cannot be requested via a short set because a detailed specification is required for them. Principal construction control set Character No. Contents Meaning Remarks 1 68h Start character 2 3 and/or 6 Length Number of characters from equipment address to checksum exclusive 3 3 and/or 6 Length (repeat) 4 68h Start character (repeat) 5 0 ... FAh, FFh Equipment address Addr and/or

Summary of the content on the page No. 10

GOSSEN METRAWATT GMBH 10 2.3 Long set The R2600/01 uses long sets to transmit instructions and parameters to the equipment and to receive data from the equipment. Principal construction long set Character No. Contents Meaning Remark 1 68h Start character 2 Length Number of characters from equipment address to checksum exclusive 3 Length (repeat) 4 68h Start character (repeat) 5 0 ... FAh, FFh Equipment address Addr and/or 255 (see 2.4.1) 6 Function field (FF) see 2.4.2. 1) 7 see 2.4.3. Paramet

Summary of the content on the page No. 11

2.4 Function and value range of the format characters 2.4.1 Equipment address • 0 ... 250 Range for individual equipment addresses = interface address Addr • 255 All equipment connected to a bus can simultaneously be addressed under this address. Data and instructions entered with this address are accepted by all equipment, but there is no acknowledgement made to the master. 2.4.2 Function field (FF) The function field contains • with the short set the proper user information, predefined by bit

Summary of the content on the page No. 12

GOSSEN METRAWATT GMBH 12 2.4.2.2 Function coding of the function field (FF) in response direction Bit No. Function Value Meaning 0 ... 2 Reserved 0, 0, 0 (fixed) 3 Request disable 0 Instruction executed, equipment ready 1 Equipment not ready for this instruction, eventually repeat instruction 4 Instruction acknowledgement 0 Instruction executed, equipment ready 1 Instruction could not be executed, equipment ready 5 Transmission error 0 Request telegram correct 1 Request telegram incorrect 6 Not

Summary of the content on the page No. 13

2.4.3 Parameter index (PI) The type of the data to be transmitted is defined via the parameter index. The "PI" character is interpreted as follows: Bit 7-4 Bit 3-0 0 ... Fh 0 ... Fh Selection number for main parameter group Selection number for a special parameter in the main group Functionally used data and/or setting parameters of an equipment are combined in the main parameter groups. Only those parameter indices docu- mented in section 4 can be addressed in the R2600/01, an error message is

Summary of the content on the page No. 14

GOSSEN METRAWATT GMBH 14 2.5 Criteria for the validity of a request telegram The R2600/01 checks the characters of the telegrams received in accordance with the following tables: For short set: For control and long set: Character No. Criterion Character No. Criterion 1 10h 1 68h 2 Interface address Addr or 255 (see 2.4.2) 2 Note length for PS and end character 3 FF = valid function coding 3 Character 3 = character 2 4 PS = Addr or 255 + FF 4 68h 5 16h 5 Interface address Addr or 255 6 FF = 69h o

Summary of the content on the page No. 15

3 Telegram contents R2600/01 3.1 Equipment reset The addressed equipment performs a hardware reset same as in the case of a short interruption of the auxiliary voltage. Example: Equipment address = 2 Request from master (short set): 10h 02h 09h 0Bh 16h FF PS R2600/01 response: None 3.2 Interrogation: Equipment OK? The addressed equipment shows the function field only: Example: Equipment address = 3 Request from master (short set): 10h 03h 29h 2Ch 16h FF PS R2600/01 response (short set): 10h 03h

Summary of the content on the page No. 16

GOSSEN METRAWATT GMBH 16 3.3 Request for cycle data You will get the most important measuring and output values of the controller in one data package. Cyclic requests of these values are thus made possible in compact form (short set request. Example: Equipment address = 2 Request from master (short set): 10h 02h 89h 8Bh 16h FF PS R2600/01 response (long set, see 2.3): 68h 09h 09h 68h 02h „FF“ Data block „PS“ 16h 7 characters See 2.4.2.2 for contents of the function field (FF) The 7 characters o

Summary of the content on the page No. 17

3.4 Request for event data The event date, combined in 2 words, contain all error messages and alarms of the equipment. They can be called up via short set to identify a special error. This request can be made asynchronous, for example, if the service request bit (collected errors) was set before in any random response telegram in the function field (FF). Example: Equipment address = 5 Request from master (short set): 10h 05h A9h AEh 16h R2600/01 response (long set, see 2.3): 68h 06h 06h 68h

Summary of the content on the page No. 18

GOSSEN METRAWATT GMBH 18 Character Bit No. Meaning Display on equipment Remark 0 Sensor breakage measuring circuit 2 1 Wrong polarity measuring circuit 2 2 Analog error 3 Sensor breakage measuring circuit 1 1. 4 Wrong polarity measuring circuit 1 5 Low limit 1 fallen below Associated 6 Low limit 2 fallen below data Status error display 7 High limit 1 exceeded word 1 flashes 8 High limit 2 exceeded (control loop) 1) 9 Impermissible parameter, see 2.5 10 1) 11 Error in heating circuit 2. 1)

Summary of the content on the page No. 19

0 Sensor error position readback 1 Sensor error heating current 2 3 3. 4 Heating current not "off" with positioning signal switched off Current display Heating current < 80 % of the set point of the heating current with flashes 5 active positioning signal Error status word 2 6 (heating 7 current 2) 8 EEPROM error monitor, 9 equipment) 10 Function error of rotary button 11 Error of measured value calibration 4. 12 13 Invalid combination of markings 14 15 1) These error bits are deleted afte

Summary of the content on the page No. 20

GOSSEN METRAWATT GMBH 20 3.5 Request data from R2600/01 This communication makes it possible to request all values, parameters, configurations, states and equipment markings. Thereby, the data is individually addressed per parameter index. See section 4 for the complete list of all parameter indices. 3.5.1 Request an equipment specification The parameter index lies between 30h and 3Fh. Thus the characters "from/to channel" and "receipt No." in the control and long set are omitted. Example: Requ


Alternative user manuals
# User manual Category Download
1 Gossen BD 232 User manual Network Card 0
2 Gossen SI 232-II User manual Network Card 2
3 Gossen R2601 User manual Network Card 17
4 Sony BTA-NW1A User manual Network Card 2
5 Sony BKMW-E3000 User manual Network Card 2
6 Sony AC-SQ950D User manual Network Card 0
7 Sony BBV RX100 User manual Network Card 3
8 Sony CLIE A-AVZ-100-11 User manual Network Card 1
9 Sony BTA-NW1 User manual Network Card 11
10 Sony AC-NWUM50 User manual Network Card 1
11 Sony AR-B1474 User manual Network Card 2
12 Sony BKM-FW32 User manual Network Card 1
13 Sony 4000CL-MAV-PBIO User manual Network Card 1
14 Sony FA-ST1AM User manual Network Card 0
15 Sony MVC-FDR3/FDR3E User manual Network Card 1