Burnham K50 user manual

User manual for the device Burnham K50

Device: Burnham K50
Category: Boiler
Manufacturer: Burnham
Size: 4.36 MB
Added : 11/3/2014
Number of pages: 116
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Burnham K50. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Burnham K50.

For your convenience

If looking through the Burnham K50 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Burnham K50 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Burnham K50 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Burnham K50 User manual - Online PDF
Advertisement
« Page 1 of 116 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Burnham K50 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Burnham K50. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION, OPERATING AND
SERVICE INSTRUCTIONS FOR
SERIES 5B
GAS-FIRED BOILER
For service or repairs to boiler, call your heating contractor. When seeking information on boiler,
provide Boiler Model Number and Serial Number as shown on Rating Label.
Boiler Model Number Boiler Serial Number Installation Date
K50_ _ _ _ _ _ _ _ _ 6_ _ _ _ _ _ _
Heating Contractor Phone Number
Address
Commercial Boilers
www.burnhamcommercialcastiron.com
84  302R  4-3/  0  PRice - $5.00


Summary of the content on the page No. 2

SecTiON i – eQUiPMeNT cHecK LiST U.S.A. EQUIPMENT CHECK LIST (For Canadian Equipment Check List, Turn to Pages 4 and 5) This Equipment Check List has been provided so that the Installer can determine if all parts have been provided for the boiler ordered. It covers standard equipment for both steam and water boilers without Tankless Heaters. Heaters or optional equipment ordered will be in addition to, or in lieu of, equipment shown below. By opening cartons in numerical sequence, boi

Summary of the content on the page No. 3

U.S.A. EQUIPMENT CHECK LIST BOILER SIZE 5006B 5007B 5008B 5009B 5010B 5011B 5012B 5013B 5014B 5015B 5016B 5017B 5018B 5019B 5020B 5021B 5022B 5024B 5026B CARTONS, PACKAGES OR BUNDLES 7 S Steam Trim Carton (Steam Boilers Only - Includes PA404 Pressure Limit Control) 4 Sizes - One Per Boiler 1 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 2 --- --- --- 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- 3 --- --- --- --- --- --- 1 1 1 1 1 1 1 1 1 --- -

Summary of the content on the page No. 4

cANADiAN eQUiPMeNT cHecK LiST This Equipment Check List has been provided so that the Installer can determine if all parts have been provided for the boiler ordered. It covers standard equipment for both steam and water boilers without Tankless Heaters. Heaters or optional equipment ordered will be in addition to, or in lieu of, equipment shown below. By opening cartons in numerical sequence, boiler assembly is simplified. If there is an exception, it will be pointed out in the boiler as

Summary of the content on the page No. 5

CANADIAN EQUIPMENT CHECK LIST BOILER SIZE 5006B 5007B 5008B 5009B 5010B 5011B 5012B 5013B 5014B 5015B 5016B 5017B 5018B 5019B 5020B 5021B 5022B 5024B 5026B CARTONS, PACKAGES OR BUNDLES 7 S Steam Trim Carton (Steam Boilers Only - Includes PA404 Pressure Limit Control) 4 Sizes - One Per Boiler 1 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 2 --- --- --- 1 1 1 --- --- --- --- --- --- --- --- --- --- --- --- --- 3 --- --- --- --- --- --- 1 1 1 1 1 1 1 1 1 ---

Summary of the content on the page No. 6

6 Top Supply NOTE Jacket Supply Approx. Drafthood Height, Size and Location and Rear Return Gas Conn. 1. 5006B THRU 5014B BOILERS REQUIRE Boiler Overall Conn. Return Conn. No. & Dia. of Shipping Location Size Nat. & Size Length Qty & Qty. & Size Flue Outlets Weight SINGLE GAS TRAIN LOCATION ON Propane ‘B’ ‘C’ ‘D’ ‘E’ ‘A’ Size (LB.) LEFT END OF BOILER (STANDARD) ‘F’ ‘G’ ‘H’ ‘J’ ‘K’ ‘M’ ‘N’ Dia. Dia. Dia. Dia. GAS TRAIN MAY BE RELOCATED 5006B 34 9 --- --- --- --- --- --- 17 19-3/4 --- --

Summary of the content on the page No. 7

SecTiON ii – GeNeRAL iNFORMATiON 1. BOILER INSTALLATION must conform to the requirements of the authority having jurisdiction, or in WARNiNG the absence of such requirements, to: Adequate combustion and ventilation air must USA – “National Fuel Gas Code, ANSI Z223.1”. be provided to assure proper combustion. When required by the authority having jurisdiction, a. Determine volume of space (boiler room). Rooms the installation must conform to American Society of communicating directl

Summary of the content on the page No. 8

equipment in space. Duct cross-sectional area 4. LOUVERS AND GRILLES of Ventilation Ducts shall be same as opening free area. All outside openings should be screened and louvered. 3. Horizontal ducts. Minimum free area of 1 Screens used should not be smaller than ¼ inch mesh. square inch per 2,000 Btu per hour input of all Louvers will prevent the entrance of rain and snow. equipment in space. Duct cross-sectional area a. Free area requirements need to consider the blocking sha

Summary of the content on the page No. 9

FIG. 3 DUAL MANIFOLD BASES - 5015B THRU 5026B SECTION BOILERS a. Carefully join a Center Section with nipples in adjoining section and bump lightly to secure. b. Run nut approximately 8” on two (2) ¾” draw-up rods of equal length. (Note – more than one set of draw-up rods are furnished on 8 section and larger boilers). Place draw-up channel and one flat washer against nut. c. Insert short end of draw-up rod through front & rear nipple ports on both sections, see Fig. 5. d. Plac

Summary of the content on the page No. 10

0 FIG. 6 ARRANGEMENT OF SECTIONS AND CANOPY(S)

Summary of the content on the page No. 11

e. DRAW UP CENTER SECTION SLOWLY AND it easier to join and draw-up. MOVE WOOD EVENLY, tightening each DRAW-UP ROD a little WEDGES FORWARD EACH time a Section has at a time so that sections are equally spaced. KEEP been drawn up. NIPPLES ALIGNED WITH NIPPLE PORTS. If 7. ASSEMBLE REMAINING END SECTION WITH necessary, tap Nipples lightly with a blunt tool or DRAW-UP RODS in a manner similar to that for rod to keep Nipples from cocking while Sections are assembling Center Sections. Remo

Summary of the content on the page No. 12

FIG. 8 FIG. 9 INSTALLATION OF BUILT-IN HEATER TESTING BOILER ASSEMBLY FOR LEAKS Open Tankless Heater Carton(s) If Supplied. 11. EXAMINE BOILER CAREFULLY, INSIDE AND Open Heater Opening Cover Plate Carton(s). OUTSIDE, to insure against leaks from cocked nipples 9. INSTALL BUILT-IN WATER HEATER(S) OR or through concealed breakage caused in shipping and HEATER OPENING COVER PLATE(S), See Fig. handling. This precaution is for your protection and 8. Heater may be installed in either End Se

Summary of the content on the page No. 13

FIG. 10 FIG. 11 SEALING OF BASE, INSTALLATION OF ATTACHMENT OF FLUE COVERS FLUE COVERS AND CANOPIES a. With Steam Heating System, refer to Fig. 12, 13A, automatic means to prevent gravity circulation of 13B. the Boiler Water during the cooling cycle. c. With COMBINATION HEATING AND COOLING NOTice (REFRIGERATION) SYSTEMS having the same Distributing Units, Piping and Circulator, See Fig. Before using copper for steam piping, consider 15. For additional reference, consult ASHRAE the fol

Summary of the content on the page No. 14

4 FIG. 12 RECOMMENDED STEAM BOILER PIPING, GRAVITY RETURN I OR 2 SUPPLY CONNECTIONS - 5006B THRU 5014B

Summary of the content on the page No. 15

5 FIG. 13A RECOMMENDED STEAM BOILER PIPING, GRAVITY RETURN 3 SUPPLY CONNECTIONS - 5015B THRU 5020B

Summary of the content on the page No. 16

6 FIG. 13B RECOMMENDED STEAM BOILER PIPING, GRAVITY RETURN 4 OR 5 SUPPLY CONNECTIONS - 5021B THRU 5026B

Summary of the content on the page No. 17

7 FIG. 13C TYPICAL STEAM PIPING ARRANGEMENT FOR BOILERS WITH PUMPED CONDENSATE RETURN AND BOILER FEED UNIT

Summary of the content on the page No. 18

8 FIG. 14A FIG. 14B RECOMMENDED WATER BOILER PIPING RECOMMENDED WATER BOILER PIPING I SUPPLY CONNECTION & I RETURN CONNECTION 3 SUPPLY CONNECTIONS & 2 RETURN CONNECTIONS SIZES 5006B THRU 5019B SIZES 5020B THRU 5026B

Summary of the content on the page No. 19

2. Attach Lower Left and Lower Right Jacket End Panels to their respective brackets using #10-32 x ½” self-tapping screws, see Fig. 17. 3. See Fig. 7 “Purpose of Tappings and Their Location” and remove necessary knockouts from Upper Left and from Upper Right Jacket End Panels. 4. Place Upper Right End Panel on top of Lower Right End Panel with lip on bottom of Upper Panel positioned behind Lower Panel. Secure to section using #10-32 x ½” self-tapping screws. Attach Upper Left E

Summary of the content on the page No. 20

FIG. 17 INSTALLATION OF JACKET END PANELS FIG. 18 VESTIBULE ATTACHMENT DIAGRAM 20


Alternative user manuals
# User manual Category Download
1 Burnham ALP105 User manual Boiler 15
2 Burnham 81433101R16-1/10 User manual Boiler 1
3 Burnham 8H User manual Boiler 14
4 Burnham ALP080 User manual Boiler 2
5 Burnham ALP150 User manual Boiler 3
6 Burnham ALPINETM 101603-01R2-12/09 User manual Boiler 2
7 Burnham ALP399 User manual Boiler 0
8 Burnham S User manual Boiler 18
9 Burnham Carefree DOE User manual Boiler 4
10 Burnham ALP210 User manual Boiler 57
11 Burnham CHG225 User manual Boiler 1
12 Burnham ALP285 User manual Boiler 3
13 Burnham CHG150 User manual Boiler 3
14 Burnham Condensing Stainless Steel User manual Boiler 4
15 Burnham Gas-Fired User manual Boiler 1
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6