Burnham V8 Series user manual

User manual for the device Burnham V8 Series

Device: Burnham V8 Series
Category: Boiler
Manufacturer: Burnham
Size: 5.82 MB
Added : 11/3/2014
Number of pages: 100
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Burnham V8 Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Burnham V8 Series.

For your convenience

If looking through the Burnham V8 Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Burnham V8 Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Burnham V8 Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Burnham V8 Series User manual - Online PDF
Advertisement
« Page 1 of 100 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Burnham V8 Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Burnham V8 Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

8
INSTALLATION, OPERATING AND
SERVICE INSTRUCTIONS FOR
V8 SERIES
OIL - FIRED BOILER
As an
ENERGY
®
STAR Partner,
Burnham Hydronics
has determined that the
V83S, V83WM, V84S,
V84WM, V85S, V85WM,
V86S, V86WM and V87
®
meet the ENERGY STAR
guidelines for Energy
efficiency established by the
United States Environmental
Protection Agency (EPA).
For service or repairs to boiler, call your heat

Summary of the content on the page No. 2

IMPORTANT INFORMATION - READ CAREFULLY All boilers must be installed in accordance with National, State and Local Plumbing, Heating All boilers must be installed in accordance with National, State and Local Plumbing, Heating a and Electrical Codes and the r nd Electrical Codes and the re egulations of the serving utilities. gulations of the serving utilities. T These Codes and Regulations hese Codes and Regulations may differ may differ fr fro om this instruction manual. m this instructio

Summary of the content on the page No. 3

DANGER DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Failure to follow all instructions in the proper order can cause personal injury or death. Read and understand all instructions, including all those contained in component manufacturers manuals which are provided with the appliance before in

Summary of the content on the page No. 4

WARNING This boiler contains very hot water under high pressure. Do not unscrew any pipe fittings nor attempt to disconnect any components of this boiler without positively assuring the water is cool and has no pressure. Always wear protective clothing and equipment when installing, starting up or servicing this boiler to prevent scald injuries. Do not rely on the pressure and temperature gauges to determine the temperature and pressure of the boiler. This boiler contains components which become

Summary of the content on the page No. 5

TABLE 1A: DIMENSIONAL DATA (SEE FIGURES 1A THRU 1D) Heat T Heat Transfer ransfer Dimensions Dimensions W Wa ater Content - Gallons ter Content - Gallons S Surface Area urface Area A Approximate pproximate S See Figures 1A ee Figures 1A - 1D - 1D B Boiler oiler - Sq. Ft. - Sq. Ft. S Shipping W hipping Weight eight Model No. Model No. (LB.) (LB.) S Steam team W Wa ater ter S Steam Boiler team Boiler " "A" A" "B" "B" "C" "C" Boiler Boiler Boiler Boiler V82 V82 1 12-1/8" 2-1/8" 6-5/8" 6-5/8"

Summary of the content on the page No. 6

6 Figure 1A: V82 thru V89 Water Boiler without Tankless Heater

Summary of the content on the page No. 7

7 Figure 1B: V83 thru V89 Water Boiler with Front Tankless Heater

Summary of the content on the page No. 8

8 Figure 1C: V83 thru V89 Water Boiler with Rear Tankless Heater

Summary of the content on the page No. 9

9 Figure 1D: V83 thru V89 Steam Boiler with or without Tankless Heater

Summary of the content on the page No. 10

SECTION I: PRE-INSTALLATION A. INSPECT SHIPMENT carefully for any signs of not level, or if water may be encountered on fl oor damage. around boiler. 1. All equipment is carefully manufactured, inspected 4. PROVIDE SERVICE CLEARANCE of at least and packed. Our responsibility ceases upon delivery 24” clearance from front jacket panel for servicing of crated boiler to the carrier in good condition. and removal of front tankless heater (increase to 30" for #A54 heater). If boiler is equip

Summary of the content on the page No. 11

b. Outdoor air may be provided with the use of two C. PROVIDE COMBUSTION AND VENTILATION permanent openings which communicate directly AIR. Local and National Codes may apply and should or by duct with the outdoors or spaces (crawl or be referenced. attic) freely communicating with the outdoors. Locate one opening within 12 inches of top WARNING of space. Locate remaining opening within 12 Adequate combustion and ventilation inches of bottom of space. Minimum dimension air must be

Summary of the content on the page No. 12

SECTION II: KNOCKDOWN BOILER ASSEMBLY G. INSTALL AND SECURE CANOPY with gasket A. REMOVAL OF BARE BOILER FROM SKID and hardware provided to ensure gas tight seal — see 1. Boiler is secured to skid with 4 bolts, 2 in front and Figure 4. 2 in rear of shipping skid, see Figure 3. Remove all bolts. Figure 3: Knockdown Boiler Removal from Skid 2. Tilt boiler to right and to rear. Using right rear leg as pivot, rotate boiler 90° in a clockwise direction, and lower left side of boi

Summary of the content on the page No. 13

Figure 5: Boiler Tapping Locations and Usage (Knockdown Boilers Only) PURPOSE OF TAPPINGS Sr team Boiler Water Boile Tapping Size Location NPT Nr on-Heaterwr /HeateNr on-HeateFr ront Heate Rear Heate Pressure Limit (Probe LWCO) L8148A L8124C A" ¾ Flush Plug Plugged (Float LWCO) Operating Control Operating Control B" ¼ Pressure Gauge Temperature/Pressure Gauge Probe LWCO Std. N/A C" ¾ Plugged (Float LWCO) C" -C ¾Fg lush PlugFA lush Plu N/ Water Gauge Glass (Probe LWCO) D" ½ N/A Water Gauge Glass,

Summary of the content on the page No. 14

Figure 6: Knockdown Boiler Jacket Assembly H. INSTALL TRIM. The following steam or water trim 2. Install jacket rear panel support bracket. (See Figure will be concealed or inaccessible after boiler jacket is 6, Item 2A). Align bracket with two (2) 5/16" - 18 installed, see Figure 5 for boiler tapping locations and tapped holes in rear section and secure with two (2) usage. 5/16" - 18 x 1/2" long cap screws. 1. STEAM BOILER — Top tappings: 3. Install jacket rear panel. (See Figure 6

Summary of the content on the page No. 15

Figure 7: Oil Burner Installation (Beckett Burner Shown) 6. Install jacket top panel. (See Figure 6, Item 2F). 2. Locate burner swing door and hinge assembly Place jacket top panel on boiler and secure to front, removed in Paragraph I, No. 1. Check the burner rear and left side panels with #8 x ½” long sheet swing door insulation and rope gasket for damage metal screws. and adhesion. If damaged, replace insulation or gasket. If insulation or gasket is loose, reattach to 7. Install

Summary of the content on the page No. 16

e. Remove nozzle line electrode assembly. NOTICE f. Remove Beckett MD(V1) or MB(L1) Head. g. Remove plug from nozzle adapter and install When securing burner swing door make the proper nozzle. Refer to Table 6 for proper sure door is drawn-in equally on both sides. nozzle. The nozzle must be securely installed Step 3. Use a hand wrench to tighten door hardware to assure leak free joints between the nozzle and and always start with the right side fl ange adapter. When installing the nozz

Summary of the content on the page No. 17

Disconnect the fl ared fi tting to the oil line and remove the aluminum thumb-nut from the nozzle line. Remove the combustion head assembly from the air tube. Rotating the assembly upside down will ease removal. Inspect the nozzle for size and type, refer to Table 6 of this manual. ii. To change a nozzle, loosen the clamp screw on the retention ring assembly and slide the retention ring off the adaptor. Install and tighten the proper nozzle in the adaptor. See Table 6 of this m

Summary of the content on the page No. 18

L. INSTALL CARLIN ELITE EZ OIL BURNER. iv. Replace the retention ring assembly, slipping (See Figure 7). one of the riveted arms through the 1/8-inch gap between the electrode tips. This arm Follow instructions in Paragraph J, Steps 1 through 6. should be straight up. Also, be sure that 7. Inspect oil nozzle, electrodes and head setting/ the retention ring clamp is tight against the change fi ring rate. shoulder on the adaptor. Then tighten the clamping screw. DANGER v. Check the ele

Summary of the content on the page No. 19

c. Initial Air Band Setting CAUTION i. The nozzle size in GPH INPUT is printed directly on the air band. Loosen the locking Steam boilers must only be operated at the screw, move the air band until the pointer lower input. Increasing the firing rate on the air shutter and housing lines up with above this input will result in accelerated the appropriate GPH INPUT. Tighten the boiler corrosion and will void the warranty locking screws. provided with the boiler. ii. The Elite burners use cal

Summary of the content on the page No. 20

Figure 7D: Turbulator Setting iii. Retighten the retaining nut (1). MODEL F3 NOTE: Zero and three are scale Figure 7C: Nozzle Replacement indicators only. From left to right the fi rst line is i. Remove the nozzle adapter (2) from the 3 and the last line 0. drawer assembly by loosening the screw (1). MODEL F5: Same as above, except, scale ii. Remove existing nozzle from nozzle indicators are 0 and 4. adapter. MODEL F10: Same as above, except, scale iii. Insert the proper nozzle int


Alternative user manuals
# User manual Category Download
1 Burnham ALP105 User manual Boiler 15
2 Burnham 81433101R16-1/10 User manual Boiler 1
3 Burnham 8H User manual Boiler 14
4 Burnham ALP080 User manual Boiler 2
5 Burnham ALP150 User manual Boiler 3
6 Burnham ALPINETM 101603-01R2-12/09 User manual Boiler 2
7 Burnham ALP399 User manual Boiler 0
8 Burnham S User manual Boiler 18
9 Burnham Carefree DOE User manual Boiler 4
10 Burnham ALP210 User manual Boiler 57
11 Burnham CHG225 User manual Boiler 1
12 Burnham ALP285 User manual Boiler 3
13 Burnham CHG150 User manual Boiler 3
14 Burnham Condensing Stainless Steel User manual Boiler 4
15 Burnham Gas-Fired User manual Boiler 1
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6