Sierra INNOVA-MASS 240-VTP user manual

User manual for the device Sierra INNOVA-MASS 240-VTP

Device: Sierra INNOVA-MASS 240-VTP
Category: Network Router
Manufacturer: Sierra
Size: 1.59 MB
Added : 9/19/2013
Number of pages: 92
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sierra INNOVA-MASS 240-VTP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sierra INNOVA-MASS 240-VTP.

For your convenience

If looking through the Sierra INNOVA-MASS 240-VTP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sierra INNOVA-MASS 240-VTP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sierra INNOVA-MASS 240-VTP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sierra INNOVA-MASS 240-VTP User manual - Online PDF
Advertisement
« Page 1 of 92 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sierra INNOVA-MASS 240-VTP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sierra INNOVA-MASS 240-VTP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Series 24-HP Instruction Manual Table of Contents




Sierra Series 240 and 241
Innova-Mass™ Multi-Parameter
Vortex Mass Flow Meters

Models 240-VT, 240-VTP, 241-VT, 241-VTP

Instruction Manual

Part Number: IM-24-HP, Rev. C 11/07




CORPORATE HEADQUARTERS
5 Harris Court, Building L, Monterey, CA 93940
Phone (831) 373-0200 (800) 866-0200 Fax (831) 373-4402
www.sierrainstruments.com


EUROPE HEADQUARTERS
Bijlmansweid 2 1934RE Egmond ann den Hoef The Netherlands
Phone

Summary of the content on the page No. 2

Table of Contents Series 24-HP Instruction Manual Customer Notice Unless you have specifically ordered Sierra’s optional O cleaning, this flow meter 2 may not be fit for oxygen service. Sierra Instruments, Inc., is not liable for any damage or personal injury, whatsoever, resulting from the use of Sierra Instru- ments standard mass flow meters for oxygen gas. You are responsible for clean- ing the mass flow meter to the degree required for your oxygen flow application.

Summary of the content on the page No. 3

Series 24-HP Instruction Manual Table of Contents Table of Contents Chapter 1 Introduction Innova-Mass™ Vortex Mass Flow Meters.......................................... 1-1 Using this Manual ......................................................................... 1-1 Note and Safety Information......................................................... 1-2 Receipt of System Components .................................................... 1-2 Technical Assistance.......................

Summary of the content on the page No. 4

Table of Contents Series 24-HP Instruction Manual Energy Menu.......................................................................3-10 Fluid Menu.................................................................................. 3-11 Units Menu.................................................................................. 3-12 Time and Date Menu................................................................... 3-13 Diagnostics Menu................................................

Summary of the content on the page No. 5

Series 24-HP Instruction Manual Table of Contents Figures 1-1. In-Line Vortex Multi-Parameter Mass Flow Meter ............... 1-3 1-2. Measurement Principle of Vortex Flow Meters..................... 1-4 1-3. Reynolds Number Range of the Innova-Mass........................ 1-6 2-1. Recommended Pipe Length Required for Installation ........... 2-2 2-2. Flange Bolt Torquing Sequence ............................................. 2-3 2-3. Wafer-Style Flow Meter Installation................

Summary of the content on the page No. 6

Table of Contents Series 24-HP Instruction Manual Warnings and Cautions Warning! Agency approval for hazardous location installations varies between flow meter models. Consult the flow meter nameplate for specific flow meter approvals before any hazardous location installation. Hot tapping must be performed by a trained professional. U.S. regulations often require a hot tap permit. The manufacturer of the hot tap equipment and/or the contractor perform- ing the hot tap is respon

Summary of the content on the page No. 7

Series 24-HP Instruction Manual Chapter 1 Introduction Chapter 1 Introduction ™ Innova-Mass Multi-Parameter Vortex Mass Flow Meters The Sierra Instruments’ Series 240 In-Line and the Series 241 Insertion Innova-Mass™ Vortex Flow Meters provide a reliable solution for proc- ess flow measurement. From a single entry point in the pipeline, Innova- Mass meters offer precise measurements of five parameters including mass flow, volumetric flow, temperature, pressure and fluid density. The uniq

Summary of the content on the page No. 8

Chapter 1 Introduction Series 24-HP Instruction Manual Note and Safety Information We use note, caution and warning statements throughout this book to draw your attention to important information. Caution! Note Warning! This statement appears with This statement appears with This statement appears with a information that is important to information that is important short message to alert you to protect people and equipment for protecting your equipment an important detail. from

Summary of the content on the page No. 9

Series 24-HP Instruction Manual Chapter 1 Introduction How the Innova-Mass Vortex Mass Flow Meter Operates Figure 1-1. In-Line Vortex Multi-Parameter Mass Flow Meter Sierra Series 240 and 241 Innova-Mass™ Multi-Parameter Vortex Mass Flow Meters use a unique sensor head to monitor mass flow rate by di- rectly measuring three variables–fluid velocity, temperature and pres- sure. The built-in flow computer calculates the mass flow rate and volu- metric flow rate based on these three dire

Summary of the content on the page No. 10

Chapter 1 Introduction Series 24-HP Instruction Manual Vortex Shedding Frequency Von Karman vortices form downstream of a shedder bar into two dis- tinct wakes. The vortices of one wake rotate clockwise while those of the other wake rotate counterclockwise. Vortices generate one at a time, alternating from the left side to the right side of the shedder bar. Vortices interact with their surrounding space by over-powering every other nearby swirl on the verge of development. Close to the

Summary of the content on the page No. 11

Series 24-HP Instruction Manual Chapter 1 Introduction Flow Velocity Range To ensure trouble-free operation, vortex flow meters must be correctly sized so that the flow velocity range through the meter lies within the measurable velocity range (with acceptable pressure drop) and the linear range. The measurable range is defined by the minimum and maximum velocity using the following table. Gas Liquid 25 ft/s 3 ρ Vmin 1 ft/s English ρ (lb/ft ) Vmax 300 ft/s 30 ft/s 37 m/

Summary of the content on the page No. 12

Chapter 1 Introduction Series 24-HP Instruction Manual As shown in Figure 1-3, Innova-Mass™ meters exhibit a constant Strou- hal number across a large range of Reynolds numbers, indicating a con- sistent linear output over a wide range of flows and fluid types. Below this linear range, the intelligent electronics in Innova-Mass automatically corrects for the variation in the Strouhal number with the Reynolds num- ber. The meter’s smart electronics corrects for this non-linearity via its sim

Summary of the content on the page No. 13

Series 24-HP Instruction Manual Chapter 1 Introduction Pressure Measurement Innova-Mass Flow Meters incorporate a solid-state pressure transducer isolated by a 316 stainless steel diaphragm. The transducer itself is mi- cro-machined silicon, fabricated using integrated circuit processing tech- nology. A nine-point pressure/temperature calibration is performed on every sensor. Digital compensation allows these transducers to operate within a 0.3% of full scale accuracy band within the entir

Summary of the content on the page No. 14

Chapter 1 Introduction Series 24-HP Instruction Manual Flow Meter Electronics Innova-Mass Flow Meter electronics are available mounted directly to the flow body, or remotely mounted. The electronics housing may be used indoors or outdoors, including wet environments. Power require- ments are 100 milliamps at 12-36 VDC. An optional AC powered unit is available. Three analog output signals are available for your choice of three of the five process variables: mass flow rate, volumetric flow

Summary of the content on the page No. 15

Series 24-HP Instruction Manual Chapter 2 Installation Chapter 2 Installation Installation Overview Sierra’s Innova-Mass Vortex Flow Meter installations are simple and straightforward. Both the Series 240 In-Line and Series 241 Insertion type flow meter installations are covered in this chapter. After reviewing the installation requirements given below, see page 2-3 for Series 240 instal- lation instructions. See page 2-6 for Series 241 installation instructions. Wiring instructions beg

Summary of the content on the page No. 16

Chapter 2 Installation Series 24-HP Instruction Manual Unobstructed Flow Requirements Select an installation site that will minimize possible distortion in the flow profile. Valves, elbows, control valves and other piping components may cause flow disturbances. Check your specific piping condition against the examples shown below. In order to achieve accurate and re- peatable performance install the flow meter using the recommended number of straight run pipe diameters upstream and downst

Summary of the content on the page No. 17

Series 24-HP Instruction Manual Chapter 2 Installation Series 240 In-Line Flow Meter Installation Install the Series 240 In-Line Flow Meter between two conventional pipe flanges as shown in Figures 2-3 and 2-4. Table 2-1 provides the recom- mended minimum stud bolt lengths for wafer-style meter body size and different flange ratings. The meter inside diameter is equal to the same size nominal pipe ID in schedule 80. For example, a 2” meter has an ID of 1.939” (2” schedule 80). Do not

Summary of the content on the page No. 18

Chapter 2 Installation Series 24-HP Instruction Manual Wafer-Style Flow Meter Installation Install the wafer-style meter between two conventional pipe flanges of the same nominal size as the flow meter. If the process fluid is a liquid, make sure the meter is located where the pipe is always full. This may require locating the meter at a low point in the piping system. Note: Vortex flow meters are not suitable for two-phase flows (i.e., liquid and gas mixtures). For horizontal pipelines

Summary of the content on the page No. 19

Series 24-HP Instruction Manual Chapter 2 Installation Flange-Style Flow Meter Installation Install the flange-style meter between two conventional pipe flanges of the same nominal size as the flow meter. If the process fluid is a liquid, make sure the meter is located where the pipe is always full. This may re- quire locating the meter at a low point in the piping system. Note: Vortex flow meters are not suitable for two-phase flows (i.e., liquid and gas mix- tures). For horizontal pipeli

Summary of the content on the page No. 20

Chapter 2 Installation Series 24-HP Instruction Manual Series 241 Insertion Flow Meter Installation Prepare the pipeline for installation using either a cold tap or hot tap method described on the following pages. Refer to a standard code for all pipe tapping operations. The following tapping instructions are general in nature and intended for guideline purposes only. Before installing the me- ter, review the mounting position and isolation value requirements given below. Mounting Posit


Alternative user manuals
# User manual Category Download
1 Sierra INNOVA-MASS 240-VT User manual Network Router 0
2 Sierra INNOVA-MASS 241-VT User manual Network Router 2
3 Sierra INNOVA-MASS 241-VTP User manual Network Router 0
4 Sony BKS-R3202/R3210/R3220 User manual Network Router 77
5 Sony DVS-V3232B/V3232M User manual Network Router 3
6 Sony BVS-V3232 User manual Network Router 8
7 Sony DMX-WL1 User manual Network Router 6
8 Sony BVS-A3232 User manual Network Router 6
9 Sony BKS-R1601 User manual Network Router 3
10 Sony CI-100 User manual Network Router 0
11 Sony ECM-3711 User manual Network Router 0
12 Sony AIRLINK HELIX 2140847 User manual Network Router 2
13 Sony DVS-V1616 User manual Network Router 0
14 Sony HKJ-101 User manual Network Router 0
15 Sony 3-855-935-02(1) User manual Network Router 0