Lochinvar 81 - 286 user manual

User manual for the device Lochinvar 81 - 286

Device: Lochinvar 81 - 286
Category: Boiler
Manufacturer: Lochinvar
Size: 0.91 MB
Added : 9/26/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lochinvar 81 - 286. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lochinvar 81 - 286.

For your convenience

If looking through the Lochinvar 81 - 286 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lochinvar 81 - 286 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lochinvar 81 - 286 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lochinvar 81 - 286 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lochinvar 81 - 286 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lochinvar 81 - 286. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

KBII-USER Rev D
User’s Information Manual
Models: 81 - 286
 WARNING
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or
loss of life.
This appliance MUST NOT be installed in any location where
gasoline or flammable vapors are likely to be present.
WHAT TO DO IF YOU SMELL GAS
� Do not try to light any appliance.
� Do not touch any electric switch; do not use any phone in your
building.
� Immediately call your

Summary of the content on the page No. 2

Contents HAZARD DEFINITIONS .................................................... 2 3. OPERATING INSTRUCTIONS ..................................... 9 PLEASE READ BEFORE PROCEEDING ........................ 3 4. SMART SYSTEM CONTROL MODULE 1. PREVENT COMBUSTION AIR CONTAMINATION..... 4 SMART SYSTEM Control Module ................................... 10 2. MAINTENANCE SCHEDULE ....................................... 5 Access Modes ............................................................ 1

Summary of the content on the page No. 3

User’s Information Manual Please read before proceeding The Knight Boiler Installation and Boiler service and maintenance – NOTICE Operation Manual along with the Knight � To avoid electric shock, disconnect electrical supply Boiler Service Manual are for use only before performing maintenance. by a qualified heating installer/service � To avoid severe burns, allow boiler to cool before technician. Refer only to this User’s performing maintenance. Information Manual for you

Summary of the content on the page No. 4

User’s Information Manual 1 Prevent combustion air contamination If the boiler combustion air inlet is located  WARNING Table 1 Corrosive Contaminants and Sources in any area likely to cause contamination, or if products which would contaminate Products to avoid: the air cannot be removed, you must have the combustion air and vent re-piped Spray cans containing chloro/fluorocarbons and terminated to another location. Contaminated combustion air will damage Permanent wave solu

Summary of the content on the page No. 5

User’s Information Manual 2 Maintenance schedule Owner maintenance Service technician (see pages 6 - 8 for detailed instructions) (see the Knight Boiler Service Manual) • Check boiler area General: • Reported problems • Check pressure/temperature gauge • Inspect interior; clean and vacuum if Daily necessary • Clean condensate trap and fill with fresh water • Check for leaks (water, gas, flue, condensate) • Check vent piping • Verify flue and air lines in good co

Summary of the content on the page No. 6

User’s Information Manual 2 Maintenance schedule Read the list of potential materials listed in Table 1 on Maintenance procedures page 4 of this manual. If any of these products are in the room from which the boiler takes its combustion air, they Boiler must be serviced and maintained must be removed immediately or the boiler combustion air (and vent termination) must be relocated to another The boiler must be inspected and started  WARNING area. annually at the beginni

Summary of the content on the page No. 7

User’s Information Manual 2 Maintenance schedule (continued) 3. Fill with fresh water until the water begins to pour out of Use materials approved by the authority NOTICE the drain. having jurisdiction. In the absence of other authority, PVC and CPVC pipe 4. Replace the cap. Press the cap onto the trap until the cap must comply with ASTM D1785 or D2845. makes contact with the drain. Cement and primer must comply with 5. Replace the retaining screw. ASME D2564 or F493. F

Summary of the content on the page No. 8

User’s Information Manual 2 Maintenance schedule Check air vents Have leaks fixed at once by a qualified  WARNING service technician. Failure to comply could 1. Reference FIG. 3 below. result in severe personal injury, death, or substantial property damage. 2. Visually inspect vent to make sure that no leaks are 3. Replace the front access door. present. 3. If there is leaking, tighten the pin valve. Operate relief valve 4. If the leak continues, replace the air vent. 1. Bef

Summary of the content on the page No. 9

User’s Information Manual 3 Operating instructions o C 9

Summary of the content on the page No. 10

User’s Information Manual 4 SMART SYSTEM control module Knight boiler control module Use the control panel (FIG. 4) to set temperatures, operating conditions, and monitor boiler operation. Figure 4 Control Panel NAVIGATION DIAL The information on the bottom of the display shows the functions of the two SELECT keys (on either corner), and the NAVIGATION dial (in the center): MENU = Left SELECT Key SETPOINTS = NAVIGATION Dial - Pressing Down SHDN = Right SELECT Key

Summary of the content on the page No. 11

User’s Information Manual 4 SMART SYSTEM control module (continued) Night Setback Override Space heating (SH1, SH2, SH3) and tank set points Any Night Setback On trigger currently active or scheduled Mixing valves are required for the within the next seven (7) days can be skipped. To skip a CAUTION protection of any low temperature loops. trigger, rotate the NAVIGATION dial until the arrow (>) is next to the trigger you wish to skip. Press the NAVIGATION dial once. “SK” wil

Summary of the content on the page No. 12

User’s Information Manual 4 SMART SYSTEM control module Figure 5 Status Display Screen B A (CALL FOR (BOILER HEAT) STATUS) C (OPERATIONAL INFORMATION) F D (RIGHT SELECT KEY) (LEFT SELECT KEY) E (NAVIGATION DIAL) Status Display Screens Section Display Description The unit has not received a call for heat from a remote thermostat nor STANDBY has it received a call for heat from a DHW thermostat. START The unit has begun a burn cycle and is checking all safety circuits. PREPURGE The

Summary of the content on the page No. 13

User’s Information Manual 4 SMART SYSTEM control module (continued) Status Display Screens (cont’d) Section Display Description SYSTEM: The temperature read by the system supply sensor (if connected). TANK: The temperature read by the tank sensor (if connected). OUTDOOR: The temperature read by the outdoor sensor (if connected). INLET TEMP: The temperature read at the inlet to the heat exchanger. OUTLET TEMP: The temperature read at the outlet of the heat exchanger. The temperature di

Summary of the content on the page No. 14

User’s Information Manual 4 SMART SYSTEM control module Status Display Screens (cont’d) Section Display Description Press and hold the LEFT SELECT key for 5 seconds to enter the Menu MENU Screen. EXIT Press the LEFT SELECT key to exit the current screen or setting. Press the LEFT SELECT key to confirm that the boiler needs to YES D shutdown. (LEFT SELECT Press the LEFT SELECT key to enter the screen that allows you to LIMITS key function) adjust the limit settings. Press the LEFT

Summary of the content on the page No. 15

User’s Information Manual Notes 15

Summary of the content on the page No. 16

Revision Notes: Revision A (ECO C05747) initial release. Reflects the new model numbers for the Knight upgrade. Revision B (ECO C07072) reflects the change in design of manual air vent valve and the update of FIG. 3 on page 8. Revision C (ECO #C09197) updates made to the SMART SYSTEM control (ECR #R04523). Revision D (ECO #C10143) reflects updates made to the ignition timing information. KBII-USER Rev D 04/12


Alternative user manuals
# User manual Category Download
1 Lochinvar 000 - 260 User manual Boiler 4
2 Lochinvar 051-211 User manual Boiler 0
3 Lochinvar 1 User manual Boiler 0
4 Lochinvar 000 through 2 User manual Boiler 2
5 Lochinvar 000 BTU/HR User manual Boiler 5
6 Lochinvar 1.3 User manual Boiler 0
7 Lochinvar 0402-0752 User manual Boiler 1
8 Lochinvar 1.5 User manual Boiler 0
9 Lochinvar 2001 User manual Boiler 0
10 Lochinvar 2 User manual Boiler 0
11 Lochinvar 151 User manual Boiler 0
12 Lochinvar 1701 User manual Boiler 0
13 Lochinvar 151-286 User manual Boiler 0
14 Lochinvar 2.5 User manual Boiler 0
15 Lochinvar 45 User manual Boiler 0
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6