Monessen Hearth Double Door VFCS20DNV user manual

User manual for the device Monessen Hearth Double Door VFCS20DNV

Device: Monessen Hearth Double Door VFCS20DNV
Category: Oven
Manufacturer: Monessen Hearth
Size: 2.67 MB
Added : 6/19/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Monessen Hearth Double Door VFCS20DNV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Monessen Hearth Double Door VFCS20DNV.

For your convenience

If looking through the Monessen Hearth Double Door VFCS20DNV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Monessen Hearth Double Door VFCS20DNV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Monessen Hearth Double Door VFCS20DNV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Monessen Hearth Double Door VFCS20DNV User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Monessen Hearth Double Door VFCS20DNV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Monessen Hearth Double Door VFCS20DNV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED GAS
CAST IRON STOVE
INSTALLATION AND OPERATING
INSTRUCTIONS
SINGLE DOOR MODELS:
CSVF20SNV CSVF30SNV
CSVF20SPV CSVF30SPV
DOUBLE DOOR MODELS:
VFCS20DNV VFCS30DNV
VFCS20DPV VFCS30DPV
Natural Gas or
Propane/LPG
Milli-Volt Control
WARNINGS
WARNINGS
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
– Do not store or use gasoline or other flammable
This appliance may be installe

Summary of the content on the page No. 2

CONTENTS Important Safety Information .......................... 3 Rock Wool Installation.................................... 18 Flame Appearance .......................................... 19 Product Features .............................................. 5 Checking Pilot Flame .................................. 19 Dimensions ....................................................... 6 Checking the Burner Flame ........................  0 Getting Started .......................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. IMPORTANT Read these instructions carefully before installing or trying to operate this vent-free gas heater. • Any change to this heater or its controls can be dangerous. • Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning. • Do not allow fans to blow directly i

Summary of the content on the page No. 4

IMPORTANT SAFETY INFORMATION Continued from page 3 20. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 16. Keep room area clear and free from combustible materi- feet, input ratings should be reduced 4 percent for each als, gasoline and other flammable vapors and liquids. 1,000 feet above sea level. Refer to the National Fuel 17. Unvented gas heaters are a supplemental

Summary of the content on the page No. 5

PRODUCT FEATURES On/Off Switch Handle Optional Remote Receiver Piezo Hi/Lo Knob Off/Pilot/On Knob Fan Switch Door Figure 1 - Cast Iron Stove (Single Door) Break-Away Handle On/Off Switch Optional Remote Receiver Piezo Hi/Lo Knob Off/Pilot/On Knob Store Break-Away Optional Handle Here Figure 2 - Cast Iron Stove Fan Switch (Double Door) 58D6002  ON OFF ON OFF

Summary of the content on the page No. 6

DIMENSIONS A C B Figure 3 - Dimensions CSVF20S/VFCS20D CSVF30S/VFCS30D 1 3 A  1 /4"  6 /4" 1 B  3"  8 / " 1 3 C 16 / " 19 /4" 6 58D6002

Summary of the content on the page No. 7

MAk E SURE YOU HAVE RECEIVED ALL PARTS: Check your packing list to verify that all listed parts have be en receiv ed. Y ou should have the following: • Cast Iron Stove with Burner Assembly • Installation/Operating Instructions • Ceramic Fiber Logs • Touch-up Paint Millivolt controlled heater designed to be operated with optional devices for ON/OFF functions. • Hand-Held Remote with Manual Receiver • Wall Switch with 15' Wire Gloves are reco

Summary of the content on the page No. 8

PRODUCT SPECIFICATIONS NATURAL GAS 1 NOTE: An external regulator is required to reduce supply pressure to a maximum of 10 /2" w.c. on Natural Gas systems operating at higher pressure. MILLIVOLT PRESSURE Regulator Pressure Setting: 3.5" w .c. Pilot Regulator: 3.5" w .c. Gas Inlet Pressure: Max. 10 1/2" w . c. Min. 5" w .c. Gas Rate Model Number Type Max. BTU/Hr Min. BTU/Hr CSVF 0SNV/VFCS 0DNV (G-EBL-ES-EMB) Milli-Volt 10,000 6,000 CSVF30SNV/VFCS30DNV (G-E

Summary of the content on the page No. 9

GENERAL INSTALLATION INFORMATION Do not install the heater … • Where curtains, furniture, clothing, or other flammable objects are less than 42" from the front of the heater. • In high traffic areas. • In windy or drafty areas. CODES Adhere to all local codes or , in their absence, the latest edition of THE NA TIONAL FUEL GAS CODE ANSI Z223.1 or NFP A54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway New Y ork, NY 10018 or Nati

Summary of the content on the page No. 10

L L 2 1 GENERAL INSTALLATION INFORMATION Counter Cast Iron Stove Figure 4 - Example of a Large Room with 1/2 Wall Divider The following formula can be used to determine the maximum heater rating per the definition of unconfined space: BTU/Hr = (L1 + L ) Ft x (W) Ft x (H) Ft x 1000  0 Consider two connecting rooms with an open area between, with the following dimensions: 1 L1 = 1 / Ft., L = 1 Ft., W = 1 Ft., H = 8 Ft. 1 BTU/Hr = (1 / + 1 ) x (1 ) x (8) x 1000 =  800

Summary of the content on the page No. 11

CLEARANCES / HEIGHT REQUIREMENTS The dimensions shown in Figure 5 are minimum clearances to maintain in installing this heater. Left and right clearances are determined when facing the front of the heater. Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal, wood or

Summary of the content on the page No. 12

CLEARANCES / HEIGHT REQUIRMENTS C B A Figure 6 - Placing Stove in Alcove Tested Minimum Alcove Dimensions Height From Hearth Width Depth A B C VF20 38½"  3" 36" VF30  " 34" 36" Note: Maintain minimum side and back clearances when placing stove in alcove. 1 58D6002 ON OFF

Summary of the content on the page No. 13

LOGS LOGS PILOT REMOTE CONTROL OFF LOGS PILOT REMOTE CONTROL OFF REMOVING UNIT FROM CRATE 1. Remove two (2) straps. See Figure 7. Plastic Straps Bag 2. Open plastic bag and slide to bottom of unit. See Figure 8. 3. Lift up on ash lip and pivot down to open control door. See Figure 9. 4. L i f t u p o n f r o n t . P i v o t b o t t o m o f f r o n t o u t . R e m o v e front. See Figure 9. 5. Lift screen to remove. 6. Remove l

Summary of the content on the page No. 14

CONNECTING THE GAS NOTICE: A qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes. Use new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (Listed on Data Plate) at the maximum flow rate (BTU/Hr). Undue pressure loss will occur i

Summary of the content on the page No. 15

CHECk ING GAS PRESSURE and CONNECTING REMOTE RECEIVER The heater gas inlet connection is 3/8" NPT at the valve. The inlet is located on left side of stove. Remove front control Connecting directly to an unregulated plate to better access the inlet. propane/L.P.G. tank can cause an W h e n t i g h t e n i n g u p t h e j o i n t t o t h e v a l v e , h o l d t h e v a l v e s e c u r e l y explosion. with a wrench to prevent movem

Summary of the content on the page No. 16

ELECTRICAL WIRING (MILLI-VOLT) The milli-volt valve is a self-powered combination gas con trol THAT DOES NOT REQUIRE 110 VAC TO OPERATE. ODS Pilot Label all wires prior to On/Off disconnection when Switch servicing controls. ODS Wiring errors can cause Pilot improper and dangerous Wall operation. Verify proper Switch Millivolt operation after servicing. Valve On/Off 3 Switch Spade Terminal 1 2 Optional Wall Switch or CONNECTION Remote 1 = TP 2 = TP, TH 3 = TH Switch Figure 13

Summary of the content on the page No. 17

PILOT REMOTE CONTROL OFF LOG PLACEMENT Before you begin — This unit is supplied with four ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers. The positioning of the logs are critical to the safe and clean operation of this heater. Sooting and other problems may result

Summary of the content on the page No. 18

PILOT REMOTE CONTROL OFF LOG PLACEMENT VF20 INSTALLING LOGS ON GRATE (See Figure 15) 1. Install back log (#1) on back of burner assembly . 2. Install front log (#2) on 2 pegs on burner assembly . Figure 15 - Installing Logs to Grate (VF20) ROCk WOOL INSTALLATION (VF30 UNITS ONLY) 1. Break rock wool into dime-sized pieces. ➞ 2. Place rock evenly across rock wool tray and front burner as shown in Figure 16. • Rock wool depth must not be more than 1". • D

Summary of the content on the page No. 19

FLAME APPEARANCE Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. CHECk ING PILOT FLAME The pilot flame must always be present when the heater is in operation. It should just touch the top of the ther- mocouple tip for natural. See Figure 17 for correct pilot flame. If the pilot flame does not touch the thermocouple, then the bu

Summary of the content on the page No. 20

PILOT REMOTE CONTROL OFF FLAME APPEARANCE CHECk ING BURNER FLAME In normal operation at full rate after 15 minutes, the following flame appearances should be observed: The left and right rear flames should be yellow and extend 1"-2" above middle logs. The yellow flames should not contact the logs. There should be glowing embers on the front surface of the middle log. Note: The flames and embers will be an opaque orange color during the burn off time. M


Alternative user manuals
# User manual Category Download
1 Monessen Hearth Double Door VFCS20DPV User manual Oven 0
2 Monessen Hearth Double Door VFCS30DNV User manual Oven 1
3 Monessen Hearth Double Door VFCS30DPV User manual Oven 0
4 Edelbrock 17008 User manual Oven 0
5 3Com User manual Oven 1
6 ADIC 5.4 User manual Oven 1
7 AEG BC3000001 User manual Oven 527
8 AEG B3101-5-M User manual Oven 328
9 AEG BP7614000 User manual Oven 73
10 AEG BS7304001M User manual Oven 103
11 AEG BP5013001M User manual Oven 143
12 AEG BP5003001 User manual Oven 96
13 AEG BP8314001 User manual Oven 33
14 AEG B 60 D User manual Oven 23
15 AEG COMPETENCE B4101-4 User manual Oven 1204