Friedrich 115 Volts US10 user manual

User manual for the device Friedrich 115 Volts US10

Device: Friedrich 115 Volts US10
Category: Air Conditioner
Manufacturer: Friedrich
Size: 2.11 MB
Added : 3/11/2013
Number of pages: 61
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Friedrich 115 Volts US10. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Friedrich 115 Volts US10.

For your convenience

If looking through the Friedrich 115 Volts US10 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Friedrich 115 Volts US10 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Friedrich 115 Volts US10 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Friedrich 115 Volts US10 User manual - Online PDF
Advertisement
« Page 1 of 61 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Friedrich 115 Volts US10 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Friedrich 115 Volts US10. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation & Operation Guide
Thru-the-Wall Series
115 Volts UE08 US08 US10 US12
230 Volts US10 UE10 US12 UE12
Model information can be found on the name plate on the front of the unit.
To register your application, complete and mail the enclosed registration card, or
register on-line at www.friedrich.com (USA only).
For your future convenience, record the model information here.
MODEL NUMBER SERIAL NUMBER PURCHA

Summary of the content on the page No. 2

Safety Precautions Safety Precautions .............3 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for Electrical Data service at all. Electric

Summary of the content on the page No. 3

Safety Precautions Safety Precautions To prevent injury and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction can cause harm or damage. The seriousness is classified by the following indications. WARNING : This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION : properties only. Meanings of symbols used in this manual are as shown below. Never do th

Summary of the content on the page No. 4

CAUTION CAUTION When the air filter is to be Do not clean the air When the unit is to be conditioner with water. cleaned, switch off, and turn removed, do not touch the off the breaker. metal parts of the unit. • They are sharp and may cause • Water may enter the unit and • Since the fan rotates at high degrade the insulation. It may an injury. speed during operation, it may cause an electric shock. cause an injury. Do not put a pet or house Do not use for special Do not operate switches plant

Summary of the content on the page No. 5

Electrical Data Electrical Data Electrical Data(For 115V model) Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut or remove the Use 15 AMP time Parallel grounding prong delay fuse or 15 AMP type from the plug. circuit breaker. Power supply cord with Standard 125V, 3-wire grounding 3-prong grounding plug receptacle rated 15A, 125V AC USE OF EXTENSION CORDS Because of potential safety hazards, do not use an extension cord. Electrical Data(For 230/208V model)

Summary of the content on the page No. 6

About the Controls on the Air Conditioner The controls will look like one of the following: Controls – Cooling Only Models Off - Turns air conditioner off. Med Fan Only - Med speed fan operation without cooling. Low Fan Only - Low speed fan operation without cooling. High Cool - Cooling with high speed fan operation. Med Cool - Cooling with med speed fan operation. Low Cool - Cooling with low speed fan operation. This automatically controls the temperature of the indoor air. Turn the knob clockw

Summary of the content on the page No. 7

About the Controls on the Air Conditioner The controls will look like one of the following: Controls – Cooling & Heating Off - Turns the air conditioner off. Fan Only - The low fan speed operation without cooling/heating. Low Cool - Cooling with the low speed fan operation. High Cool - Cooling with the high speed fan operation. Low Heat - Heating with the low speed fan operation. High Heat - Heating with the high speed fan operation. Turn the Temperature Knob to the desired setting. The central

Summary of the content on the page No. 8

Additional controls and important information. Ventilation Control Push the lever to the "CLOSE" position to cool, heat or recirculate room air only. Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room. This feature is best used in conjunction with the FAN ONLY position. PULL OPEN / PUSH CLOSE Air Direction The direction of air can be controlled by adjusting the horizontal and vertical louvers. • HORIZONTAL AIR-DIRECTION CONTROL The horizontal air direction is ad

Summary of the content on the page No. 9

About the Controls on the Air Conditioner Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. Air Filter Cleaning The air filter should be checked at least twice a month to see if cleaning is necessary. Trapped particles in the filter will build up and block the airflow. This reduces the cooling capacity and can also cause an accumulation of frost on the cooling coils. If the filter becomes torn or damaged you should replace immediately. Replacement filt

Summary of the content on the page No. 10

Features Learning part name prior to installation will help you understand the installation procedure. Features The Unit 1 5 7 3 6 2 4 11 8 9 10 13 14 12 15 The Sleeve with the Rear Grille (sold separately) 17 16 1. CABINET 11. EVAPORATOR 2. HORIZONTAL AIR DEFLECTOR 12. CONDENSER (Vertical Louver) 13. COMPRESSOR 3. VERTICAL AIR DEFLECTOR 14. BASE PAN (Horizontal Louver) 15. BRACE 4. AIR DISCHARGE 16. SLEEVE ASSEMBLY 5. FRONT GRILLE (Including Expanded Aluminum Rear grille) 6. INLET GRILLE (Air I

Summary of the content on the page No. 11

Features and Installation Installation Remove packing sheet from the back of the sleeve, and INSTALLATION HARDWARE packing corner and blue tape from the air conditioner. 2 1 INSTALLATION REQUIREMENTS 4 If you use an existing wall sleeve, you should measure its dimensions. 2 Size options Install the new air conditioner according to these 5 installation instructions to achieve the best 7 performance. All wall sleeves used to mount the new air conditioner must be in good structural 8 3 condition an

Summary of the content on the page No. 12

NOTE: All wall sleeves used to mount the new Air INSTALLATION Conditioner must be in sound structural condition CAUTION and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the We strongly recommend the removal of the Air Conditioner. old wall sleeve and the installation of a new Remove old air conditioner from existing wall FRIEDRICH USC Wall Sleeve. 2 sleeve. If you decide to keep the existing wall sleeve, you have to redirect the louvers at the ba

Summary of the content on the page No. 13

Features and Installation Install the new unit into the wall sleeve. PROCEDURE A 4 If you are using the new sleeve supplied with To assemble trim, snap the tab of each piece 1 5 your unit, skip to step 3. Otherwise, install the into the slot of the other piece as shown below. plastic grille from the kit. Cut the plastic grille to Slide trim over the front of the air conditioner 25-1/2" wide and 15-1/4" high. Place the until trim is flush with sleeve as shown below. plastic grille to the inside o

Summary of the content on the page No. 14

Remove the backing from the Horizontal PROCEDURE B 4 3 5 3 Insulation strip 1 / " x / " x 27 / " and attach 8 8 16 Redirect the louvers at the back of the wall that to the inside bottom of the sleeve as shown 1 sleeve to 60° angle as shown in the FIG 8. The below. Remove the backing from the Around 3 3 1 use of pliers is recommended. Insulation strip 1 / " x / " x 61 / " and attach that 8 4 2 to the inside front of the sleeve as shown below. 5 7 / " 16 60° 60° Rear Louvers Around Insulation Hori

Summary of the content on the page No. 15

Features and Installation PROCEDURE B To assemble trim, snap the tab of each piece 8 into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below. Trim (2 ea) Wall FIG. 14 CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When hand

Summary of the content on the page No. 16

Remove the backing from the Horizontal PROCEDURE C 4 3 3 3 Insulation strip 1 / " x 1 / " x 27 / " and attach 8 8 16 Redirect the louvers at the back of the wall that to the inside bottom of the sleeve as shown 1 sleeve to 60° angle as shown in the FIG 15. below. Remove the backing from the Around 3 3 1 The use of pliers is recommended. Insulation strip 1 / " x 1 / " x 61 / " and attach that 8 8 2 to the inside front of the sleeve as shown below. 13 7 / " 16 60° 60° Rear Louvers (Top View) Aroun

Summary of the content on the page No. 17

Features and Installation To assemble trim, snap the tab of each piece PROCEDURE C 9 into the slot of the other piece as shown below. Remove the backing from the 13" shim strips Slide trim over the front of the air conditioner 7 and attach them as shown below in Fig. 22. until trim is flush with sleeve as shown below. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve. 1" high 3 / " High 4 FIG. 21 Trim (2 ea) Shim (2EA) Wall 6" 6" FIG. 22 Install the new un

Summary of the content on the page No. 18

Before you call for service... Troubleshooting Tips Save Time and Money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off. • Water will collect in the base pan during high humidity

Summary of the content on the page No. 19

Friedrich Air Conditioning-Co. P.O. Box 1540 San Antonio, TX 78295-1540 (210) 357-4400 THRU-THE-WALL LIMITED WARRANTY FIRST YEAR ANY PART: If any Part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units will be the responsibility of the owner. This

Summary of the content on the page No. 20

Memo 20


Alternative user manuals
# User manual Category Download
1 Friedrich 000 BTU'S User manual Air Conditioner 23
2 Friedrich 18 User manual Air Conditioner 11
3 Friedrich 115 Volts UE08 User manual Air Conditioner 7
4 Friedrich 2003 User manual Air Conditioner 6
5 Friedrich 115 Volts US12 User manual Air Conditioner 12
6 Friedrich 2006 User manual Air Conditioner 5
7 Friedrich 1883 User manual Air Conditioner 8
8 Friedrich 000 BTU/h User manual Air Conditioner 1
9 Friedrich 115 Volts US08 User manual Air Conditioner 2
10 Friedrich 2007 User manual Air Conditioner 2
11 Friedrich 2008 User manual Air Conditioner 2
12 Friedrich 230 Volts US10 User manual Air Conditioner 7
13 Friedrich 2009 User manual Air Conditioner 3
14 Friedrich 24 User manual Air Conditioner 4
15 Friedrich 49 User manual Air Conditioner 1
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21