American Power Conversion Smart-UPS VT user manual

User manual for the device American Power Conversion Smart-UPS VT

Device: American Power Conversion Smart-UPS VT
Category: Power Supply
Manufacturer: American Power Conversion
Size: 14.1 MB
Added : 3/12/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Power Conversion Smart-UPS VT. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Power Conversion Smart-UPS VT.

For your convenience

If looking through the American Power Conversion Smart-UPS VT user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Power Conversion Smart-UPS VT on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Power Conversion Smart-UPS VT to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Power Conversion Smart-UPS VT User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Power Conversion Smart-UPS VT but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Power Conversion Smart-UPS VT. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Smart-UPS VT and
XR Battery Enclosure
10-30 kVA
208/220 V
Operation Manual

Summary of the content on the page No. 2

Summary of the content on the page No. 3

® Smart-UPS VT and XR Battery Enclosure10-30 kVA 208/220 V Operation Manual IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS This manual contains important instructions for the SUVT series that should be followed during installation and maintenance of the UPS and Batteries Smart-UPS® VT and XR Battery Enclosure 10-30kVA, 208V Operation Guide – 990-1599 1

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Contents Safety ......................................................................1 IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . 1 Symbols used in this guide . . . . . . . . . . . . . . . . . . . . . . . . . 1 Environmental symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Operation ................................................................3 Introduction . . .

Summary of the content on the page No. 6

Display Messages/Troubleshooting . . . . . . . . . . . . . . . . . . . . . 17 Display messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Front Panel Removal/Installation . . . . . . . . . . . . . . . . . . . . . . . 20 Front Panel removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Total-Power-Off Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Restart

Summary of the content on the page No. 7

Warranty ...............................................................34 LIMITED FACTORY WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . 34 APC product covered . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Terms of warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Non-transferable warranty extends to first purchaser for use . 34 Assignment of warranties . . . . . . . . . . . . . . . . . . . . . . . . . 35 Drawings, descriptions . . . . . . . . . . .

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Safety IMPORTANT SAFETY INSTRUCTIONS This guide contains important instructions that should be followed when handling the UPS, Battery Enclosures, and Batteries. Symbols used in this guide WARNING! Risk of electric shock. CAUTION! Read this information to avoid equipment damage. Indicates important information. Note Indicates that more information is available on this subject in a different section of this manual. Indicates that more information is available on the same subject in a different

Summary of the content on the page No. 10

Safety – IMPORTANT SAFETY INSTRUCTIONS General safety Two people to lift components weighing between 40 - 70 lbs / 18 - 32 kg. Indicates that a switch or current protection device is in the ON position. Indicates that a switch or a breaker is in the OFF position. WARNING! Hazardous electrically-charged parts inside the UPS are energized from the battery supply even when the AC power is disconnected. Follow Total-Power-Off Procedure to completely de-energize the system. For configurations incl

Summary of the content on the page No. 11

Operation Introduction ® Welcome to the Operation Manual covering the Smart-UPS VT UPS and the Extended Run Battery Enclosure (XR Battery Enclosure). This manual provides you with a detailed description of restart, operation, and troubleshooting. Separate manuals are available on: • Receiving and Unpacking part no. 990-1747. • Site preparation and Installation part no. 990-1598. For documentation on Maintenance Bypass Panels with/without Power Distribution Unit, see product-specific manuals.

Summary of the content on the page No. 12

BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT N o a en C AP9619 Network Management Card EM AP9619 etw rk Man gem t ard EM BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT BATTERY UNIT Mode l: Mode l: Mode l: Model: Model: Model: Model: Model: Model: Model: Model: Model: Model: Model: Model: Mod

Summary of the content on the page No. 13

Operation – The Smart-UPS VT Family Range Serial number The serial number is available on the type label on the rear side of the UPS. Type label Hotline in US/Canada/LAM: +1 800 800 4APC Hotline in EMEA: +353 91 70 2000 Worldwide Support numbers: www.apcc.com/support/service/geomap_world.dfm Model Battery Capacity Unit Serial No APC SKU Apparent/ Rated Input Current Rated Output Current Battery Current @– 192V DC Active Power APC Smart-UPS VT 10kVA 208V 7.2Ah SUVT10KF1B2S w/1 Batt. Modu

Summary of the content on the page No. 14

Operation Modes In a stand-alone installation, the UPS has four different operating modes. If the installation includes a Maintenance Bypass Panel, bypass mode and test mode will also be available. Normal operation During normal operation, the UPS converts utility power to conditioned power for the connected load. Battery operation During battery operation, the UPS provides power to the connected load from its internal and (if applicable) external batteries for a finite period. The UPS trans

Summary of the content on the page No. 15

Operation – Operation Modes Wrap-around maintenance bypass The UPS can be connected to an external Maintenance Bypass Panel. When activated, this panel bypasses the entire UPS Enclosure (only possible with an optional APC Maintenance Bypass Panel), feeding utility power directly to the load. An activated wrap-around Maintenance Bypass Panel completely isolates the UPS and allows maintenance to be performed - including a replacement of the entire UPS. 990-1599B Smart-UPS® VT 10-30 kVA, 208/22

Summary of the content on the page No. 16

The Display Introduction CAUTION! The display provides access to more functions than described in this manual. Those functions should not be accessed without the assistance of APC Customer Support in order to avoid unwanted load impacts. For APC World-wide Customer Support, refer to rear cover of this manual. Five navigation keys are used to select and open menu items, to access Four Light Emitting Diode (LED) Liquid Crystal information, change system parameters, indicators report the op

Summary of the content on the page No. 17

Navigation Menu-driven user functions If you get beyond the functions described in the menu tree, do not proceed. Press ESC to go back. Control Turn load off UPS into bypass Status Vin Vbyp Vout Iin lbyp Iout kVA & kW Frequencies Load & Bat Overview Batteries Chrg xxx% Load xxx% xxxVin Runtime Alarm thresholds Main Menu Control Display Clock Setup Status Diags Setup Help Settings Logging Alarms View log Logging Logging View statistics Beeper setup Display Display setup Contrast Diags Language

Summary of the content on the page No. 18

Operation – Navigation Basic display navigation principles On the display, press ESC until you get to the Overview Screen, which provides you with basic system status information. Press UP, DOWN arrows to navigate the selector arrow and view all sub-menu screens. Chrg 100% Load 000% 120Vin 000Vout 60Hz Runtime: 0hr 0m Overview Screen Press ENTER to open the Main Menu screen. From here, you command, configure, and monitor the system. Control Logging Status Display Setup Diags Help Main Menu C

Summary of the content on the page No. 19

Operation – Navigation Switch load ON: • From the Main Menu, select Control and press ENTER • Use UP/DOWN key to navigate to Turn Load On, and press ENTER • Select YES, Turn Load On Switch into bypass: • From the Main Menu, select Control and press ENTER • Use UP/DOWN key to navigate to UPS into Bypass and press ENTER • Use UP/DOWN key to navigate to YES, UPS into bypass, and press ENTER Switch out of bypass: • From the Main Menu, select Control and press ENTER • Select UPS out of Bypass and

Summary of the content on the page No. 20

Operation – Navigation Load and batteries. Load: Percentage of the load in relation to the total UPS capacity. Bat Voltage: shows either the positive or negative half of the battery voltage (the lower value of the two will appear). Bat Cap: Percentage charge on the batteries in relation to the total battery capacity. Runtime: The predicted runtime at the current load. Batteries. Bat AmpHr: Battery capacity, including both external and internal batteries. UPS Temp: The highest external battery


Alternative user manuals
# User manual Category Download
1 American Power Conversion 100 User manual Power Supply 0
2 American Power Conversion 120 User manual Power Supply 0
3 American Power Conversion 110, 120, 230 User manual Power Supply 0
4 American Power Conversion 10000 VA User manual Power Supply 1
5 American Power Conversion 1000, 1100, 1400 User manual Power Supply 2
6 American Power Conversion 110Vac User manual Power Supply 0
7 American Power Conversion 1400XLT User manual Power Supply 0
8 American Power Conversion 1050 User manual Power Supply 0
9 American Power Conversion 10-40kW 208/480V User manual Power Supply 0
10 American Power Conversion 2200 VA User manual Power Supply 0
11 American Power Conversion 2200XLT User manual Power Supply 0
12 American Power Conversion 208/220 User manual Power Supply 0
13 American Power Conversion 20000 VA User manual Power Supply 3
14 American Power Conversion 2200VA 3U User manual Power Supply 0
15 American Power Conversion 230 VAC User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2