B&K 1651A user manual

User manual for the device B&K 1651A

Device: B&K 1651A
Category: Power Supply
Manufacturer: B&K
Size: 2.45 MB
Added : 9/1/2014
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for B&K 1651A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with B&K 1651A.

For your convenience

If looking through the B&K 1651A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual B&K 1651A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual B&K 1651A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
B&K 1651A User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual B&K 1651A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to B&K 1651A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1





INSTRUCTION

MANUAL
MODELS 1651A & 1652

MODELOS 1651A & 1652

El Manual de la Instrucción



Triple Output
DC POWER SUPPLY

FUENTES DE PODER
De Triple Salida DC







1

Summary of the content on the page No. 2

TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed high voltage is present. An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can produce a lethal current under certain conditions. Higher voltages are

Summary of the content on the page No. 3

Instruction Manual Triple Output DC POWER SUPPLY 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 3

Summary of the content on the page No. 4

TABLE OF CONTENTS Page Page TEST INSTRUMENT SAFETY........inside front cover Parallel Tracking Operation...................................... 22 INTRODUCTION.........................................................1 Fixed 5 V Power Supply Operation.......................... 25 FEATURES ...................................................................3 APPLICATIONS.................................................... 29 SPECIFICATIONS.......................................

Summary of the content on the page No. 5

INTRODUCTION The B & K-Precision Models 1651A & 1652 Triple Output The fixed 5V supply is ideal for powering digital logic DC Power Supplies are high quality, general purpose dc power circuitry. The 0-4 amp capacity allows the supply to be used sources. They provide two supplies with a 0-24 volt dc output for large circuits. Built-in overload protection automatically and one with a fixed 5 volt dc output. The 0-24V supplies are limits the current output to a maximum of 4 amps.

Summary of the content on the page No. 6

INTRODUCTION______________________________________________________________________________________ The features and versatility of these units, especially the The same features that make the Model 1651A and 1652 a triple output and tracking features, make them an ideal good choice for an engineering lab also make them a good choice general purpose power supply for engineering lab for most other solid state electronic applications. These applications. They can serve as a single or mul

Summary of the content on the page No. 7

FEATURES TRIPLE OUTPUT SINGLE 0-24V 1 AMP SUPPLY Operates as three separate power supplies. Each has floating Parallel tracking feature allows use of “A” and “B” output and is completely isolated from the other two. supplies as a 0-to-24 V supply with a 1 amp current capacity (through “A” output terminals). ONE FIXED 5V SUPPLY CONSTANT VOLTAGE OR CONSTANT CURRENT 0-to-4 amp fixed 5 volt supply is ideal for use with most The “A” and “B” supplies provide regulated dc v

Summary of the content on the page No. 8

FEATURES__________________________________________________________________________________________ REVERSE POLARITY PROTECTION ISOLATED OUTPUT Either polarity may be floated or grounded Prevents damage to power supply from external voltage of reverse polarity. OVERLOAD PROTECTION Fully adjustable current limiting (from 6% to 100% HOOK-UP CABLES of maximum output current) for “A” and “B” supplies Supplied with three sets of red and black hook-up leads. protects circuit

Summary of the content on the page No. 9

SPECIFICATIONS “A” AND “B” SUPPLIES Constant Current Operation: Output Voltage Range: Adjustable Current Limits: ≤30mA to ≥500mA 0V to 24VDC (0 ± 100mV) Current Regulation: Output Current Limit Range: Load: ≤0.2% + 6mA. 0 to 0.5A. Line (108 – 132V): ≤0.2% + 3mA. Constant Voltage Operation: Ripple Current and Noise: ≤3mA rms. Voltage Regulation: Metering (“A” & “B” only): Load: ≤0.01% + 3mV Line (108 – 132V):

Summary of the content on the page No. 10

SPECIFICATIONS_____________________________________________________________________________________ Temperature Range FIXED 5V SUPPLY & Humidity: Output Voltage: 5V ± 100mV. Operation: 0°C to 40°C <80% R.H. Storage: -20°C to 60°C <70% Maximum Current: ≥4A. R.H. Load Regulation: ≤10mV. Dimensions (HxWxD): 4.5 x 11.75 x 10.375” Line Regulation 108 – 132 V: ≤5mV (114 x 298 x 264 mm)

Summary of the content on the page No. 11

CONTROLS AND INDICATORS 1. POWER Switch. Turns power on and off. b. When the switch is in the middle position, the unit is in the PARALLEL TRACKING mode. In 2. Power ON light. Red LED lights to indicate a power on this mode the “A” and “B” supplies are wired condition. together in parallel and both the maximum current and voltage are set using the “A” 3. GND Terminal (Green). Earth and Chassis Ground. controls. The “A” and “B” outputs can be used as two indiv

Summary of the content on the page No. 12

CONTROLS AND INDICATORS__________________________________________________________________________ Figure 1. Front panel controls and indicators 8

Summary of the content on the page No. 13

__________________________________________________________________________CONTROLS AND INDICATORS 10. CURRENT Control. Adjusts current limit of “A” “B” SUPPLY CONTROLS AND INDICATORS supply in constant voltage mode. Adjusts constant 14. VOLTAGE Control. Adjusts the output voltage of the current value of “A” supply in constant current mode. “B” supply when the INDEPENDENT mode is selected. Adjusts the constant current value of the “B” supply Voltage can be read on the V Meter when

Summary of the content on the page No. 14

CONTROLS AND INDICATORS__________________________________________________________________________ FIXED 5V SUPPLY TERMINALS AND INDICATOR REAR PANEL CONTROLS 19. “+” Terminal (Red). Positive polarity output terminal 22. LINE VOLTAGE SELECT Switches. Combination for FIXED 5V supply. settings allow Universal Power Operation; 20. “-“ Terminal (Black). Negative polarity output terminal 23. Line Cord Receptacle. Fuse. for FIXED 5V supply. 21. OVERLOAD Indicator. Lights when

Summary of the content on the page No. 15

__________________________________________________________________________CONTROLS AND INDICATORS Figure 2. Rear panel controls. 11

Summary of the content on the page No. 16

OPERATING INSTRUCTIONS SAFETY PRECAUTIONS EQUIPMENT PRECAUTIONS Avoid using the power supply in ambient temperatures CAUTION above +40° C. Always allow sufficient air space around the heat sink at the rear of the power supply for effective Avoid contacting the heat sink at the rear of the power radiation to prevent internal heat build-up. supply. When the unit is providing large amounts of Although the power supply is protected against reverse polarity damage, the cir

Summary of the content on the page No. 17

___________________________________________________________________________OPERATING INSTRUCTIONS Hook-up 1. Observe proper polarity. If the circuit being powered is not equipped with reverse polarity protection, 3. Set the INDEPENDENT/TRACKING mode switch to damage to the circuit can result from reverse polarity. the right position so that the power supply is in the Use color coded hook-up leads, for convenience in INDEPendent operating mode. identifying polarity, red for (+)

Summary of the content on the page No. 18

OPERATING INSTRUCTIONS___________________________________________________________________________ Figure 3. Independent operation grounding possibilities (sheet 1 of 2) 14

Summary of the content on the page No. 19

___________________________________________________________________________OPERATING INSTRUCTIONS Figure 3. Independent operation grounding possibilities (sheet 2 of 2) 15

Summary of the content on the page No. 20

OPERATING INSTRUCTIONS___________________________________________________________________________ 8. If the load current exceeds the preset current limit, the CONSTANT CURRENT indicator will light. In this case, the power supply automatically switches to the constant current mode and further rotation of the VOLTAGE control will not increase the output voltage. Setting Current Limit 1. Determine the maximum safe current for the device to be powered. 2. Tempora


Alternative user manuals
# User manual Category Download
1 B&K 1652 User manual Power Supply 1
2 B&K 1785B User manual Power Supply 1
3 B&K 0-3A User manual Power Supply 1
4 B&K 1786B User manual Power Supply 0
5 B&K 1787B User manual Power Supply 2
6 B&K 1788 User manual Power Supply 1
7 B&K 1794 User manual Power Supply 1
8 B&K 0-30V User manual Power Supply 2
9 Sony AC U50A User manual Power Supply 5
10 Sony AC LS1 User manual Power Supply 2
11 Sony NP-FM30 User manual Power Supply 35
12 Sony NP FX101 User manual Power Supply 1
13 Sony NH-AAA-DA User manual Power Supply 2
14 3Com 3645A User manual Power Supply 0
15 3Com 3CNJPSE24 User manual Power Supply 2