Tripp Lite PowerVerter APSRM4 user manual

User manual for the device Tripp Lite PowerVerter APSRM4

Device: Tripp Lite PowerVerter APSRM4
Category: Power Supply
Manufacturer: Tripp Lite
Size: 0.57 MB
Added : 3/12/2014
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tripp Lite PowerVerter APSRM4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tripp Lite PowerVerter APSRM4.

For your convenience

If looking through the Tripp Lite PowerVerter APSRM4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tripp Lite PowerVerter APSRM4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tripp Lite PowerVerter APSRM4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tripp Lite PowerVerter APSRM4 User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tripp Lite PowerVerter APSRM4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tripp Lite PowerVerter APSRM4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual
®
PowerVerter
APS Series DC-to-AC
Inverter/Charger
Input Output
1111 W. 35th Street, Chicago, IL 60609 USA
Invert: 12 VDC 120V, 60 Hz. AC
Customer Support: (773) 869-1234
Charge: 120V, 60 Hz. AC 12 VDC
www.tripplite.com
Reliable Emergency Backup Power
Congratulations! You've purchased the most advanced, feature-rich Inverter/Charger designed as an alternative energy source during utility
power failures. Tripp Lite APS Inverter/Chargers keep your equipment up and productive throug

Summary of the content on the page No. 2

Important Safety Instructions SAVE THESE INSTRUCTIONS! This manual contains important instructions and warnings that should be followed during the installation, operation and storage of this product. Location Warnings • Install your Inverter/Charger in a location or compartment that minimizes exposure to heat, dust, direct sunlight and moisture. • Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit and could cau

Summary of the content on the page No. 3

Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use. 1 Configuration DIP Switches: optimize Inverter/Charger 7 Resettable Circuit Breakers: protect your Inverter/Charger operation depending on your application. See Configuration against damage due to overload or charger failure. See Operation section for setting instructions. section for resetting instructions. 2 Operating Mode Switch: controls Inverter/Charger

Summary of the content on the page No. 4

Operation “INV” (Inverting) Yellow LED: This light will Switch Modes ILLUMINATE CONTINUOUSLY whenever After configuring, mounting and connecting your Inverter/Charger, connected equipment is receiving battery-supplied, you are able to operate it by switching between the following inverted AC power (in the absence of a operating modes as appropriate to your situation: utility/generator source or in over/under voltage AUTO/REMOTE: Switch to this mode when you situations). This light will be off wh

Summary of the content on the page No. 5

(continued) Operation Resetting Your Inverter/Charger to Restore AC Power Your Inverter/Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your electrical system. To restore normal functioning: Overload Reset: Switch operating mode switch to “DC OFF” and remove some of the connected electrical load (ie: turn off some of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operatin

Summary of the content on the page No. 6

(continued) Configuration Group B DIP Switches B2 B1 Select AC Sharing—OPTIONAL Your Inverter/Charger features a high-output battery charger that can draw a significant amount of AC power from your utility source or generator when charging at its maximum rate. If your unit is supplying its full AC power rating to its connected heavy electrical loads at the same time as this high charging occurs, the AC input circuit breaker could trip, resulting in the complete shut off of pass-through utility

Summary of the content on the page No. 7

(continued) Configuration Set Battery Charge Conserver (Load Sense) Dial—OPTIONAL In order to save battery power, the unit’s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances (the electrical load). When the unit detects a load, it automatically turns its inverter function on. Users may choose the minimum load the Inverter/Charger will detect by adjusting the Battery Charge Conserver Dial (see diagram). Using a small tool, turn the dial cl

Summary of the content on the page No. 8

Battery Selection Select Battery Type Select “Deep Cycle” batteries to receive optimum performance from your Inverter/Charger. Do not use ordinary car or starting batteries or batteries rated in Cold Cranking Amps (CCA). If the batteries you connect to the Inverter/Charger are not true Deep Cycle batteries, their operational lifetimes may be significantly shortened. If you are using the same battery bank to power the Inverter/Charger as well as DC loads, your battery bank will need to be appropr

Summary of the content on the page No. 9

Mounting WARNING! Mount your Inverter/Charger BEFORE DC battery and AC power connection. Failure to follow these instructions may lead to personal injury and/or damage to the Inverter/Charger and connected systems. Tripp Lite recommends permanent mounting of your Inverter/Charger as illustrated below. User must supply mounting hardware and is responsible for determining if the hardware and mounting surface are suitable to support the weight of the Inverter/Charger. Contact Tripp Lite if you requ

Summary of the content on the page No. 10

Battery Connection Connect your Inverter/Charger to your batteries using the following procedures: • Connect DC Wiring: Though your Inverter/Charger is a high-efficiency converter of electricity, its rated output capacity is limited by the length and gauge of the cabling running from the battery to the unit. Use the shortest length and largest diameter cabling (maximum 2/0 gauge) to fit your Inverter/Charger’s DC Input terminals (see table below). Shorter and heavier gauge cabling reduces DC

Summary of the content on the page No. 11

AC Input/Output Connection To avoid overloading your Inverter/Charger, match the power requirements of the equipment you plan to run at any one time (add their total watts) with the output wattage capacity of your Inverter/Charger model (see Specifications). Do not confuse “continuous” wattage with “peak” wattage ratings. Most electric motors require extra power at start-up (“peak wattage”) than required to run continuously after start- up, sometimes over 100% more. Some motors, such as in refri

Summary of the content on the page No. 12

Troubleshooting Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234 before returning your unit for service. SYMPTOM PROBLEMS CORRECTIONS No AC Output Unit is not properly connected to utility power Connect unit to utility power. (All Indicator Lights are OFF) Operating Mode Switch is set to “DC OFF” and AC input Set Operating Mode Switch to “AUTO/REMOTE” or “CHARGE ONLY”. is present. This is normal when the Ope

Summary of the content on the page No. 13

1111 W. 35th Street, Chicago, IL 60609 USA 773.869.1234 (USA) • 773.869.1212 (International) www.tripplite.com


Alternative user manuals
# User manual Category Download
1 Tripp Lite 120 User manual Power Supply 9
2 Tripp Lite 120V User manual Power Supply 26
3 Tripp Lite 1500RMXL2UA User manual Power Supply 15
4 Tripp Lite 120V Input, Line-Interactive UPS System SMART750USB User manual Power Supply 20
5 Tripp Lite 200305107 User manual Power Supply 0
6 Tripp Lite 1400VA User manual Power Supply 7
7 Tripp Lite 1500SLT User manual Power Supply 8
8 Tripp Lite 200204171 93-2036_EN User manual Power Supply 1
9 Tripp Lite 200904140 User manual Power Supply 1
10 Tripp Lite 200803016 95-2924 User manual Power Supply 1
11 Tripp Lite 2009XXXXX 93-1350_EN User manual Power Supply 1
12 Tripp Lite 220 User manual Power Supply 5
13 Tripp Lite 20KVA User manual Power Supply 10
14 Tripp Lite 2-Port In-Line PS/2 KVM Switch with Audio B032-002-R User manual Power Supply 11
15 Tripp Lite 240 User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2