American Power Conversion SYMF800KH user manual

User manual for the device American Power Conversion SYMF800KH

Device: American Power Conversion SYMF800KH
Category: Power Supply
Manufacturer: American Power Conversion
Size: 1.92 MB
Added : 11/5/2013
Number of pages: 54
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Power Conversion SYMF800KH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Power Conversion SYMF800KH.

For your convenience

If looking through the American Power Conversion SYMF800KH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Power Conversion SYMF800KH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Power Conversion SYMF800KH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Power Conversion SYMF800KH User manual - Online PDF
Advertisement
« Page 1 of 54 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Power Conversion SYMF800KH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Power Conversion SYMF800KH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
®
Symmetra MW
800 kW
400 V
ON OFF EMO

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Contents Safety ......................................................................1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Symbols used in this guide . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 System Overview......................................................3 UPS Sections . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

External Bypass Static Switch Wiring . . . . . . . . . . . . . . . . . . . . 18 Top cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Bottom cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Communication cable overview . . . . . . . . . . . . . . . . . . . . . . . . 21 Relay Board (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Location of optional Relay Board . . . . . . . . . . . . . . . . . . . . 22 Communication

Summary of the content on the page No. 5

IT Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Reference to IEC 60364-4-41 413.1.5 . . . . . . . . . . . . . . . . . 39 Protective devices in IT systems . . . . . . . . . . . . . . . . . . . . . 40 Symmetra MW 800 kW 3 × 400/230 V Installation - 990-1510D iii

Summary of the content on the page No. 6

Summary of the content on the page No. 7

Safety IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS This guide contains important instructions for SYMF800KH that should be followed when handling the UPS, External Bypass Static Switch, Battery Enclosures, and Batteries. Symbols used in this guide WARNING! Indicates an electrical hazard, which, if not avoided, could result in injury or death. CAUTION! Indicates a hazard, which, if not avoided, could result in injury or death. Indicates important information. Note Indicates that mor

Summary of the content on the page No. 8

Safety: IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Installation safety Press the optional EPO (Emergency Power Off) button to switch off all AC and DC power supply to connected equipment in the room and to cut off the load supply. The EPO EPO is typically located on a wall in the room in which the UPS is installed. See “Communication cable overview” section for information on how to wire the UPS to the EPO. WARNING! Before starting installation, check and test that all AC and DC

Summary of the content on the page No. 9

System Overview UPS Sections Serial number The serial number is stated on the type label behind the finishing panel above the display unit. Remove finishing panel to see serial number. Inverter Section The Inverter Section regulates the UPS output and operates from battery power in the event of utility input loss. Control Section The Control Section controls and monitors the UPS and the Mains Static Switch Module (incorporated in the Control Section). Input/Output Section The Input/Output Sec

Summary of the content on the page No. 10

1067 mm Configurations The UPS system can be configured in two ways. The Inverter Section can be placed either to the left or to the right of the Control Section. The two configurations are shown below. Configuration 1 (Inverter Section placed to the left) ON OFF EMO Inverter Section Control Section Input/Output Section Width: Width: Width: 1690 mm 1012 mm 1014 mm Total width of UPS sections: 3716 mm Weight: Without Power Modules: 3548 kg With Power Modules: 4230 kg 4 Symmetra MW 800 kW 3 × 40

Summary of the content on the page No. 11

1067 mm System Overview: Configurations Configuration 2 (Inverter Section placed to the right) Input/Output Section Control Section Inverter Section Width: Width: Width: 1014 mm 1012 mm 1690 mm Total width of UPS sections: 3716 mm Weight: Without Power Modules: 3548 kg With Power Modules: 4230 kg Symmetra MW 800 kW 3 × 400/230 V Installation - 990-1510D 5 2032 mm

Summary of the content on the page No. 12

External Bypass Static Switch The External Bypass Static Switch (External Bypass SSW) transfers the load (manually or automatically) from the UPS to an alternate source without interrupting the supply to the load. ~ ~ 2032 mm 1067mm External Bypass Static Switch Width: 1016 mm Weight: 1 MW: 460 kg Serial number The serial number is stated on the type label behind the finishing panel above the display unit. Remove finishing panel to see serial number. 6 Symmetra MW 800 kW 3 × 400/230 V Install

Summary of the content on the page No. 13

Electrical Installation Electrical Wiring Principle See separate guide on parallel operation for wiring overview in parallel systems. See also Symmetra MW 800 kW 3 × 400/230 V Installation - 990-1510D 7 Maintenance Bypass Panel (MBP) Symmetra MW 6 MAINS Battery Breaker Box 1 Batteries 1 9 9 External Bypass Static Switch Battery Breaker Box 2 Batteries 2 6 1. MAINS SOURCE 3X400/230V TN-S (PROVIDED BY OTHERS). 8. DC CABLING SHOULD BE SEGREGATED FROM AC CABLING 2. Q1 - Q6 WITH 2NO/2NC AUXILIARY C

Summary of the content on the page No. 14

Electrical Installation: Electrical Wiring Principle External disconnection switches WARNING! The UPS has no internal manual disconnect devices to switch off external AC (Q1 and Q5) and DC (Q7 and Q8) input power. Ensure that disconnection devices are available as separate components for this installation. The installer must provide each external disconnection device for this UPS system with labels displaying the following text: “Isolate the Uninterruptible Power Supply (UPS) as instructed in

Summary of the content on the page No. 15

Top Cable Entry Preparing for top cable entry (Default) Cable entry in Top Cover of Input/Output Section. Top view  M6 Bolt 1.75 in / 1.75 in / 44.45 mm 44.45 mm DC DC 2.3 in / 58 mm cable cable entry entry AC IN cable AC OUT entry cable entry IN/OUT power cable (top entry)   BAT 1 BAT 2 Top view AC IN AC OUT L1 IN L1 OUT 92 93 L3 IN L3 OUT 90 95 L2 IN L2 OUT 91 94 L2 IN L2 OUT 92 L1 IN 93 L1 OUT 91 94 L3 IN L3 OUT 95 90 N N Loosen the 8 bolts in both cable entry covers (4 bolt

Summary of the content on the page No. 16

Electrical Installation: Top Cable Entry Battery cable connections (top cable entry) WARNING! Make sure that the battery breakers are open (OFF) prior to running the cables. CAUTION! Refer to the battery manufacturer’s installation manual. CAUTION! The minimum DC voltage rating of the battery supply over-current protective device is 500 V. Over-current protection for the battery circuit is required by national wiring rules. Note 10 Symmetra MW 800 kW 3 × 400/230 V Installation - 990-1510D

Summary of the content on the page No. 17

Electrical Installation: Top Cable Entry Top view of Input/Output Section M6 Bolt 1.75 in / 1.75 in / 44.45 mm 44.45 mm 2.3 in / 58 mm DC DC cable cable entry entry AC IN AC OUT cable entry cable entry IN/OUT power cable (top entry) Battery 1 Battery 2   (DC1 +/-) (DC2 +/-) BAT1- BAT2+ BAT1- BAT2+ L1 Out L1 In L2 In L2 Out  L3 In L3 Out BAT1+ BAT2— N N BAT1+ BAT2- Input/Output Section Feed the battery cables through the grommets  Connect cables from battery system.  Connect cabl

Summary of the content on the page No. 18

Battery 2 PE Battery 1 Electrical Installation: Top Cable Entry PE and AC cable connections (top cable entry)  Bonding Jumper (TN- systems) to Input Neutral  Bar Protective Earthing conductors (red) for Battery 2 & AC OUT Earthing conductor connected to suitable earth electrode TN- systems Output circuit grounding bar. Protective Earthing N N conductors (red) for Battery 1 & AC IN 1.75 in / 1.75 in / 44.45 mm 44.45 mm 2.3 in / 58 mm Feed the AC and PE cables through the top of Inp

Summary of the content on the page No. 19

Bottom Cable Entry Preparing for bottom cable entry Cable entry in bottom cover of Input/Output Section  Top view M6 Bolt DC DC 1.75 in / 1.75 in / cable cable 44.45 mm 44.45 mm entry entry 2.3 in / 58 mm AC IN AC OUT cable entry cable entry Top view Front view BAT 1 BAT 2 M14 M14 M14  M14 AC IN AC OUT M10 M10 M10 M10 90 L3 IN 95 L3 OUT  M10 L2 IN L2 OUT M10 M10 92 L1 IN 93 L1 OUT L1 IN L1 OUT 90 95 L2 IN L2 OUT 91 94 L3 IN L3 OUT 92 93 BAT 1 BAT 2 N N Top view AC IN AC OUT L3 IN

Summary of the content on the page No. 20

Electrical Installation: Bottom Cable Entry Preparation for bottom cable entry  a. Loosen bolts of both cable entry covers and remove. b. Drill holes for grommets for AC, DC, and Output circuit grounding electrode cable in areas shown. No drilling or cutting should take place inside the UPS. Note c. Install grommets. d. Remount covers. Interchange of AC IN busbars for bottom entry  a. Remove nuts from M14 bolts at busbars 90 and 92. b. Remove bolt, washer and fuse. c. Remove bolts from M10 at


Alternative user manuals
# User manual Category Download
1 American Power Conversion 100 User manual Power Supply 0
2 American Power Conversion 120 User manual Power Supply 0
3 American Power Conversion 110, 120, 230 User manual Power Supply 0
4 American Power Conversion 10000 VA User manual Power Supply 1
5 American Power Conversion 1000, 1100, 1400 User manual Power Supply 2
6 American Power Conversion 110Vac User manual Power Supply 0
7 American Power Conversion 1400XLT User manual Power Supply 0
8 American Power Conversion 1050 User manual Power Supply 0
9 American Power Conversion 10-40kW 208/480V User manual Power Supply 0
10 American Power Conversion 2200 VA User manual Power Supply 0
11 American Power Conversion 2200XLT User manual Power Supply 0
12 American Power Conversion 208/220 User manual Power Supply 0
13 American Power Conversion 20000 VA User manual Power Supply 3
14 American Power Conversion 2200VA 3U User manual Power Supply 0
15 American Power Conversion 230 VAC User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2