York PC9*DH user manual

User manual for the device York PC9*DH

Device: York PC9*DH
Category: Radio
Manufacturer: York
Size: 0.2 MB
Added : 9/27/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York PC9*DH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York PC9*DH.

For your convenience

If looking through the York PC9*DH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York PC9*DH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York PC9*DH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York PC9*DH User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York PC9*DH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York PC9*DH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

246815-YTG-D-0108
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
TECHN

Summary of the content on the page No. 2

246815-YTG-D-0108 22-3/4 7/8 A T-STAT WIRING 7/8” K.O. 7/8 T-STAT WIRING 7/8” K.O. HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” 13-7/8 HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” HORIZONTAL CONDENSATE 40 HORIZONTAL DRAIN OPENING 2” CONDENSATE DRAIN OPENING 1-3/4” JUNCTION BOX 29 29 HOLE 7/8” JUNCTION BOX 22-3/4 22-3/4 HOLE 7/8” GAS PIPE ENTRY 1-1/2” 21-5/8 21-1/4 GAS PIPE CONDENSATE DRAIN 18-1/2 18-1/2 ENTRY 1-1/2” HOLE 7/8” 11-3/4 SIDE PIPING HOLE 3-3/8” 9-1/8 7-1/2 CONDENSATE DRAIN 8-1/2 HOLE 7/

Summary of the content on the page No. 3

246815-YTG-D-0108 AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM PC9B12N060DH11 PC9B12N080DH11 JUMPER SETTINGS CFM CFM High Low High Low COOL Tap ADJ Tap 1330 900 1310 890 A B 1130 800 1100 740 B B 1220 850 1220 830 A A 1040 730 1000 670 B A 1120 770 1090 720 A C 920 650 900 610 C B 950 660 880 610 B C 740 540 680 510 D B 860 610 810 580 C A 690 540 630 500 D A 790 570 730 530 C C 630 530 590 500 D C PC9C16N080DH11 PC9C20N100DH11 PC9C16N100DH11 JUMPER SETTINGS CFM CFM High Low High Low

Summary of the content on the page No. 4

246815-YTG-D-0108 FILTER PERFORMANCE FILTER SIZES The airflow capacity data published in the “Blower Perfor- Cabinet Top Return mance” table listed above represents blower performance CFM Size Filter in WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- 1200 B (2) 14 x 20 ter being used or select an appropriate value from the “Filter 1600 C (2) 14 x 20 Performance” table shown. 2000 C (2) 14 x 20 NOTE: The filter pressure

Summary of the content on the page No. 5

246815-YTG-D-0108 For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available on-line at www.upgnet.com in the Product Catalog Section. AC 26A Two Stage Air Conditioner – Variable Speed Modulating Furnace ID MODELS PC9 FC9C FL9C THERMOSTAT THERMOSTAT VARIABLE SPEED TWO STAGE *DN22U00124 *PP32U70124 MODULATING AIR FURNACE CONDITIONER VARIABLE SPEED 1 MODULATING FURNACE CONTROL C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Vo

Summary of the content on the page No. 6

246815-YTG-D-0108 AC 26B Two Stage Air Conditioner – Variable Speed Modulating Furnace ID MODELS PC9 FC9C FL9C THERMOSTAT THERMOSTAT VARIABLE SPEED TWO STAGE *DN22C00124 *DP22U70124 MODULATING AIR FURNACE CONDITIONER VARIABLE SPEED 1 MODULATING FURNACE CONTROL C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Y Y1 Y1 Y1 First Stage Compressor First Stage Compressor Single Stage Compressor First Stage Compressor R R R R 24 – Volt Hot 24 – Volt Hot 24 – Volt Hot 24 – Vol

Summary of the content on the page No. 7

246815-YTG-D-0108 AC 26C Two Stage Air Conditioner – Variable Speed Modulating Furnace ID MODELS PC9 FC9C FL9C THERMOSTAT VARIABLE SPEED TWO STAGE *PP32U71124 MODULATING AIR *PP32U72124 FURNACE CONDITIONER VARIABLE SPEED 1 MODULATING FURNACE CONTROL C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common Y1 Y1 Y1 First Stage Compressor Single Stage Compressor First Stage Compressor R R R 24 – Volt Hot 24 – Volt Hot 24 – Volt Hot G G Comfort Alert Interface Fan Fan (two pin connector) E/W1 W Fi

Summary of the content on the page No. 8

246815-YTG-D-0108 HP 28A Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) ID MODELS OD MODELS PC9 YZE FC9C YZH FL9C H*5 THERMOSTAT H*8 VARIABLE SPEED TWO STAGE *PP32U71124 MODULATING HEAT PUMP *PP32U72124 FURNACE VARIABLE SPEED 2 YORKGUARD VI 1 MODULATING CONTROL FURNACE CONTROL C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common Y1 Y1 Y1 First Stage Compressor Single Stage Compressor Single Stage Compressor R R R 24 – Volt Hot 24 – Volt Hot 24 –

Summary of the content on the page No. 9

246815-YTG-D-0108 HP 28C Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) ID MODELS OD MODELS PC9 YZE FC9C YZH FL9C H*5 THERMOSTAT THERMOSTAT H*8 VARIABLE SPEED *DN22H00124 TWO STAGE *PP32U70124 MODULATING *DP22U70124 HEAT PUMP FURNACE VARIABLE SPEED 2 YORKGUARD VI 1 MODULATING CONTROL FURNACE CONTROL C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Y Y1 Y1 Y1 First Stage Compressor First Stage Compressor Single Stage Compressor S

Summary of the content on the page No. 10

246815-YTG-D-0108 COMBUSTIBLE FLOOR BASE - ACCESSORIES 1CB0317 - 17 1/2” Cabinet PROPANE (LP) CONVERSION KIT - 1CB0321 - 21” Cabinet 1NP0680 - All units 1CB0324 - 24-1/2” Cabinet This accessory conversion kit may be used to convert natural COIL TRANSITION - gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. 1TK0917 - 17 1/2” Cabinet 1TK0921 - 21” Cabinet CONCENTRIC VENT TERMINATION - 1TK0924 - 24-1/2” Cabinet 1CT0302 (2") Required

Summary of the content on the page No. 11

246815-YTG-D-0108 NOTES Unitary Products Group 11

Summary of the content on the page No. 12

NOTES Subject to change without notice. Printed in U.S.A. 246815-YTG-D-0108 Copyright © by Unitary Products Group. 2008. All rights reserved. Supersedes: 246815-YTG-C-0606 Unitary 5005 Norman Products York OK Group Drive 73069


Alternative user manuals
# User manual Category Download
1 Edelbrock 1799 User manual Radio 1
2 Sony ICF-9740W User manual Radio 69
3 Sony ICF-M55 User manual Radio 97
4 Sony ICF-790 User manual Radio 17
5 Sony ICF-M770SL User manual Radio 219
6 Sony ICF-M770S User manual Radio 127
7 Sony ICF-790S User manual Radio 16
8 Sony ICF-M33RDS User manual Radio 130
9 Sony HK-PSU04 User manual Radio 1
10 Sony ICF-S22 User manual Radio 10
11 Sony MKE-9020M User manual Radio 1
12 Sony ICF-SW35 User manual Radio 417
13 Sony MVE-8000A User manual Radio 1
14 Sony MVE-9000-C User manual Radio 4
15 Sony MKE-9040M User manual Radio 3