Fujitsu PRIMERGY BX600 S3 user manual

User manual for the device Fujitsu PRIMERGY BX600 S3

Device: Fujitsu PRIMERGY BX600 S3
Category: Server
Manufacturer: Fujitsu
Size: 4.55 MB
Added : 11/5/2013
Number of pages: 164
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu PRIMERGY BX600 S3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu PRIMERGY BX600 S3.

For your convenience

If looking through the Fujitsu PRIMERGY BX600 S3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu PRIMERGY BX600 S3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu PRIMERGY BX600 S3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu PRIMERGY BX600 S3 User manual - Online PDF
Advertisement
« Page 1 of 164 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu PRIMERGY BX600 S3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu PRIMERGY BX600 S3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PRIMERGY BX600 S3
Basic Unit
Operating Manual
Edition January 2009

Summary of the content on the page No. 2

Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which compl

Summary of the content on the page No. 3

Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.1 Overview of the Documentation . . . . . . . . . . . . . . . . . 8 1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.3 Notational Conventions . . . . . . . . . . . . . . . . . . . . 15 1.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . 16 2 Overview:

Summary of the content on the page No. 4

Contents 5 Preparation for Use and Operation . . . . . . . . . . . . . . . 49 5.1 Operating and Indicator Elements of the Basic Unit . . . . . 50 5.1.1 The Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.1.2 The Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 5.2 Switching the Basic Unit ON/OFF . . . . . . . . . . . . . . . 53 5.3 Management Blade Configuration . .

Summary of the content on the page No. 5

Contents 9 Fibre Channel I/O Blades . . . . . . . . . . . . . . . . . . . 101 9.1 4/4 Gbit Fibre Channel Switch Blade (Brocade SilkWorm 4016 4D) . . . . . . . . . . . . . . . . . 102 9.2 2/4 Gbit Fibre Channel Switch Blade (Brocade SilkWorm 4016) . . . . . . . . . . . . . . . . . . . 104 9.3 2 Gbit Fibre Channel Pass-Thru Blade . . . . . . . . . . . . 105 9.4 4 Gbit Fibre Channel Pass-Thru Blade . . . . . . . . . . .

Summary of the content on the page No. 6

Contents 13.1.2 Replacing a Fan in the Unit . . . . . . . . . . . . . . . . . . . 143 14 Troubleshooting and Tips . . . . . . . . . . . . . . . . . . . 145 14.1 System Power LED Remains Unlit . . . . . . . . . . . . . . 145 14.2 Front or Rear Identify/Fault LED Blinks Amber . . . . . . . 146 14.3 System Switches Itself OFF . . . . . . . . . . . . . . . . . . 147 14.4 Screen Remains Dark . . . . . . . . . . . . .

Summary of the content on the page No. 7

1 Preface The PRIMERGY BX600 S3 Blade Server System represents a highly compact, power-saving and scalable servers for integration in 19-inch rack systems. Figure 1: PRIMERGY BX600 S3 Basic Unit The PRIMERGY BX600 S3 basic unit occupies seven height units in the rack and can accommodate up to ten server blades of different models and configu- rations. As economical, ultra-compact systems, the server blades with up to eight CPUs are ideal for use by company data centers and Internet service pr

Summary of the content on the page No. 8

Overview of the Documentation Preface Security functions in the BIOS Setup protect the data on the server blades against manipulation. Additional security is provided by the lockable rack door. 1.1 Overview of the Documentation I PRIMERGY manuals are available in PDF format on the PRIMERGY ServerView Suite DVD 2. The PRIMERGY ServerView Suite DVD 2 is part of the PRIMERGY ServerView Suite supplied with every server. If you no longer have the ServerView Suite DVDs, you can obtain the relevant

Summary of the content on the page No. 9

Preface Overview of the Documentation – “Returning used devices” manual (PDF file available on the ServerBooks DVD supplied) – “Helpdesk” (leaflet with worldwide helpdesk telephone numbers) – “BIOS Setup” (PDF file available on the ServerBooks DVD supplied) – „PRIMERGY BX Blade Server Systems: RemoteView Management Blade - User Interface Description“ (PDF file available on the ServerBooks DVD supplied) – „PRIMERGY BX Blade Server Systems: LAN Switch Blade - User Interface Description“ (PDF f

Summary of the content on the page No. 10

Features Preface 1.2 Features The PRIMERGY BX600 S3 basic unit provides a high-level infrastructure for the installed server blades. Server Capacity The PRIMERGY BX600 S3 basic unit provides slots for up to ten hot-pluggable server blades. For details of the performance features of the different server blade models, see the relevant operating manuals listed under “Related Publi- cations” on page 157. Communication Interfaces The PRIMERGY BX600 S3 basic unit has four slots on the back for ins

Summary of the content on the page No. 11

Preface Features Gbit Ethernet LAN Switch Blade (SB9F) 12x1 Gbit – 30 internal 1Gbit ports to the server blades – 12 external 1Gbit ports (RJ45) I This switch blade can only be installed in slots NET1 and NET2. The number of available ports depends on the types of server blades installed, see page 80. 10 Gbit switch blade 10/2 – 10 internal 10 Gbit/s ports to the server blades – 2 external 10 Gbit/s ports with optional X2 transceiver modules for Fiber-Optical or CX4 copper cable I This switc

Summary of the content on the page No. 12

Features Preface 4/4Gbit Fibre Channel Switch Blade Brocade SilkWorm 4016 4D – 10 internal 4Gbit/s ports to the server blades – 6 external 4Gbit/s ports via a GBIC/SFP module I In addition to the 16-port variant, a model with 12 dynamically assignable ports is available (e.g. 4 external and 8 internal ports). You can upgrade this model to a 16-port variant later. 4Gbit Fibre Channel Pass-Thru Blade – 10 internal 4Gbit/s ports to the server blades – 10 external 4Gbit/s ports via a GBIC/SFP mo

Summary of the content on the page No. 13

Preface Features Power Supply Up to four hot-swappable power supply units which adjust automatically to any power voltage in the range 200 - 240 V in a 2+2 redundant power supply config- uration ensure enough power for the system. If one of these units fails, the others ensure that operation continues unimpaired. The defective power supply unit can be replaced during operation (hot-swap). Ventilation The system is kept cool by three fans in each power supply unit and four single fans, with t

Summary of the content on the page No. 14

Features Preface ● Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event of memory modules or processors failing ● Power monitoring ● End-of-life monitoring of the fans with timely notification before a failure ● Watchdog timer for operating system monitoring and application monitoring with ASR&R Deployment software makes installing multiple servers fast and easy. For further information, see the corresponding documentation (see “Related Publications” on page 1

Summary of the content on the page No. 15

Preface Notational Conventions 1.3 Notational Conventions The following notational conventions are used in this manual: Italics indicate commands, menu items or software programs. “Quotation marks” indicate names of chapters and terms that should be emphasized. Ê Text which follows this symbol describes activities that must be performed in the order given. V CAUTION! Pay particular attention to text marked with this symbol. Failure to observe this warning may endanger your life, damage the s

Summary of the content on the page No. 16

Technical Data Preface 1.4 Technical Data Electrical Data (single power supply unit) Rated voltage range 200 - 240 V Rated frequency 50 Hz - 60 Hz Max. rated current 230V / 11,6 A Max. active power 230 V / 2650 W Max. apparent power 2680 VA (230V) Thermal dissipation 2050 kJ/h Protection class I Electrical Data (basic unit without server blades) Power consumption 360 W Thermal dissipation 1300 kJ/h Compliance Standards Product safety and ergonomics IEC 60950 / EN 60950 UL 1950 3rd Edition, CSA

Summary of the content on the page No. 17

Preface Technical Data Certification Product safety Global CB Europe ENEC Germany GS USA/Canada CSA / CSA US C Japan VCCI Australia C-tic Taiwan BSMI (CNS 13438) Mechanical Values Width 446 mm Installation depth 740 mm Height 307 mm oder 7 HE Weight max. 131,5 kg (depending on the configuration) Environmental Conditions Environment class 3K2 DIN IEC 721 section 3-3 Environment class 2K2 DIN IEC 721section 3-2 Temperature: Operation (3K2) 5 ºC .... 35 ºC Transport (2K2) -20 °C .... 60 °C Relati

Summary of the content on the page No. 18

Technical Data Preface Noise Level Sound power level L 8,7 B (operating) WAd Sound pressure level L 70 dB (operating) pAm measured according to ISO 7779 and declared according to ISO 9296 18 Operating Manual BX600 S3 © cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: H:\April\PRIMERGY_Rebranding\von Walter\bx600_s3_ba\BX600S3_en\blade-us.k01

Summary of the content on the page No. 19

2 Overview: Installation Steps In this chapter you will find an overview of the steps necessary to install your BX600 S3 basic unit. Links guide you to sections where you can find more detailed information on the individual steps. Ê Before you begin, please read the chapter “Important Notes” beginning on page 21, especially the section “Notes on Safety”. Ê Unpack the system, check the contents of the package for visible transport damage, and check whether the delivery matches the details in

Summary of the content on the page No. 20

Overview: Installation Steps – Remote installation with ServerView Installation Manager This installation method is recommended if a LAN connection and a DHCP server are available but the requirements for cloning are not satis- fied. – Local installation with or without ServerView Installation Manager Since the local installation is the least convenient installation method, it is only recommended if the requirements for remote installation or cloning are not satisfied. If you wish to install


Alternative user manuals
# User manual Category Download
1 Fujitsu BX900 S1 User manual Server 23
2 Fujitsu 2000 User manual Server 1
3 Fujitsu CM71-00101-5E User manual Server 1
4 Fujitsu 5.0L10 User manual Server 1
5 Fujitsu 2000 SERIES User manual Server 1
6 Fujitsu Cloud Edition V3.1.0 User manual Server 0
7 Fujitsu C122-E180-01EN User manual Server 0
8 Fujitsu C120-E361-04EN User manual Server 2
9 Fujitsu M10-4S User manual Server 0
10 Fujitsu M10 User manual Server 1
11 Fujitsu M10-4 User manual Server 0
12 Fujitsu C122-H007-01EN User manual Server 0
13 Fujitsu J2X0-2273-01EN User manual Server 0
14 Fujitsu M8000 User manual Server 0
15 Fujitsu RX300 S2 User manual Server 25
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9