Dell POWEREDGE CLUSTER SL200 user manual

User manual for the device Dell POWEREDGE CLUSTER SL200

Device: Dell POWEREDGE CLUSTER SL200
Category: Server
Manufacturer: Dell
Size: 0.1 MB
Added : 9/8/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dell POWEREDGE CLUSTER SL200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dell POWEREDGE CLUSTER SL200.

For your convenience

If looking through the Dell POWEREDGE CLUSTER SL200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dell POWEREDGE CLUSTER SL200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dell POWEREDGE CLUSTER SL200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dell POWEREDGE CLUSTER SL200 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dell POWEREDGE CLUSTER SL200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dell POWEREDGE CLUSTER SL200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Dell™ PowerEdge™ Cluster SE100, SE200, and SL200
PLATFORM GUIDE

www.dell.com
support.dell.com

Summary of the content on the page No. 2

Notes, Notices, Cautions, and Warnings Throughout this guide, blocks of text may be accompanied by an icon and printed in bold type or in italic type. These blocks are notes, notices, cautions, and warnings, and they are used as follows: NOTE: A NOTE indicates important information that helps you make better use of your computer system. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potenti

Summary of the content on the page No. 3

Contents PowerEdge Cluster SE100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Windows 2000 Advanced Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Windows NT 4.0 Server, Enterprise Edition. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Windows NT 4.0 Service Pack Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Adding Peripherals Required for PowerEdge 2300, 4300, or 4350 . . . . .

Summary of the content on the page No. 4

iv

Summary of the content on the page No. 5

Dell™ PowerEdge™ Cluster SE100, SE200, and SL200 Platform Guide ® ® This guide provides the latest information on using Microsoft Windows NT Server ® 4.0, Enterprise Edition operating system and Windows 2000 Advanced Server oper- ating system for the following Dell PowerEdge Cluster products and components: • Dell PowerEdge Cluster SE100 — Servers: PowerEdge 2300, 4300, 4350, 6300, and 6350 — Storage: PowerVault™ 200S, 201S, 210S, and 211S — Cluster interconnect: Fast Ethernet • Dell PowerEdge

Summary of the content on the page No. 6

PowerEdge Cluster SE100 The PowerEdge Cluster SE100 supports clustering with Windows NT Server 4.0, Enterprise Edition or Windows 2000 Advanced Server. See the following sections for information on supported configurations and service packs (SPs) for your Windows operating system. Windows 2000 Advanced Server Installation instructions for hardware configurations using Windows 2000 Advanced Server can be found in the Dell PowerEdge Cluster SE100, SE200, and SL200 Installa- tion and Troublesho

Summary of the content on the page No. 7

Windows NT 4.0 Service Pack Support Windows NT SP 6.0a or later is recommended for PowerEdge Cluster SE100 systems. NOTE: Both nodes must be configured with similar drivers (network interface control- lers [NIC], redundant array of independent disks [RAID] controller, and so on), utilities (Dell OpenManage™ suite, PowerConsole, and so on), firmware (PowerEdge Expand- able RAID Controller 2/SC [PERC 2/SC]), and the latest basic input/output system [BIOS] for each system. When planning for and

Summary of the content on the page No. 8

Adding Peripherals Required for PowerEdge 6300 or 6350 WARNING: Hardware installation should be performed only by trained service technicians. Before working inside the computer system, see the safety instructions in your PowerEdge system documentation to avoid a situation that could cause serious injury or death. The following list provides PCI slot assignment information for buses, RAID control- lers, NICs, and a DRAC 2. • PCI buses — PCI bus 1: PCI slots 1 through 3 are 32-bit, 33-megahe

Summary of the content on the page No. 9

Your PowerEdge Cluster SE200 and SL200 system supports the following PowerEdge servers as cluster nodes in homogeneous pairs (same server) with Windows 2000 Advanced Server: • PowerEdge 2400 • PowerEdge 2450 • PowerEdge 4400 • PowerEdge 6400 • PowerEdge 6450 • PowerEdge 8450 NOTE: Heterogeneous server clusters (mixed server models) are not supported with PowerEdge Cluster SE200 and SL200 configurations running Windows 2000 Advanced Server. Windows NT Server 4.0, Enterprise Edition Your Power

Summary of the content on the page No. 10

Windows NT 4.0 Service Pack Support Windows NT SP 6.0a or later is recommended for PowerEdge Cluster SE200 and SL200 systems. NOTE: Both nodes must be configured with similar drivers (NIC, RAID controller, and so on), utilities (Dell OpenManage suite, PowerConsole, and so on), firmware (PERC 2/DC), and the latest BIOS for each system. When planning for and testing your heterogeneous configurations, ensure that ade- quate resources are available on the server node to run all of the application

Summary of the content on the page No. 11

• NICs — You can install NICs in any available PCI slot. • DRAC 2 — If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 6. NOTE: To make sure that the SCSI or RAID controller attached to the boot drives initializes first, you may have to change the scan order of the PCI bus, if the BIOS sup- ports this option, or change the order of the RAID, NIC, and DRAC 2. Performing these tasks ensures that Windows numbers the boot drives in the proper sequence. Ad

Summary of the content on the page No. 12

Adding Peripherals Required for PowerEdge 4400 Cluster Nodes WARNING: Hardware installation should be performed only by trained service technicians. Before working inside the computer system, see the safety instructions in your PowerEdge system documentation to avoid a situation that could cause serious injury or death. The following list provides PCI slot assignment information for the system’s PCI buses, RAID controllers, NICs, and DRAC 2. • PCI buses — PCI bus 1: PCI slots 1 and 2 are 6

Summary of the content on the page No. 13

• PCI buses — PCI bus 1: PCI slot 1 is 32-bit, 33-MHz — PCI bus 2: PCI slots 2 through 5 are 64-bit, 33-MHz — PCI bus 3: PCI slots 6 and 7 are 64-bit, 33/66-MHz • RAID controllers — RAID controllers can be installed in any available 32-bit, 33-MHz or 64-bit, 33-MHz PCI slot. — If you use multiple RAID controllers and there are available PCI slots, Dell recommends installing the RAID controllers on separate PCI buses to bal- ance the load on the system. NOTICE: The PERC 2/DC is keyed to prevent

Summary of the content on the page No. 14

• RAID controllers — Install the RAID controller for the server’s internal drives in PCI slot 1. — Install additional RAID controllers in any available 64-bit, 33-MHz or 32-bit, 33-MHz PCI slot. — If you use multiple RAID controllers and there are available slots, Dell recom- mends installing the RAID controllers on separate 64-bit PCI buses to balance the load on the system. NOTICE: The PERC 2/DC is keyed to prevent installation in a 64-bit 33/ 66 MHz PCI slot. NOTE: The PERC 2/DC comes fitte

Summary of the content on the page No. 15

• Storage array description for each storage array • Service tag information for each cluster component • Connectivity information to indicate the SCSI connector (A or B) on each shared storage system that connects to the RAID controller channel (A or B) on each shared storage system; see the PowerEdge Cluster Configuration Matrix for spe- cific instructions • Each cluster node’s PCI slot number, a description of each slot, the adapters installed in each slot, and a usage description for each

Summary of the content on the page No. 16

PowerEdge Cluster SE100 Configuration Matrix Cluster Type PowerEdge Cluster SE100 Cluster Name Installer Date Installed Applications Location Notes Node PowerEdge Server Model Windows NT Name Node 1 Node 2 Storage Array Description (Drive letters, RAID types, applications/data installed) Storage 1 Storage 2 Component: Node 1 Node 2 Storage 1 1 Storage 2 2 Service Tag System Storage 1 Storage 2 Node 1, controller 1 Node 2, controller 1 Node 1, controller 2 Node 2, controller 2 PCI Slot PCI Slot

Summary of the content on the page No. 17

PowerEdge Cluster SE200/SL200 Configuration Matrix Cluster Type PowerEdge Cluster SE200 or SL200 Cluster Name Installer Date Installed Applications Location Notes Node PowerEdge Server Model Windows NT Name Node 1 Node 2 Storage Array Description (Drive letters, RAID types, applications/data installed) Storage 1 Storage 2 Storage 3 Storage 4 Node 1 Node 2 Storage 1 Storage 2 Storage 3 Storage 4 Component: Service Tag System Storage 1 Storage 2 Storage 3 Storage 4 Node 1, controller 1 Node 2, co

Summary of the content on the page No. 18

14 Dell PowerEdge Cluster SE100, SE200, and SL200 Platform Guide


Alternative user manuals
# User manual Category Download
1 Dell 2450 User manual Server 5
2 Dell 750N. 755N User manual Server 1
3 Dell C6220 User manual Server 5
4 Dell 35XX User manual Server 1
5 Dell C5220 User manual Server 3
6 Dell 350 User manual Server 2
7 Dell 530F User manual Server 2
8 Dell 2950 User manual Server 14
9 Dell E600I User manual Server 0
10 Dell CX4 User manual Server 10
11 Dell E19S User manual Server 26
12 Dell R200 User manual Server 22
13 Dell MD3620F User manual Server 1
14 Dell MD3600F User manual Server 3
15 Dell R420 User manual Server 5
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9