Anritsu S251C user manual

User manual for the device Anritsu S251C

Device: Anritsu S251C
Category: Stereo System
Manufacturer: Anritsu
Size: 1.06 MB
Added : 3/4/2014
Number of pages: 81
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Anritsu S251C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Anritsu S251C.

For your convenience

If looking through the Anritsu S251C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Anritsu S251C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Anritsu S251C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Anritsu S251C User manual - Online PDF
Advertisement
« Page 1 of 81 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Anritsu S251C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Anritsu S251C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Site Master
Model S251C
Antenna and
Cable Analyzer
User's Guide
Hand-Held Tester for Transmission Lines
and other RF Components
Color Front Cover only P/N: 00986-00045

Summary of the content on the page No. 2

Summary of the content on the page No. 3

WARRANTY The Anritsu product(s) listed on the title page is (are) warranted against defects in materials and workmanship for one year from the date of shipment. Anritsu's obligation covers repairing or replacing products which prove to be defec- tive during the warranty period. Buyers shall prepay transportation charges for equipment returned to Anritsu for warranty repairs. Obligation is limited to the origi- nal purchaser. Anritsu is not liable for consequential damages. LIMITATION OF WARRANTY

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Table of Contents Chapter 1 - General Information Introduction ..................................1-1 Description...................................1-1 Standard Accessories .............................1-1 Options.....................................1-2 Optional Accessories..............................1-2 Performance Specifications ..........................1-3 Preventive Maintenance............................1-6 ESD Precautions................................1-6 Annual Verification ...........

Summary of the content on the page No. 6

Saving a Setup....................................3-5 Recalling a Setup...................................3-5 Save and Recall a Display...........................3-5 Saving a Display...................................3-5 Recalling a Display .................................3-6 Set the Distance and Cable Type .......................3-7 Changing the Units ..............................3-7 Changing the Display Language........................3-7 Printing.....................................3-8 Prin

Summary of the content on the page No. 7

Appendix A - Reference Data Coaxial Cable Technical Data.........................A-1 Appendix B - Windowing Introduction ..................................B-1 Examples ...................................B-1 iii/iv

Summary of the content on the page No. 8

Chapter 1 General Information Introduction This chapter provides a description, performance specifications, optional accessories, pre- ventive maintenance, and calibration requirements for the Site Master model S251C. 1 Throughout this manual, the term Site Master will refer to the S251C. Model Frequency Range Ports S251C 625 to 2500 MHz 2 Description The Site Master is a hand held SWR/RL (standing wave ratio/return loss), transmission gain/loss and Distance-To-Fault (DTF) measurement instrument

Summary of the content on the page No. 9

Chapter 1 General Information The following items are supplied with the basic hardware.  Soft Carrying Case  AC-DC Adapter  Automotive Cigarette Lighter 12 Volt DC Adapter,  CDROM disk containing the Software Tools program. This program contains Fault Lo- cation (DTF) and Smith Chart functions  Serial Interface Cable (null modem type)  One year Warranty (includes battery, firmware, and software)  User's Guide Options  Option 5 — Add RF Wattmeter Power Monitor  Option 10A Add Bias Tee O

Summary of the content on the page No. 10

Chapter 1 General Information  Armored Test Port Extension Cable, 1.5 meter, N (m) to N (m), Part No. 15NN50-1.5C  Armored Test Port Extension Cable, 3.0 meter, N (m) to N (m), Part No. 15NN50-3.0C  Armored Test Port Extension Cable, 5.0 meter, N (m) to N (m), Part No. 15NN50-5.0C  Armored Test Port Extension Cable, 1.5 meter, N (m) to 7/16 DIN (f), Part No. 15NDF50-1.5C  Armored Test Port Extension Cable, 1.5 meter, N (m) to 7/16 DIN (m), Part No. 15ND50-1.5C  RF Detector, 1 to 3000 MHz,

Summary of the content on the page No. 11

Chapter 1 General Information Table 1-1. Performance Specifications (1 of 2) Specifications are valid when the unit is calibrated at ambient temperature after a 5 minute warmup. Description Value Site Master: Frequency Range: S251C 625 to 2500 MHz Frequency Accuracy (RF Source Mode): 75 parts per million @ 25°C* Frequency Resolution: 10 kHz SWR: Range 1.00 to 65.00 Resolution 0.01 Return Loss: Range 0.00 to 54.00 dB Resolution 0.01 dB **Distance-To-Fault (DTF): Range (in meters) 0 to (Resolutio

Summary of the content on the page No. 12

Chapter 1 General Information Table 1-2. Performance Specifications (2 of 2) Cable Insertion Loss: Range 0.00 to 54.00 dB Resolution 0.01 dB Bias Tee input voltage: 12.5 to 15.0 Vdc output current: 270 ma maximum surge, 25 ms 240 ma maximum steady General Internal Memory: Trace Memory 200 maximum Instrument config. 10 setup locations with associated calibration RS-232 9 pin D-sub, three wire serial Electromagnetic Compatibility Meets European Community requirements for CE marking Power Supply: E

Summary of the content on the page No. 13

Chapter 1 General Information Preventive Maintenance Site Master preventive maintenance consists of cleaning the unit and inspecting and clean- ing the RF connectors on the instrument and all accessories. Clean the Site Master with a soft, lint-free cloth dampened with water or water and a mild cleaning solution. CAUTION: To avoid damaging the display or case, do not use solvents or abra- sive cleaners. Clean the RF connectors and center pins with a cotton swab dampened with denatured alco- hol.

Summary of the content on the page No. 14

Chapter 1 General Information Annual Verification Anritsu recommends an annual calibration and performance verification of the Site Master and the OSL calibration components by local Anritsu service centers. Anritsu service cen- ters are listed in Table 1-2 on the following page. The Site Master itself is self-calibrating, meaning that there are no field-adjustable compo- nents. However, the OSL calibration components are crucial to the integrity of the calibra- tion and therefore, must be verif

Summary of the content on the page No. 15

Chapter 1 General Information Table 1-2. Anritsu Service Centers UNITED STATES GERMANY SOUTH AFRICA ANRITSU COMPANY ANRITSU GmbH ETESCSA 685 Jarvis Drive Grafenberger Allee 54-56 12 Surrey Square Office Park Morgan Hill, CA 95037-2809 D-40237 Dusseldorf 330 Surrey Avenue Telephone: (408) 776-8300 Germany Ferndale, Randburt, 2194 FAX: 408-776-1744 Telephone: 0211-968550 South Africa FAX: 0211-9685555 Telephone: 011-27-11-787-7200 ANRITSU COMPANY Fax: 011-27-11-787-0446 10 NewMaple Ave., Suite 305

Summary of the content on the page No. 16

Chapter 2 Functions and Operations Introduction This chapter provides a brief overview of the Site Master functions and operations, provid- ing the user with a starting point for making basic measurements. For more detailed infor- mation, refer to Chapter 4, Measurements and Chapter 5, Software Tools. The Site Master is designed specifically for field environments and applications requiring mobility. As such, it is a lightweight, handheld, battery operated unit which can be easily carried to any

Summary of the content on the page No. 17

Chapter 2 Functions and Operations Front Panel Overview The Site Master menu-driven user interface is easy to use and requires little training. Hard keys on the front panel are used to initiate function-specific menus. There are four function hard keys located below the display, Mode, Frequency/Distance, Amplitude and Sweep. There are seventeen keypad hard keys located to the right of the display. Twelve of the key- pad hard keys are dual purpose, depending on the current mode of operation. The

Summary of the content on the page No. 18

Chapter 2 Functions and Operations Function Hard Keys MODE Opens the mode selection box (below). Use the Up/Down arrow key to select a mode. Press the ENTER key to implement. MEASUREMENT MODE FREQ - SWR RETURN LOSS CABLE LOSS - ONE PORT INSERTION LOSS (+6 dBm) INSERTION GAIN (–30 dBm) DTF - SWR RETURN LOSS POWER MONITOR RF SOURCE Figure 2-2. Mode Selection Box FREQ/DIST Displays the Frequency or Distance to Fault softkey menus depending on the measurement mode. AMPLITUDE Displays the amplitude s

Summary of the content on the page No. 19

Chapter 2 Functions and Operations Keypad Hard Keys This section contains an alphabetical listing of the Site Master front panel keypad controls along with a brief description of each. Where necessary, more detailed descriptions of the major function keys follow. The following keypad hard key functions are printed in black on the keypad keys. 0-9 These keys are used to enter numerical data as required to setup or per- form measurements. The plus/minus key is used to enter positive or negative va

Summary of the content on the page No. 20

Chapter 2 Functions and Operations The following keypad hard key functions are printed in blue on the keypad keys. Turns the liquid crystal display (LCD) back-lighting ON or OFF. (Leaving back lighting off conserves battery power.) LCD Contrast adjust. Use the Up/Down arrow key and ENTER to adjust the display contrast. AUTO Automatically scales the display for optimum resolution. SCALE LIMIT Displays the limit menu of the current operating mode. MARKER Displays the marker menu of the current ope


Alternative user manuals
# User manual Category Download
1 Anritsu S114C User manual Stereo System 3
2 Anritsu S331C User manual Stereo System 74
3 Anritsu S251B User manual Stereo System 15
4 Anritsu S332C User manual Stereo System 15
5 Anritsu S113C User manual Stereo System 2
6 Sony 3-287-077-14(2) User manual Stereo System 128
7 Sony 3-300-703-11(2) User manual Stereo System 16
8 Sony 3-452-364-11(1) User manual Stereo System 6
9 Sony 3-294-663-11(2) User manual Stereo System 7
10 Sony 3-CD DOUBL MHC-RG290 User manual Stereo System 179
11 Sony 4-183-777-12(1) User manual Stereo System 9
12 Sony 3-293-639-11(1) User manual Stereo System 4
13 Sony 4-199-697-12(1) User manual Stereo System 3
14 Sony 3-097-196-14(1) User manual Stereo System 5
15 Sony 3-097-194-15(1) User manual Stereo System 2