Goodman Mfg 000 BTUH + 115 Volt user manual

User manual for the device Goodman Mfg 000 BTUH + 115 Volt

Device: Goodman Mfg 000 BTUH + 115 Volt
Category: Air Conditioner
Manufacturer: Goodman Mfg
Size: 0.94 MB
Added : 7/1/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg 000 BTUH + 115 Volt. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg 000 BTUH + 115 Volt.

For your convenience

If looking through the Goodman Mfg 000 BTUH + 115 Volt user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg 000 BTUH + 115 Volt on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg 000 BTUH + 115 Volt to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg 000 BTUH + 115 Volt User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg 000 BTUH + 115 Volt but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg 000 BTUH + 115 Volt. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION & OPERATIONS MANUAL
SPLIT TYPE ROOM AIR CONDITIONER AND HEAT PUMP MODELS
MSC/MSH 9,000 & 12,000 BTUH • 115 VOLT
O
Important Safety Instructions
The following symbols and labels are used throughout this
To prevent the risk of property damage, personal injury, or
manual to indicate immediate or potential safety hazards. It is
death, do not store combustible materials or use gasoline
the owner’s and installer’s responsibility to read and comply
or other flammable liquids or vapors in

Summary of the content on the page No. 2

CONTENTS • Be sure that placement of the unit allows adequate con- densate drainage. Important Safety Instructions .............................................. 1 Shipping Inspection ............................................................ 1 • Do not install near a doorway. Codes & Regulations ......................................................... 2 • Ensure that the spaces indicated by the arrows is from Installation Considerations ................................................. 2 the

Summary of the content on the page No. 3

• Select a location where noise, vibration and hot dis- charged air will not be an issue. • Do not install where high frequency equipment is used (wireless equipment, welding machine, medical facility) as it may interfere with the unit’s operation. Rooftop Installations If it is necessary to install the outdoor unit on a roof structure, ensure the roof structure can support the weight and that proper consideration is given to the weather-tight integrity of the roof. Since the unit can vibrate du

Summary of the content on the page No. 4

NOTE: Install the mounting bracket and drill the holes in the Wall wall according to the wall structure and the correspond- Outdoor ing mounting points on the mounting bracket. (The Indoor mounting brackets vary according to the model.) Incorrect orientation Correct orientation of Installation Plate of Installation Plate Figure 6 Do NOT install drain hose as shown in Figure 7. Figure 4 4. Determine the hole positions according to the diagram detailed in Figures 5A & 5B. Drill one (1) 2.5” ho

Summary of the content on the page No. 5

Indoor Unit Installation 9. Pass the piping through the hole in the wall. Do not allow piping to hold indoor unit away 10. Place the upper claw on the back of the indoor unit on from the wall. Never intertwine power wiring and other wiring. the upper hook of the installation plate. Move the indoor unit from side to side to ensure it is securely mounted. (See Figure 10 ). Outdoor Unit Installation NOTE: By placing cushioning material between the in- door unit and the wall, placement of piping is

Summary of the content on the page No. 6

1 Figure 14A (Figure 15A) (Figure 15B) 2 Figure 14B MS* 9 & MS*12 Correct alignment Mounting Dimensions Outdoor Unit Dimensions Inches/mm (L1xHxW1) L2 (mm) W2 (mm) 30" x 23" x 11" 21" 11 1/2" 760 x 590 x 285 530 290 Drain joint installation Incorrect alignment NOTE: Drain joints differ slightly according to the different outdoor units. Inspect your unit and use the installation in- Figure 16 structions for your specific unit. For drain joints with seals (Figure 15A): Refrigerant Pipe Connectio

Summary of the content on the page No. 7

2. Insert tube in flare tool to measurement “A” in chart. Tightening Additional Outdoor Flare tubing as shown in Figure 19. Make sure flare is Torque Tightening Diameter (mm) (N. cm) Torque (N. cm) free of burrs and completely formed to make a leak proof joint. 1500 1600 1/4" ( Φ 6.35) (153kgf.cm) (163kgf.cm) NOTE: In order to avoid dropping burrs into the tubing, angle the end of the copper tube/pipe in a downward 2500 2500 3/8" ( Φ 9.52) (255kgf.cm) (265kgf.cm) direction as you remove the bu

Summary of the content on the page No. 8

IMPORTANT NOTES: • If there are safety issues concerning the power supply, the unit should not be connected until safety issues are resolved. • Ensure that the electrical power supply is sufficient to safely power and run the unit. • Power voltage should range for 90% - 110% of the rated voltage. • Main power switch and surge protector should be 1.5 Electrical box times the capacity of the maximum current of the unit cover and should be installed in the power circuit. Figure 22 • The unit is to

Summary of the content on the page No. 9

9. The means to disconnect from a power supply should be Terminals on the indoor unit L N S incorporated in the fixed wiring and have an air gap con- tact separation of at least 1/8” (3 mm) in each active (phase) conductor. L N S Leak Testing (Nitrogen or Nitrogen-Traced) Pressure test the system, using dry nitrogen and soapy water Model A to locate any leaks in the system. If you wish to use a leak detector, charge the system to 10 psi using the appropriate refriger

Summary of the content on the page No. 10

Use caution when handling the packed valve: • When relocating the unit to another place, perform the evacuation using a vacuum pump. • Open the valve stem unit it comes in contact against the stopper. Do not attempt to open further. • Refrigerant added to the unit must be in liquid form. (Does not apply to units using R-22.) Safe Refrigerant Handling C While these items will not cover every conceivable situation, they should serve as a useful guide. D WARNING B Refrigerants are heavier than ai

Summary of the content on the page No. 11

• Grasp the panel sides and lift up the panel to an angle Test Running where it remains fixed and a clicking sound is heard. After completing the gas leak check at the flare nut connec- tions and electrical safety check, perform the test operation. • Press the manual control button to select AUTO or COOL. The unit will operate under forced AUTO or COOL mode • Ensure all tubing and wiring have been properly con- (see User’s manual for more details). nected. • Make sure both the gas and liquid sid

Summary of the content on the page No. 12

Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com © 2011 Goodman Manufacturing Company, L.P. 12


Alternative user manuals
# User manual Category Download
1 Goodman Mfg ARPT User manual Air Conditioner 12
2 Goodman Mfg 13 SEER GPC13M User manual Air Conditioner 22
3 Goodman Mfg ADPF User manual Air Conditioner 4
4 Goodman Mfg 10.3 EER User manual Air Conditioner 7
5 Goodman Mfg AEPT User manual Air Conditioner 2
6 Goodman Mfg ARUF182416CA User manual Air Conditioner 37
7 Goodman Mfg A/GPG13 M User manual Air Conditioner 2
8 Goodman Mfg ARPF User manual Air Conditioner 6
9 Goodman Mfg 13 SEER GPC13H User manual Air Conditioner 4
10 Goodman Mfg ARUF172916CA User manual Air Conditioner 7
11 Goodman Mfg ARUF User manual Air Conditioner 11
12 Goodman Mfg ARUF303016CA User manual Air Conditioner 33
13 Goodman Mfg ARUF193116CA User manual Air Conditioner 10
14 Goodman Mfg ARUF364216CA User manual Air Conditioner 26
15 Goodman Mfg ARUF486016CA User manual Air Conditioner 46
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21