Emerson Process Management - Emerson Electric Co.53eA user manual

User manual for the device Emerson Process Management - Emerson Electric Co.53eA

Device: Emerson Process Management - Emerson Electric Co.53eA
Category: Stud Sensor
Manufacturer: Emerson Process Management
Size: 1.04 MB
Added : 8/28/2013
Number of pages: 116
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson Process Management - Emerson Electric Co.53eA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson Process Management - Emerson Electric Co.53eA.

For your convenience

If looking through the Emerson Process Management - Emerson Electric Co.53eA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson Process Management - Emerson Electric Co.53eA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson Process Management - Emerson Electric Co.53eA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson Process Management - Emerson Electric Co.53eA User manual - Online PDF
Advertisement
« Page 1 of 116 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson Process Management - Emerson Electric Co.53eA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson Process Management - Emerson Electric Co.53eA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
51-54eA/rev.J
May 2006
Model 54eA
®
Amperometric HART Analyzer/Controller

Summary of the content on the page No. 2

WARNING ESSENTIAL INSTRUCTIONS ELECTRICAL SHOCK HAZARD READ THIS PAGE BEFORE PROCEEDING! Making cable connections to and servicing this instru- ment require access to shock hazard level voltages Rosemount Analytical designs, manufactures, and tests its products to which can cause death or serious injury, therefore, meet many national and international standards. Because these instru- disconnect all hazardous voltage before accessing ments are sophisticated technical products, you must properly

Summary of the content on the page No. 3

Summary of the content on the page No. 4

MODEL 54eA TABLE OF CONTENTS MODEL 54eA ANALYZER/CONTROLLER TABLE OF CONTENTS Section Title Page 1.0 SPECIFICATIONS................................................................................................... 1 1.1 Features and Applications....................................................................................... 1 1.2 Specifications........................................................................................................... 2 1.3 Ordering Information............

Summary of the content on the page No. 5

MODEL 54eA TABLE OF CONTENTS TABLE OF CONTENTS (CONTINUED) Section Title Page 9.0 CALIBRATION - FREE CHLORINE (498 ACL-01) ................................................ 60 9.1 Introduction.............................................................................................................. 60 9.2 Zeroing the Sensor.............................

Summary of the content on the page No. 6

MODEL 54eA TABLE OF CONTENTS LIST OF FIGURES Section Title Page 2-1 Wall Mounting.......................................................................................................... 5 2-2 Pipe Mounting.......................................................................................................... 6 2-3 Pipe and Wall Mounting Dimensions....................................................................... 6 2-4 Panel Mounting.......................................................

Summary of the content on the page No. 7

MODEL 54eA SECTION 1.0 SPECIFICATIONS SECTION 1.0 SPECIFICATIONS The analyzer has a rugged, weatherproof, corrosion- 1.1 FEATURES AND APPLICATIONS resistant enclosure (NEMA 4X and IP65) of epoxy- The Model 54eA Analyzer/Controller with the appro- painted aluminum. It is suitable for panel, pipe, or wall priate sensor monitors and controls dissolved oxy- mounting. A hinged front cover provides convenient gen (ppm and ppb level), free chlorine, total access to wiring. Programming and calibration

Summary of the content on the page No. 8

MODEL 54eA SECTION 1.0 SPECIFICATIONS 1.2 SPECIFICATIONS - GENERAL Enclosure: Epoxy-painted (light gray) cast aluminum, Outputs: Two 4-20 mA or 0-20 mA isolated outputs. NEMA4X (IP65). 144 x 144 x 132 mm Continuously adjustable. Outputs can be assigned (5.7 x 5.7 x 5.2 in.), DIN size. to oxygen, chlorine, ozone, pH, or temperature. Output dampening is user-selectable. Maximum Front Panel: Membrane keypad with tactile feedback. load at 24 Vdc or 115/230 Vac is 500 ohms. Three green LEDs indicat

Summary of the content on the page No. 9

MODEL 54eA SECTION 1.0 SPECIFICATIONS SPECIFICATIONS — OXYGEN RECOMMENDED pH SENSORS: Measurement Range: 0-99 ppm (mg/L), 0-200% sat- Model 399-09-62, 399-14, and 399VP-09 uration See pH sensor product data sheet for complete ordering Resolution: 0.01 ppm, 0.1 ppb for 499A TrDO sen- information. sor Temperature correction for membrane permeabili- ty: automatic between 0 and 50°C (can be dis- SPECIFICATIONS — TOTAL CHLORINE abled) Measurement Range: 0-20 ppm (mg/L) as Cl 2 Calibration: automatic

Summary of the content on the page No. 10

MODEL 54eA SECTION 1.0 SPECIFICATIONS 1.3 ORDERING INFORMATION The Model 54eA Microprocessor Analyzer measures dissolved oxygen, free chlorine, total chlorine, ozone, and pH. pH is available for free chlorine only. The analyzer has an on-board pressure sensor for automatic air calibration of oxygen sensors. Amperometric measurements are fully compensated for changes in membrane permeability with temperature. Free chlorine is corrected for pH. Standard features include a three-line back-lit disp

Summary of the content on the page No. 11

MODEL 54eA SECTION 2.0 INSTALLATION SECTION 2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. Save the box. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are missing, notify Rosemount Analytical immediately. 2.2 INSTALLATION 2.2.1 General information 1. Although the controller is suitable for outdoor use, do not install it in d

Summary of the content on the page No. 12

MODEL 54eA SECTION 2.0 INSTALLATION 2.2.3 Pipe mounting FIGURE 2-2. Pipe Mounting WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH 9.52 .375 4 MOUNTING FRONT VIEW SIDE VIEW HOLES DWG. NO. REV. 40005402 E PIPE MOUNTING PN 2002577 WALL MOUNTING FIGURE 2-3. Pipe and Wall Mounting Dimensions 6

Summary of the content on the page No. 13

MODEL 54eA SECTION 2.0 INSTALLATION 2.2.4 Panel mounting FIGURE 2-4. Panel Mounting WHEN INCH AND METRIC DIMS 144 139.7 ARE GIVEN 5.7 5.5 MILLIMETER 28.72 INCH 1.17 SIDE VIEW 144 5.7 PANEL MOUNTING BRACK- ET WITH BOLTS, WASHERS AND SCREWS. 2 PLACES FRONT VIEW PANEL SUPPLIED BY OTHERS 137.9 5.43 BOTTOM VIEW PANEL FLUSH TO BEZEL 68.96 RADIUS MAX 1.52 2.715 139.7 4 PLACES .06 5.5 68.96 2.715 35 1.38 137.9 5.43 50.8 2 33 1.3 PANEL CUT-OUT INFORMATION .843 DIA 66 DWG. NO. REV. 2.6 ELECTRICAL CO

Summary of the content on the page No. 14

MODEL 54eA SECTION 3.0 WIRING SECTION 3.0 WIRING NOTE The Model 54eA analyzer leaves the factory configured for use with the Model 499ADO sensor (ppm dissolved oxygen). If a 499ADO sensor is NOT being used, turn to Section 5.5 and con- figure the transmitter for the desired measurement (ppb oxygen, oxygen measured using a steam-sterilizable sensor, free chlorine, total chlorine, monochloramine, or ozone) before wiring the sensor to the analyzer. Operating the analyzer and sensor for longer than

Summary of the content on the page No. 15

MODEL 54eA SECTION 3.0 WIRING DWG. NO. REV. 454EPH02 D FIGURE 3-1. Power Input and Relay Output Wiring for Model 54eA 9

Summary of the content on the page No. 16

MODEL 54eA SECTION 3.0 WIRING NOTE The Model 54eA analyzer leaves the factory configured for use with the Model 499ADO sensor (ppm dissolved oxygen). If a 499ADO sensor is not being used, turn to Section 5.5 and config- ure the analyzer for the desired measurement (ppb oxygen, oxygen measured using a steam- sterilizable sensor, free chlorine, total chlorine, monochloramine, or ozone) before wiring the sensor to the analyzer. Operating the analyzer and sensor for longer than five minutes while th

Summary of the content on the page No. 17

MODEL 54eA SECTION 3.0 WIRING 3.3.3 Wiring 499ACL-01 (free chlorine) sensors and pH sensors for automatic pH correction. If free chlorine is being measured using the 499ACL-01 sensor and the pH of the liquid varies more than 0.2 pH unit, a continuous correction for pH must be applied to the chlorine reading. Therefore, a pH sensor must also be wired to the 54eA controller. This section gives wiring diagrams for the pH sensors typically used. When using the 499ACL-01 sensor (free chlorine) with

Summary of the content on the page No. 18

MODEL 54eA SECTION 3.0 WIRING DWG. NO. REV. 4054eA05 A Although the blue wire is connect- ed to a terminal labeled solution ground, the blue wire does not connect to a solution ground in the sensor. The 399-14 sensor has no solution ground. The blue wire, instead, ties the preamplifier in the sensor to instrument common. FIGURE 3-6. 499ACL-01 sensor with standard cable and 399-14 pH sensor having internal preamplifier. DWG. NO. REV. 4054eA03 A FIGURE 3-7. 499ACL-01 sensor with standard cable and

Summary of the content on the page No. 19

MODEL 54eA SECTION 3.0 WIRING DWG. NO. REV. 4054eA02 B FIGURE 3-8. 499ACL-01 sensor with optimum EMI/RFI cable or Variopol cable and 399VP-09 pH sensor without internal preamplifier. DWG. NO. REV. 4054eA06 A Although the blue wire is connect- ed to a terminal labeled solution ground, the blue wire does not connect to a solution ground in the sensor. The 399-14 sensor has no solution ground. The blue wire, instead, ties the preamplifier in the sensor to instrument common. FIGURE 3-9. 499ACL-01 s

Summary of the content on the page No. 20

MODEL 54eA SECTION 3.0 WIRING DWG. NO. REV. 4054eA04 A FIGURE 3-10. 499CL-01 sensor with optimum EMI/RFI cable or Variopol cable and 399-09-62 pH sensor without internal preamplifier. 3.3.4 Wiring 438ACL-01 (pH independent free chlorine) sensors FIGURE 3-11. 498CL-01 (pH-independent free chlorine) sensor 14


Alternative user manuals
# User manual Category Download
1 Emerson Process Management DVS205 User manual Stud Sensor 6
2 Emerson Process Management - Emerson Electric Co.381 User manual Stud Sensor 0
3 Emerson Process Management - Emerson Electric Co.TF396 User manual Stud Sensor 1
4 Emerson Process Management - Emerson Electric Co.37-5392D User manual Stud Sensor 0
5 Emerson Process Management MICRO MOTION T-SERIES User manual Stud Sensor 4
6 A&D sf/sg User manual Stud Sensor 2
7 Sony ICX423AL User manual Stud Sensor 1
8 Sony E01X23A41 User manual Stud Sensor 1
9 Sony ICX418ALB User manual Stud Sensor 1
10 Agilent Technologies 81680A User manual Stud Sensor 3
11 Agilent Technologies 81689A User manual Stud Sensor 3
12 Agilent Technologies 81480A User manual Stud Sensor 1
13 Agilent Technologies 85037-90013 User manual Stud Sensor 2
14 Agilent Technologies 81682A User manual Stud Sensor 2
15 Agilent Technologies 81640A User manual Stud Sensor 1