Sierra Monitor Corporation PF5M user manual

User manual for the device Sierra Monitor Corporation PF5M

Device: Sierra Monitor Corporation PF5M
Category: Stud Sensor
Manufacturer: Sierra Monitor Corporation
Size: 0.48 MB
Added : 2/4/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sierra Monitor Corporation PF5M. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sierra Monitor Corporation PF5M.

For your convenience

If looking through the Sierra Monitor Corporation PF5M user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sierra Monitor Corporation PF5M on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sierra Monitor Corporation PF5M to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sierra Monitor Corporation PF5M User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sierra Monitor Corporation PF5M but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sierra Monitor Corporation PF5M. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Digital Flow Sensor
Instruction Manual
PFM5 Series
URL http://www.smcworld.com
Specifications are subject to change without prior notice and any obligation on the
part of the manufacturer.
The descriptions of products shown in this document may be used by the other
companies as their trademarks.
© 2006 SMC Corporation All Rights Reserved

Summary of the content on the page No. 2

CONTENTS Thank you for purchasing the SMC PFM5 Series Digital Flow Sensor. Please read this manual carefully before operating the digital Safety Instructions 2 flow sensor and make sure you understand the digital flow Names and Functions of Individual Parts 7 sensor, its capabilities and limitations. Please keep this manual handy for future reference. Model Indication Method 8 Mountin and Installation 10 OPERATOR Installation 10 Pipimg 13 • This manual has been written for those who have knowled

Summary of the content on the page No. 3

Safety Instructions The Digital Flow Sensor have in after referred to as flow sensor and this manual contain essential information for the protection of users and others from possible injury and property damage Do not operate in an environment of inflammable, explosive and to ensure correct handling. or corrosive gas. Please check that you fully understand the definition of the Fire or an explosion can result. following messages (signs) before going on to read the text, and always follow the ins

Summary of the content on the page No. 4

Safety Instructions (continued) NOTE Follow the instructions given below when handling the flow sensor. Otherwise, the flow sensor may be damaged or may Perform proper functional checks and leak tests after maintenance. fail, thereby resulting in malfunction. Stop operation when an abnormality is observed such that the flow • Make sure to use a sensor by the specified voltage. sensor does not work properly or there is a leakage of fluid. • Make sure to use specified measurement flow and operati

Summary of the content on the page No. 5

IN Safety Instructions (continued) Names and Functions of Individual Parts NOTE • Wire as short as possible to avoid the affect of noise and surge. Flow display Flow adjustment valve • Never use in the presence of explosive gases. Knurl • Do not use in an area where magnetic field is generated to avoid Power source display malfunction of sensor. • Do not operate where the flow sensor is exposed to water. • Do not use in an area containing oil or chemicals. • Do not apply heat cycle to the flow s

Summary of the content on the page No. 6

Nil Model Indication Method 5 PFM - - - - Type Model Contente Option2 5 Separate type sensor part Refer to the following table. Rated flow range (flow range) Option1 Model Contente Model Contente 10 0.2 to 10(5) /min Nil Connecter lead wire is included (2m) 25 0.5 to 25(12.5) /min W Connecter lead wire is included (2m) + Rubber cover 50 1 to 50(25) /min Z No option 11 2 to 100(50) /min Note 1) Value in ( ) is the flow rate when CO2 is used. Proofr

Summary of the content on the page No. 7

1 IN A Mounting and Installation Installation bracket mounting •Fasten the bracket mounting screws at a clamping torque of How to mount 0.5 0.05N·m. Panel Mount mounting •Insert Panel Mount Adapter B supplied as an accessory into Section A of Panel Mount Adapter A. Attached tapping screw Push Panel Mount Adapter B from behind till the display is fixed onto the panel. The pin of Panel Mount Adapter B engages the notched part of Panel Adapter C to fix the display. •The sensor can be mounted on a

Summary of the content on the page No. 8

Mounting and Installation (continued) DIN rail mounting (using ZS-33-R) Piping •The tightening toque for DIN rail mounting screws and joint •Keep the tightening torque when piping for the female thread. screws should be 0.4 0.05N·m. •Refer to the following table for the appropriate torque values. Nominal size of Appropriate torque screws N·m Rc1/8 7 to 9 Rc1/4 12 to 14 Through hole Bracket •Hold the metal part with the spanner when piping. Joint screw DIN rail mounting bracket DIN rail mounting

Summary of the content on the page No. 9

Mounting and Installation (continued) Output circuit Wiring Brown DC(+) Connection • Make connection after turning the power off. Black OUT1 • Use a separate route when installing wire. Load DC24V Malfunction stemming from noise may occur if wire is installed in White Select response time the same route as that of power or high-voltage cable. • Be sure to ground terminal FG when using a switching regulator Blue DC(-) obtained on the market. If analog output is performed connecting to a switchin

Summary of the content on the page No. 10

Error Indication Error indication function This function is to display error location and content when a problem or an error occurs. Error Name Error Display Error Content Troubleshooting Flow exceeds Apply flow within rated rated flow range. flow range. Flow POWER FLOW error Flow disply lamp is red. System error. Turn off the power Possible damage supply once, and then, of internal circuit. supply the power POWER FLOW System again. If error is not Erro released by this, please Power supply di


Alternative user manuals
# User manual Category Download
1 Sierra Monitor Corporation 4105 User manual Stud Sensor 1
2 Sierra Monitor Corporation PSE530 User manual Stud Sensor 0
3 A&D sf/sg User manual Stud Sensor 2
4 Sony ICX423AL User manual Stud Sensor 1
5 Sony E01X23A41 User manual Stud Sensor 1
6 Sony ICX418ALB User manual Stud Sensor 1
7 Agilent Technologies 81680A User manual Stud Sensor 3
8 Agilent Technologies 81689A User manual Stud Sensor 3
9 Agilent Technologies 81480A User manual Stud Sensor 1
10 Agilent Technologies 85037-90013 User manual Stud Sensor 2
11 Agilent Technologies 81682A User manual Stud Sensor 2
12 Agilent Technologies 81640A User manual Stud Sensor 1
13 Agilent Technologies 4A User manual Stud Sensor 1
14 Agilent Technologies E9300 User manual Stud Sensor 1
15 Agilent Technologies 3A User manual Stud Sensor 1