Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60 user manual

User manual for the device Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60

Device: Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60
Category: Switch
Manufacturer: Allied Telesis
Size: 0.73 MB
Added : 3/12/2013
Number of pages: 50
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60.

For your convenience

If looking through the Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60 User manual - Online PDF
Advertisement
« Page 1 of 50 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Allied Telesis Unmanaged Fast EthernetATFS705EFCSC60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AT-FS705E FC
AT-FS706E FC
10/100 Mbps Ethernet Switches
Installation Guide
PN 613-50221-00 Rev A

Summary of the content on the page No. 2

Copyright  2001 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp. reserv

Summary of the content on the page No. 3

Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate ra

Summary of the content on the page No. 4

Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo , vaya al Apéndice A para ver el mensaje de seguridad traducido a su idioma. Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser , skall du gå till Bilaga A för att läsa det översatta säkerhetsmeddelandet på ditt språk. iv

Summary of the content on the page No. 5

Table of Contents Electrical Safety and Emission Compliance Statement .......................iii Welcome to Allied Telesyn ..........................................................................vii Where to Find Web-based Guides ...................................................................vii Document Conventions ....................................................................................vii Contacting Allied Telesyn ..............................................................

Summary of the content on the page No. 6

Chapter 2 Installing the Switch ....................................................................................17 Reviewing Safety Guidelines ...........................................................................17 Verifying the Package Contents ......................................................................18 Selecting a Site for the Switch .........................................................................19 Installing the Twisted Pair and Fiber Optic Cabling ...........

Summary of the content on the page No. 7

Welcome to Allied Telesyn The guide contains instructions on how to install the AT-FS705E FC Series and AT-FS706E FC Series Ethernet Switches. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com contains the most recent documentation for all of our products. All product guides can be downloaded from the web site in PDF format. Document Conventions This guide uses several conventions that you should become familiar with before you begin to install the product.

Summary of the content on the page No. 8

Contacting Allied Telesyn You can contact Allied Telesyn technical support by telephone, fax, or e-mail. You can also contact technical support online through our web site. Online Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/support/supportf.asp or by accessing the Technical Support Knowledge Base from the Allied Telesyn North American web site. The Knowledge Base allows you to submit questions to our technical st

Summary of the content on the page No. 9

AT-FH705E FC and AT-FS706E FC Installation Guide E-mail Support United States and Canada TS1@alliedtelesyn.com Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands latin_america@alliedtelesyn.com Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense. To obtain an RMA number, contact Allied Telesyn’s Technical

Summary of the content on the page No. 10

FTP Server If you need a new version of management software for an Allied Telesyn managed device and you know the file name of the program, you can download the software by connecting directly to our FTP server at ftp:// gateway.centre.com. At login, enter ‘anonymous’ as the username and your e-mail address as the password. For Sales or Corporate Information Allied Telesyn International, Corp. Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 960 Stewart Drive, Suite B

Summary of the content on the page No. 11

Chapter 1 Overview The AT-FS705E FC Series and the AT-FS706E FC Series Fast Ethernet switches are unmanaged Layer 2 switches. They can be used in a variety of network configurations and topologies. You can use the switches to create small workgroups with dedicated 10/100 Mbps links to your network devices, such as workstations, servers, printers, and routers. You can also use the switches to interconnect Ethernet hubs to provide a bridge between the different workgroups of your network. Fi

Summary of the content on the page No. 12

Figure 1 and Figure 2 illustrate the front and rear panels of the AT-FS705E FC Series and AT-FS706E FC Series Ethernet switches, respectively. Twisted Pair Fiber Optic Port Fiber Optic Power LED Duplex Mode Switch Port LEDS Port LEDs 100FX 10/100TX Allied Telesyn AT-FS705E FC/SC 10BASE-T / 100BASE-TX 4 PORT ETHERNET SWITCH WITH 100FX UPLINK LNK/ACT LNK/ACT HALF 100M FULL FD 5 PWR 5 4 3 2 1 100FX DUPLEX DC In 1 2 3 4 TX 5 RX 3.3V 10Base-T/100Base-TX Ports 100Base-FX DC Power Fiber Opti

Summary of the content on the page No. 13

AT-FS705E FC and AT-FS706E FC Installation Guide 10/100 Mbps Twisted Pair Ports The AT-FS705E FC and AT-FS706E FC switches have four twisted pair ports. Type of Connector The twisted pair ports have RJ45 connectors. Speed These ports are compliant with the 10Base-T and 100Base-TX standards and are capable of either 10 Mbps or 100 Mbps operation. The ports are IEEE 802.3u Auto-negotiation-compliant, meaning the speed for each port is set automatically by the switch after determining the speed

Summary of the content on the page No. 14

Maximum Distance The maximum distance of a twisted pair cable is 100 meters (328 feet). Cable lengths that exceed this limit can result in poor or erratic network performance. Auto MDI/MDI-X An RJ45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network device can be wired as either MDI and MDI-X. Twisted pair ports on personal computers, routers, and bridges are typically wired as MDI. The twisted pair ports on switches and hubs are usually MDI-X. When connecting two network devices

Summary of the content on the page No. 15

AT-FS705E FC and AT-FS706E FC Installation Guide 100 Mbps Fiber Optic Port The AT-FS705E FC and AT-FS706E FC Ethernet switches feature one and two fiber optic ports, respectively. You can use the fiber optic ports to connect the switch to other switches or other end nodes over large distances. Type of Connector The AT-FS705E FC Series and the AT-FS706E FC Series switches come with a variety of fiber optic connectors. Contact your Allied Telesyn International sales representative for a list

Summary of the content on the page No. 16

Maximum Distance The maximum operating distance of the fiber optic ports on the AT-FS705E FC and AT-FS706E FC Ethernet switches is 2 kilometers (1.25 miles). Cable lengths that exceed this limit can result in poor or erratic network performance. Note The fiber optic port on the network device that you intend to connect to the AT-FS705E FC or AT-FS706E FC Ethernet switch must have the same operating characteristics as the fiber optic port on the switch. For example, the maximum operating di

Summary of the content on the page No. 17

AT-FS705E FC and AT-FS706E FC Installation Guide Introduction to Ethernet Switching An Ethernet switch is designed to manage the flow of data between the various devices that are connected to its ports. MAC Address Table The heart of an Ethernet switch is the Media Access Control (MAC) address table. Every device that you attach to an Ethernet network has a MAC address. This address is assigned to the device by the device’s manufacturer. For example, each network interface card (NIC) that y

Summary of the content on the page No. 18

The MAC address table in the AT-FS705E FC Series and AT-FS706E FC Series switches can store up to 4,000 MAC addresses. To prevent the table from becoming filled with addresses of end nodes that are no longer active, the switch has a MAC address aging timer. This timer will delete a MAC address from the table if it does not see a frame from the end node with the address on any port after five minutes (300 seconds). The aging timer also helps to ensure that the table is correct should an end

Summary of the content on the page No. 19

AT-FS705E FC and AT-FS706E FC Installation Guide How a switch signals an end node to stop transmitting data differs depending on the speed of the end node and switch port. Ports operating at 10 Mbps use flow control while ports operating at 100 Mbps use backpressure. For a 10 Mbps port, the switch will stop an end node from transmitting data by forcing a collision. A collision on an Ethernet network occurs when two nodes attempt to transmit data using the same data link at the same time. A

Summary of the content on the page No. 20

System LEDs The switch has a series of LEDs that you can use to determine the operating status of the system and the ports. The LEDs are described in Table 1. Table 1 System and Port LEDs LED Color Function PWR Steady Green The switch is receiving power. FD Steady Green The fiber optic port is operating in full-duplex mode. OFF The fiber optic port is operating in half-duplex mode. 100M Steady Green The twisted pair port is operating at 100 Mbps. OFF The twisted pair port is operating at 10


Alternative user manuals
# User manual Category Download
1 Allied Telesis 24i User manual Switch 24
2 Allied Telesis AT -8000S/24 User manual Switch 182
3 Allied Telesis 8100S User manual Switch 28
4 Allied Telesis 4000 Series User manual Switch 9
5 Allied Telesis 48W User manual Switch 5
6 Allied Telesis AT -8000S/48 User manual Switch 33
7 Allied Telesis 86241-06 User manual Switch 0
8 Allied Telesis 613-001480 User manual Switch 4
9 Allied Telesis 8PS User manual Switch 1
10 Allied Telesis AT-8100L/8POE User manual Switch 3
11 Allied Telesis AT-8100S/24F-LC User manual Switch 0
12 Allied Telesis AT-8000GS/48 User manual Switch 34
13 Allied Telesis AT-8100S/16F8-SC User manual Switch 3
14 Allied Telesis AT-8100S/16F8-LC User manual Switch 0
15 Allied Telesis AT-8100S/48 User manual Switch 6
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4