Black Box MT722AE-X21T user manual

User manual for the device Black Box MT722AE-X21T

Device: Black Box MT722AE-X21T
Category: Switch
Manufacturer: Black Box
Size: 0.21 MB
Added : 8/17/2014
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Black Box MT722AE-X21T. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Black Box MT722AE-X21T.

For your convenience

If looking through the Black Box MT722AE-X21T user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Black Box MT722AE-X21T on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Black Box MT722AE-X21T to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Black Box MT722AE-X21T User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Black Box MT722AE-X21T but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Black Box MT722AE-X21T. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MARCH 1995
MT720A-232T MT721AE-X21T
MT720A-35T MT722A-232T
MT720AE-X21T MT722A-35T
MT721A-232T MT722AE-X21T
MT721A-35T
Fradswitch-8A (232)
Fradswitch-8A (V.35)
Fradswitch-8A (X21)
Fradswitch-16A (232)
Fradswitch-16A (V.35)
Fradswitch-16A (X21)
Fradswitch-24A (232)
Fradswitch-24A (V.35)
Fradswitch-24A (X21)
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
CUSTOMER
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
SUPP

Summary of the content on the page No. 2

FCC AND IC STATEMENTS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADIA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC r

Summary of the content on the page No. 3

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso de

Summary of the content on the page No. 4

TABLE OF CONTENTS Contents Chapter Page 1. Specifications.....................................................................................................................................................4 2. Introduction ......................................................................................................................................................6 2.1 Overview ............................................................................................................

Summary of the content on the page No. 5

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A 1. Specifications Links (X.25) Characteristics Number of Links 3 Data Rate All the links aggregate up to 2.15 Mbps Interface RS-232/V.24, X.21, or V.35 (selected when you order) Connectors RS-232/V.24 25-pin D-type, female X.21 15-pin, female V.35 34-pin, female Protocol Complies with ITU X.25, LAPB (Blue Book, 1988) Configuration Clocking External clocking for receive and transmit paths Selectable Parameters Frame window (k); Packet window (w); Tim

Summary of the content on the page No. 6

CHAPTER 1: Specifications General Indicators (9) LEDs: Power; Main links activity; Sub-channels activity; (3) Loss of synchronization; Error; Overflow; Test Operating Temperature 32 to 122°F (0 to 50°C) Humidity Up to 90%, noncondensing Power Supply Voltage 115- or 230-VAC (depending which model you ordered), 50/60 Hz Consumption 15W Fuse 125 mA, 250V Size MT720A units: 1.7"H x 17"W x 9.5"D (4.4 x 43.2 x 24.1 cm); MT721A and MT722A units: 1.7"H x 17"W x 11.7"D (4.4 x 43.2 x 29.7 cm) Weight MT

Summary of the content on the page No. 7

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A 2. Introduction 2.1 Overview The Fradswitch-8A, Fradswitch-16A, and Fradswitch-24A are combinations of a high-performance X.25/Frame Relay PAD (Packet Assembler/Disassembler) and a Packet Switch, for concentrating and switching data in an X.25/Frame Relay environment. A Fradswitch can connect up to eight, sixteen, or twenty-four asynchronous channels, and up to three synchronous links, and perform packet-switching functions between all links (X.25 to

Summary of the content on the page No. 8

CHAPTER 2: Introduction • Routing between several Frame Relay devices or networks (Frame Relay to Frame Relay switching). (See Figure 2-5.) • Connection of devices supporting HDLC protocol to the X.25 or Frame Relay network. (See Figure 2-6.) FRADSWITCH-8A STM LINK X.25 STAT MUX NETWORK X.25 LINK X.25 PUBLIC DATA NETWORK X.25 LINK FRADSWITCH-8A FRADSWITCH-8A Figure 2-1. Fradswitch-8A serving as backbone for private X.25 data networks. 7

Summary of the content on the page No. 9

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A FRADSWITCH-8A STM 64 Kbps X.25 STAT-24 PUBLIC (MX868A) X.25 NETWORK X.25 COMPUTER Figure 2-2. Fradswitch-8A providing X.25 switching and async channel expansion. X.25 NETWORK ACCESS 128 Kbps X.25 PUBLIC NETWORK ASYNC LINK X.25 REDUNDANT NETWORK ACCESS 19.2 Kbps FRADSWITCH-8A ASYNC CHANNELS Figure 2-3. Fradswitch-8A serving as a PAD with redundant link and load sharing. One link configured as async channel. 8

Summary of the content on the page No. 10

CHAPTER 2: Introduction (B) ASYNC FRAME FRAME X.25 FRAME RELAY RELAY RELAY NETWORK FRADSWITCH-8A FRADSWITCH-8A (A) Figure 2-4. (a) Fradswitch-8A operating as a switch at the user side: Conversion of Frame Relay to X.25. (b) Fradswitch-8A operating as a FRAD at the user side: Conversion of Frame Relay to async. PRIVATE DATA NETWORK FRADSWITCH-8A FRAME RELAY FRAME FRADSWITCH-8A RELAY FRAME FRAME RELAY FRADSWITCH-8A RELAY Figure 2-5. Fradswitch-8A serving as a backbone for Frame Relay private data

Summary of the content on the page No. 11

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A ETHERNET ETHERNET X.25 OR FRAME RELAY NETWORK BRIDGE BRIDGE TRANSPARENT HDLC TRANSPARENT HDLC X.25 OR FRAME RELAY X.25 OR FRAME RELAY FRADSWITCH-8A FRADSWITCH-8A Figure 2-6. Fradswitch-8A connecting HDLC devices over X.25 or Frame Relay. 2.3 X.25 Link Features When the Fradswitch links are configured for X.25, they operate synchronously at data rates up to 2.15 Mbps. The links interface is DTE or DCE, and the data rate is determined by the external

Summary of the content on the page No. 12

CHAPTER 2: Introduction The Fradswitch employs a unique funneling method for controlling network congestion and moderating feeder throughput speed. CCLM and LMI management protocols are supported, and operation is in compliance with ANSI T1.606, T1.619, T1.617 Annex D, and ITU Q.922, Annex A. 2.5 HDLC Link Features The Fradswitch links can be programmed to operate with transparent HDLC allowing computers, bridges, and HDLC communication devices to be connected over X.25 or Frame Relay networks.

Summary of the content on the page No. 13

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A The Fradswitch supports four call-initiation methods, independently selectable for each channel. 1) Manual (regular) call initiation, whereby the user provides all the information required to set up the call by entering an X.28 command. 2) Mnemonic call initiation, whereby the user need only enter a mnemonic (call ID). The channel PAD then retrieves the call-setup information from the Fradswitch’s memory. 3) Automatic call initiation (autocall). The

Summary of the content on the page No. 14

CHAPTER 2: Introduction The command facility supports the configuration of both the local and the remote channel PADs. It includes a help function, which provides information on the available PAD commands, and on the purpose and format of each command. The Fradswitch’s command facility can be accessed from any channel, and from any place in the X.25 network. Simultaneous access from several channels is possible, but a warning is given if a user connects to the facility when someone else is alre

Summary of the content on the page No. 15

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A For activities that involve repetitive preparation of the same set of parameters, such as channel configuration, profiles, call IDs, etc., the Fradswitch provides a time-saving duplicate function, which allows copying an already-prepared data set as a basis for the preparation of a new set. Another valuable convenience is the display of reports that summarize the existing data for each type of configurable data item. In addition, on-line help is av

Summary of the content on the page No. 16

CHAPTER 2: Introduction • Compression of data stored in the Fradswitch’s nonvolatile memory, to allow maximum use of the available storage capacity. The compression is performed by rearranging the data stored in the memory, to close gaps between data blocks that appear naturally when the stored information is modified. • Resetting and reloading of the default configuration. This function allows a remote supervisor to perform these activities, which would otherwise require the dispatching of ser

Summary of the content on the page No. 17

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A Total number of frames transmitted and received by layer 1 (the physical layer). Total number of information frames transmitted and received by layer 2 (the link control layer). Total number of information frames transmitted and received by layer 3 (the X.25 layer). Current X.25 synchronization status, and the total number of X.25 synchronization losses. The average number of data buffers in the Fradswitch “pool,” and the recorded minimum number of b

Summary of the content on the page No. 18

CHAPTER 2: Introduction • LAPB (layer 2) statistics: Total number of I, RR, RNR, REJ, and FRMR frames transmitted and received by layer 2. Number of transmission and reception errors. LAPB state. Current frame size. •X.25 (layer 3) statistics: Total number of I, clear, reset, and restart packets transmitted and received by layer 3. Number of logical group in use. Current packet size. 2.18 Diagnostic Features Upon power-up or after reset, the Fradswitch performs a self-test, during which all its

Summary of the content on the page No. 19

FRADSWITCH-8A, FRADSWITCH-16A, FRADSWITCH-24A 3. Installation This chapter provides mechanical and electrical installation procedures for the Fradswitch. The Fradswitch is delivered completely assembled. It’s designed to be installed as a desktop unit or to be mounted in a 19-inch rack. After installing the unit, refer to Chapter 2 of the Packet Switching Guide for system configuration information and procedures. 3.1 Unpacking Perform a preliminary inspection of the equipment container before

Summary of the content on the page No. 20

CHAPTER 3: Installation Ambient Requirements The ambient operating temperature of the Fradswitch should be 32 to 122°F (0 to 50°C), at a relative humidity of up to 90%, noncondensing. 3.3 Fradswitch Hardware Configuration Information 3.3.1 GENERAL INFORMATION The Fradswitch contains three different types of printed circuit boards (see Figure 3-1): • The main board. This board contains most of the Fradswitch circuits, and has two jumpers. • The extension board. • Three main link interface board


Alternative user manuals
# User manual Category Download
1 Black Box 26720 User manual Switch 6
2 Black Box 26592 User manual Switch 0
3 Black Box 26546 User manual Switch 1
4 Black Box 4site User manual Switch 0
5 Black Box 26615 User manual Switch 1
6 Black Box 24985 User manual Switch 0
7 Black Box 26611 User manual Switch 0
8 Black Box 26715 User manual Switch 0
9 Black Box 26573 User manual Switch 0
10 Black Box AC552A-2 User manual Switch 0
11 Black Box ACR6216A User manual Switch 1
12 Black Box ACS2209A-R2-MM User manual Switch 5
13 Black Box ACS2009A-R2-MM User manual Switch 1
14 Black Box ACR6208A User manual Switch 1
15 Black Box AC509A User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4