Black Box SW981A user manual

User manual for the device Black Box SW981A

Device: Black Box SW981A
Category: Switch
Manufacturer: Black Box
Size: 0.14 MB
Added : 8/17/2014
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Black Box SW981A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Black Box SW981A.

For your convenience

If looking through the Black Box SW981A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Black Box SW981A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Black Box SW981A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Black Box SW981A User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Black Box SW981A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Black Box SW981A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MARCH 2000
SW980A SW980AE
SW981A SW981AE
SW982A SW982AE
Local/Remote Electronic Switches
CUSTOMER
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
SUPPORT
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
INFORMATION
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
2 TO 1
LOCAL / REMOTE
SWITCH
B
REMOTE
A
A B
PWR
®
R
BLACK BO

Summary of the content on the page No. 2

FCC/IC/CE STATEMENTS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO-FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rule

Summary of the content on the page No. 3

LOCAL/REMOTE ELECTRONIC SWITCHES NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser segui

Summary of the content on the page No. 4

NOM STATEMENT, TRADEMARKS 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, un

Summary of the content on the page No. 5

LOCAL/REMOTE ELECTRONIC SWITCHES Contents Chapter Page 1. Specifications ............................................................................................. 5 2. Introduction ............................................................................................... 7 3. Installation and Configuration ................................................................. 8 3.1 Before You Install ................................................................................ 8 3.2 T

Summary of the content on the page No. 6

CHAPTER 1: Specifications 1. Specifications Compliance — FCC Part 15 Subpart J Class A, IC Class/classe A Data Rate — Up to 256 kbps typical; higher speeds possible with careful consideration of cabling and equipment requirements User Controls — All models: Remote switching either through TTL, RS-232, RS-422/485, or other active drivers or through dry-contact closure; SW980 and SW982 models: (1) Rear-mounted 2-position DIP switch for grounding; SW981 models: (2) Rear-mounted 2-position DIP switc

Summary of the content on the page No. 7

LOCAL/REMOTE ELECTRONIC SWITCHES Remote Input Logic Levels — V greater than 2.5 volts, maximum +15 volts; IH V less than 0.5 volts, minimum –15 volts IL NOTE For dry-contact operation, the total external- connection DC resistance must be less than 240 ohms when the dry contact is closed for the Local/Remote Electronic Switch to correctly read this condition as a “low” input. Power — SW980A, SW981A, SW982A: From wallmount power supply PS154: Input: 120 VAC, 60 Hz; Output: 17 VAC CT; SW980AE, SW98

Summary of the content on the page No. 8

CHAPTER 2: Introduction 2. Introduction Switching between data lines manually can often damage the connected equipment, because this relatively slow and imprecise action can cause data-line surges and spikes large enough to damage today’s sensitive circuitry. With the Local/Remote Electronic Switches, you can eliminate this potential hazard. Their electronic switching action provides surgeless, spikeless changeovers—something a mechanical switch just can’t do. In addition, these switches can be

Summary of the content on the page No. 9

LOCAL/REMOTE ELECTRONIC SWITCHES 3. Installation and Configuration 3.1 Before You Install Check the box and its contents before you begin installing your Local/Remote Electronic Switch. You should have received one Switch unit, one AC power supply, and one copy of this manual. If you didn’t receive all of these items, or if they have sustained damage that does not seem to be shipping-related, notify Black Box right away. If they have sustained impact or water damage that seems to have happened d

Summary of the content on the page No. 10

CHAPTER 3: Installation and Configuration 3.2 The Setup Procedure Installing and configuring a Local/Remote Electronic Switch is relatively quick and easy, and will vary only slightly depending on which model you’ve chosen. Follow these steps: (Steps 1 through 4 are for remotely switched applications only:) 1. Make sure that the Switch is unplugged (is not receiving AC power). Open the Switch by unscrewing the two screws on the bottom of the unit (save these screws) and removing the top of the u

Summary of the content on the page No. 11

LOCAL/REMOTE ELECTRONIC SWITCHES W1 A B C TB1 REAR FRONT Figure 3-1. PCB layout of the SW980 models. 10

Summary of the content on the page No. 12

CHAPTER 3: Installation and Configuration TB1 A B C W1 REAR FRONT Figure 3-2. PCB layout of the SW981 models. 11

Summary of the content on the page No. 13

LOCAL/REMOTE ELECTRONIC SWITCHES W2 TB1 A W3 B A C B C FRONT REAR Figure 3-3. PCB layout of the SW982 models. 12

Summary of the content on the page No. 14

CHAPTER 3: Installation and Configuration (text continued from page 9) 3. If you will be performing remote switching using a cable that is unterminated at the Switch end, attach the cable’s wires to the appropriate positions of the 4-position terminal block labeled “TB1” (refer to Figures 3-1 through 3-3 on pages 10 through 12 and to Tables 4-1 and 4-2 on pages 20 and 21). Connect the ground of the remote driver, or one side of the dry contact, to (either of) the terminal block’s ground pin(s).

Summary of the content on the page No. 15

LOCAL/REMOTE ELECTRONIC SWITCHES B A BB AA SERIAL PARALLEL REMOTE Figure 3-5. Rear panel of the SW981 models. B A SERIAL PARALLEL REMOTE C E D Figure 3-6. Rear panel of the SW982 models. 14

Summary of the content on the page No. 16

CHAPTER 3: Installation and Configuration 6. Set the DIP switch(es) as appropriate for your application. Refer to Table 3-1 and Figure 3-7 below, and keep in mind that OFF = UP and ON = DOWN. Table 3-1. Possible Settings for Switches S2 and S3 All 25 leads of the Local/Remote Electronic Switch’s DB25 connectors are straight- through and are isolated from one another. In RS-232 and DB25 parallel applications, we recommend that you use DIP switches S2 and S3 to make a “common” ground connection;

Summary of the content on the page No. 17

LOCAL/REMOTE ELECTRONIC SWITCHES 7. Put the Switch in the site you’ve selected. 8. Shut off the equipment you plan to connect to the Switch. 9A. SW980 and SW982 units only: Connect the cable from the “common” device (the one that’s going to access—or be shared by—the other devices) to the common connector (marked “C”) on the Switch’s rear panel. Connect the cables from the “branch” devices (those that will share—or be intermittently accessed by—the other device) to the branch connectors (marked

Summary of the content on the page No. 18

CHAPTER 4: Operation 4. Operation 4.1 Local Switching 4.1.1 ABC AND ABCDE SWITCHES (SW980 AND SW982 UNITS) Refer to Figure 4-1 below: Test your Local/Remote Electronic Switch system by having the common device send data to, or receive data from, branch devices “A” and “B” (and, for SW982 units, “D” and “E”), one after the other. Switch between branch devices by manually turning the knob on the Switch’s front panel. ABC SWITCH SWITCHED A COMMON C SWITCHED B Connections made are AC and BC -“C” IS

Summary of the content on the page No. 19

LOCAL/REMOTE ELECTRONIC SWITCHES 4.1.2 X SWITCHES (SW981 UNITS) Refer to Figure 4-2 below: Test your Local/Remote Electronic Switch system by having each source device (“A” and “B”) send data to each destination device (“AA” and “BB”), one after the other. Switch between data pathways by manually turning the knob on the Switch’s front panel. “X” SWITCH A AA B BB Connections made are A-AA & B-BB or A-BB & B-AA Figure 4-2. Switching in the SW981 models. 18

Summary of the content on the page No. 20

CHAPTER 4: Operation 4.2 Remote Switching When you do remote switching, keep these things in mind: • The knob on the Switch’s front panel must be in the “REMOTE” position. • The Switch interprets any voltage more negative than approximately 1.4 volts as a “low” and any voltage more positive than approximately 1.4 volts as a “high” (see the “Remote Input Logic Levels” spec in Chapter 1 for maximum and minimum switching points). • In dry-contact applications, the Switch will read a “low” when the


Alternative user manuals
# User manual Category Download
1 Black Box 26720 User manual Switch 6
2 Black Box 26592 User manual Switch 0
3 Black Box 26546 User manual Switch 1
4 Black Box 4site User manual Switch 0
5 Black Box 26615 User manual Switch 1
6 Black Box 24985 User manual Switch 0
7 Black Box 26611 User manual Switch 0
8 Black Box 26715 User manual Switch 0
9 Black Box 26573 User manual Switch 0
10 Black Box AC552A-2 User manual Switch 0
11 Black Box ACR6216A User manual Switch 1
12 Black Box ACS2209A-R2-MM User manual Switch 5
13 Black Box ACS2009A-R2-MM User manual Switch 1
14 Black Box ACR6208A User manual Switch 1
15 Black Box AC509A User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4