Cabletron Systems 2E43-27R user manual

User manual for the device Cabletron Systems 2E43-27R

Device: Cabletron Systems 2E43-27R
Category: Switch
Manufacturer: Cabletron Systems
Size: 1.27 MB
Added : 5/21/2013
Number of pages: 164
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cabletron Systems 2E43-27R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cabletron Systems 2E43-27R.

For your convenience

If looking through the Cabletron Systems 2E43-27R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cabletron Systems 2E43-27R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cabletron Systems 2E43-27R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cabletron Systems 2E43-27R User manual - Online PDF
Advertisement
« Page 1 of 164 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cabletron Systems 2E43-27R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cabletron Systems 2E43-27R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


2E42-27/2E42-27R/2E43-27/2E43-27R
SmartSwitch 2200
User’s Guide
2 16 18 20
4 6 8 10 12 14 22 24
1 3 5 7 9 11 13 15 17 19 21 23
PWR
RESET CPU
25 26
2E42-27 COM 1X 3X 5X 7X 9X 11X 13X 15X 17X 19X 21X 23X
20 22
2 4 6 8 10 12 14 16 18 24
1 3 5 7 9 11 13 15 17 19 21 23
PWR
RESET CPU
25 26
2E43-27 COM
9031960-05

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE F

Summary of the content on the page No. 4

Notice INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

Summary of the content on the page No. 5

Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This

Summary of the content on the page No. 6

Notice SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE FE-100F3 FAST ETHERNET INTERFACE MODULE, FPIM-05 AND FPIM-07 FDDI PORT INTERFACE MODULES, AND APIM-29 ATM PORT INTERFACE MODULE USE CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING THESE MODULES. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The

Summary of the content on the page No. 7

Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir

Summary of the content on the page No. 8

Notice vi 2E42-27/2E42-27R/2E43-27/2E43-27R User’s Guide

Summary of the content on the page No. 9

CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Guide......................................................................... 1-1 1.2 Structure of This Guide................................................................ 1-1 1.3 2E4X-27 Features ....................................................................... 1-2 1.4 2E4X-27 Overview....................................................................... 1-4 1.4.1 Connectivity ....................................................

Summary of the content on the page No. 10

Contents 3.4 Connecting to the Network...........................................................3-9 3.4.1 Connecting UTP Cables to Ports 1 Through 24..............3-9 3.4.1.1 2E42-27 or 2E42-27R Cable Connections....3-10 3.4.1.2 2E43-27 or 2E43-27R Cable Connections....3-11 3.4.2 Connecting a UTP Segment to the FE-100TX ..............3-13 3.4.3 Connecting a Fiber Optic Segment to the FE-100FX and FE-100F3..............................................3-15 3.5 Completing the Installation..

Summary of the content on the page No. 11

Contents 5.8 SNMP Community Names Screen ............................................ 5-31 5.8.1 Establishing Community Names................................... 5-32 5.9 SNMP Traps Screen.................................................................. 5-34 5.9.1 Configuring the Trap Table ........................................... 5-35 5.10 Switch Configuration Screen ..................................................... 5-36 5.10.1 Setting the STA..........................................

Summary of the content on the page No. 12

Contents APPENDIX A SPECIFICATIONS A.1 Device Specifications.................................................................. A-1 A.2 Physical Properties ..................................................................... A-1 A.3 Electrical Specifications .............................................................. A-1 A.4 Environmental Requirements...................................................... A-2 A.5 Input/Output Ports......................................................

Summary of the content on the page No. 13

CHAPTER 1 INTRODUCTION Welcome to the 2E42-27/2E42-27R/2E43-27/2E43-27R SmartSwitch 2200 User’s Guide. This guide describes the 2E42-27, 2E42-27R, 2E43-27, and 2E43-27R SmartSwitch 2200 devices and provides information concerning network requirements, installation, troubleshooting, and the use of Local Management. 1.1 USING THIS GUIDE Read through this guide completely to understand the 2E42-27, 2E42-27R, 2E43-27, and 2E43-27R features, capabilities, and Local Manag

Summary of the content on the page No. 14

Chapter 1: Introduction Appendix A, Specifications, contains information on functionality and operating specifications, connector pinouts, environmental requirements, and physical properties. Appendix B, FE-100TX, FE-100FX, and FE-100F3 Specifications, contains information about FE-100TX pinouts and information concerning cable types used with the FE-100FX and FE-100F3. Appendix C, Optional Installations and Mode Switch Bank Settings, describes how to install optional Fast Ethe

Summary of the content on the page No. 15

2E4X-27 Features • A 24-port high-speed workgroup switch with two optional ports for Fast Ethernet Interface Modules providing high speed uplinks to 100 Mbps Fast Ethernet technologies and one optional port for a High Speed Interface Module (HSIM). The HSIM provides additional connectivity to various networking technologies. • Full Duplex Switched Ethernet (FDSE) support for 20 Mbps or 200 Mbps Fast Ethernet links to bandwidth intensive users/servers. • SmartTrunk, whi

Summary of the content on the page No. 16

Chapter 1: Introduction 1.4 2E4X-27 OVERVIEW The 2E4X-27 is a 27-port high-speed network switching device that supports traditional switching (bridging) and Cabletron Systems SecureFast Switching Virtual Network technology. Ports 25 and 26 support optional Fast Ethernet Interface Modules and can provide uplinks to 100BASE-TX or 100BASE-FX Fast Ethernet networks. Port 27 supports an optional High Speed Interface Module (HSIM) that provides additional connectivity to various networ

Summary of the content on the page No. 17

2E4X-27 Overview All of the devices have two front panel slots (ports 25 and 26) for optional Fast Ethernet Interface Modules to support an uplink to 100 Mbps Fast Ethernet backbones or a high speed connection to a local server. There is also space for an optional HSIM to provide additional connectivity to various networking technologies. 1.4.2 Full Duplex Switched Ethernet Each switched Ethernet port supports full wire-speed Ethernet communications and can be configured to o

Summary of the content on the page No. 18

Chapter 1: Introduction 1.4.4 Runtime IP Address Discovery This feature enables the 2E42-27 to automatically accept an IP address from a Boot Strap Protocol (BootP) server on the network into NVRAM without requiring a user to enter an IP address through Local Management. When the 2E42-27 is connected to the network and powered up, Runtime IP Address Discovery (RAD) checks the 2E42-27 for an IP address. If one has not yet been assigned (2E42-27 IP address set to 0.0.0.0), RAD checks

Summary of the content on the page No. 19

2E4X-27 Overview 1.4.6 Switching Options The 2E4X-27 provides 802.1D Switching, 802.1Q switching or SecureFast Switching Virtual Network Services between all of the front panel interfaces including any installed Fast Ethernet Interface Modules and HSIM. 802.1Q switching and SecureFast switching allow for future migration to Virtual Network technologies without requiring the replacement of existing equipment. 1.4.7 Standards Compatibility The 2E4X-27 provides IEEE 802.1D Spanning

Summary of the content on the page No. 20

Chapter 1: Introduction 1.4.10 Optional Features Options for the 2E4X-27 include Fast Ethernet Interface Modules and High Speed Interface Modules to add additional interface capability. Cabletron Systems provides Fast Ethernet Interface Modules to support uplinks to 100 Mbps Ethernet backbones or high speed connections to local servers. The Fast Ethernet Interface Modules are listed in Table 1-1. . Table 1-1 Fast Ethernet Interface Modules P/N Description Application Supports Catego


Alternative user manuals
# User manual Category Download
1 Cabletron Systems 150 User manual Switch 3
2 Cabletron Systems 2200 User manual Switch 2
3 Cabletron Systems 2E43-51 User manual Switch 1
4 Cabletron Systems 2E42-27 User manual Switch 4
5 Cabletron Systems 2E48-27R User manual Switch 2
6 Cabletron Systems 3H08-04 User manual Switch 1
7 Cabletron Systems 42 User manual Switch 1
8 Cabletron Systems 2H33-37R User manual Switch 1
9 Cabletron Systems 3H02-04 User manual Switch 1
10 Cabletron Systems 5500 User manual Switch 0
11 Cabletron Systems 6E132-25 User manual Switch 1
12 Cabletron Systems 6H253-13 User manual Switch 1
13 Cabletron Systems 6C105 User manual Switch 3
14 Cabletron Systems 6H128-08 User manual Switch 1
15 Cabletron Systems 6A000 User manual Switch 1
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4