Brocade Communications Systems Brocade Network OS 2.1 user manual

User manual for the device Brocade Communications Systems Brocade Network OS 2.1

Device: Brocade Communications Systems Brocade Network OS 2.1
Category: Switch
Manufacturer: Brocade Communications Systems
Size: 0.3 MB
Added : 5/21/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Brocade Communications Systems Brocade Network OS 2.1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Brocade Communications Systems Brocade Network OS 2.1.

For your convenience

If looking through the Brocade Communications Systems Brocade Network OS 2.1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Brocade Communications Systems Brocade Network OS 2.1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Brocade Communications Systems Brocade Network OS 2.1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Brocade Communications Systems Brocade Network OS 2.1 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Brocade Communications Systems Brocade Network OS 2.1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Brocade Communications Systems Brocade Network OS 2.1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

53-1002606-06
®
18 January 2013
Network OS
Documentation Updates
Supporting Network OS v2.1.x

Summary of the content on the page No. 2

Copyright © 2012 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, MLX, NetIron, SAN Health, ServerIron, TurboIron, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or servic

Summary of the content on the page No. 3

Contents About This Document How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . v What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi Com

Summary of the content on the page No. 4

Modified messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Chapter 4 Brocade VDX 6710-54 Hardware Reference Manual Chapter 4, Brocade VDX 6710-54 Operation . . . . . . . . . . . . . . . . . .29 Chapter 5, FRU Removal and Replacement Procedures . . . . . . . . .29 Chapter 5 Brocade VDX 6720 Hardware Reference Manual Chapter 4, Brocade VDX 6720 Operation . . . . . . . . . . . . . . . . . . . . . 31 Chapter 5, FRU Removal and Replacement Procedures . . . . . .

Summary of the content on the page No. 5

About This Document In this chapter •How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v •Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v •What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi •Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi •Notice to the reader . . . . . . . .

Summary of the content on the page No. 6

What’s new in this document This document has been updated for Network OS v2.1.2 with information on: • restrict-flooding command • vCenter discovery commands • Added the new and modified messages in Chapter 3, “Network OS Message Reference”. • Revised description for the “chassis fan airflow-direction” command in Chapter 2, “NOS CLI Command Reference”. Document conventions This section describes text formatting conventions and important notice formats used in this document. Text formatting T

Summary of the content on the page No. 7

... Repeat the previous element, for example “member[;member...]” value Fixed values following arguments are printed in plain font. For example, --show WWN | Boolean. Elements are exclusive. Example: --show -mode egress | ingress Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance, or advice, emphasizes important information, or provides a

Summary of the content on the page No. 8

Notice to the reader This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations. These references are made for informational purposes only. Corporation Referenced Trademarks and Products Microsoft Corporation Windows, Windows NT, Internet Explorer Oracle Corporation Oracle, Java Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover IBM BladeCenter Advanced Management Mod

Summary of the content on the page No. 9

Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available: 1. General Information • Switch model • Switch operating system version • Software name and software version, if applicable • Error numbers and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately

Summary of the content on the page No. 10

x Network OS Documentation Update 53-1002606-06

Summary of the content on the page No. 11

Chapter NOS Administrator’s Guide 1 In this chapter •New Content for the NOS Administrator’s Guide. . . . . . . . . . . . . . . . . . . . . . . 1 New Content for the NOS Administrator’s Guide The updates in this chapter are for the Network OS Administrator’s Guide Supporting Network OS v2.1.1 (53-1002491-01), originally published in December 2011. NOTE The updates are arranged by the chapter names as they appear in the original document. Chapter 6, Installing and Maintaining Firmware Replace th

Summary of the content on the page No. 12

1 Chapter 8, Security switch# firmware download usb directory firmware\NOS_v2.1.1 5. Optional: Unmount the USB storage device. switch# usb off Trying to disable USB device. Please wait... USB storage disabled. Chapter 8, Security Add the following section after “TACACS+ server parameters” on page 86. This update only applies to Network OS v2.1.1b or higher: TACACS+ service in a mixed vendor environment Network OS v2.1.x supports Terminal Access Controller Access-Control System Plus (TACACS+)

Summary of the content on the page No. 13

1 Chapter 9, FIPS Support } Or group = { default service = permit service = exec { priv-lvl=15 optional brcd-role = admin } } user = { Member = } Add the following note to the section “Adding a RADIUS server” on page 87: NOTE The maximum supported length for the RADIUS hostname is 40 characters. Add the following note to the section “Changing a RADIUS server” on page 87: NOTE The maximum supported length for the RADIUS host

Summary of the content on the page No. 14

1 Chapter 23, Configuring LLDP 1. Log in to any switch in a Brocade VCS Fabric cluster. 2. In the global configuration mode, enter the interface command to select the RBridge/slot/port for which you want to enable edge-loop detection. 3. In the interface configuration mode, enter the edge-loop-detection vlan command to specify the VLAN you want ELD to monitor on this port. If you do not specify a VLAN, the command fails. 4. Optional: Enter the edge-loop-detection port-priority command to speci

Summary of the content on the page No. 15

Chapter NOS CLI Command Reference 2 In this chapter •New commands in the Network OS Command Reference . . . . . . . . . . . . . . . 5 •Modified commands in Network OS Command Reference . . . . . . . . . . . . . 10 •Deleted commands in Network OS Command Reference . . . . . . . . . . . . . . 22 New commands in the Network OS Command Reference Add the following new commands to the Network OS Command Reference Supporting Network OS v2.1.1 (53-1002492-01), originally published in December 2011. c

Summary of the content on the page No. 16

2 chassis fan airflow-direction Examples To specify the fan airflow-direction: switch# chassis fan airflow-direction port-side-exhaust Previous configuration : port-side-intake Current configuration : port-side-exhaust System fan airflow-direction changes will be effective after reboot!! See Also None 6 Network OS Documentation Update 53-1002606-06

Summary of the content on the page No. 17

2 restrict-flooding restrict-flooding Restricts the system-wide egress flooding behavior on port-profile ports. Synopsis restrict-flooding no restrict-flooding Operands None Defaults By default, this feature is disabled. Command Port-profile mode Modes Description This command allows you to restrict the system-wide egress flooding behavior on port-profile ports. After entering this command, only egress traffic for the associated port-profiles on that port will be allowed. Usage Use the no r

Summary of the content on the page No. 18

2 vcenter discovery ignore-delete-all-response vcenter discovery ignore-delete-all-response Configures a mode to ignore the “delete-all” responses from vCenter. Synopsis vcenter vcenter-name discovery ignore-delete-all-response {number | always} Operands vcenter-name The name of the vCenter. number Number of Discovery Cycles to ignore. The range of valid values is from 1 through 9999 cycles. always Always ignore delete-all responses from vCenter. Defaults By default, this feature is disabled.

Summary of the content on the page No. 19

2 vcenter discovery timeout vcenter discovery timeout Configures the timeout for the response from vCenter server. Synopsis vcenter vcenter-name discovery timeout number Operands vcenter-name The name of the vCenter. number Discovery timeout in minutes. The range of valid values is from 1 through 180 minutes. Defaults The default value is 60 minutes. Command Global configuration mode Modes Description This command configures the timeout for the response from vCenter server during the polling

Summary of the content on the page No. 20

2 Modified commands in Network OS Command Reference Modified commands in Network OS Command Reference Modify the following commands in the Network OS Command Reference Supporting Network OS v2.1.1 (53-1002492-01), originally published in December 2011. dpod Manages Dynamic Ports on Demand (POD) assignments. Synopsis dpod rbridge-id/slot/port {reserve | release} Operands rbridge-id Specifies a switch by its RBridge identifier. slot Specifies the slot number. port Specifies the port number. re


Alternative user manuals
# User manual Category Download
1 Brocade Communications Systems 7800 User manual Switch 44
2 Brocade Communications Systems 6520 User manual Switch 8
3 Brocade Communications Systems 7500E User manual Switch 2
4 Brocade Communications Systems 8000 User manual Switch 0
5 Brocade Communications Systems 6510 User manual Switch 33
6 Brocade Communications Systems Brocade VDX 8770-4 User manual Switch 2
7 Brocade Communications Systems Brocade VDX 6710-54 User manual Switch 22
8 Brocade Communications Systems SilkWorm 3200 User manual Switch 18
9 Brocade Communications Systems SilkWorm 24000 User manual Switch 13
10 Brocade Communications Systems Brocade VDX 6720 User manual Switch 22
11 Brocade Communications Systems Brocade VA-40FC User manual Switch 0
12 Brocade Communications Systems SilkWorm 3800 User manual Switch 8
13 Brocade Communications Systems Brocade ICX 6650 6650 User manual Switch 3
14 Brocade Communications Systems VA-40FC User manual Switch 0
15 Brocade Communications Systems Upgrade Pef IPMC5000PEF IPMC5000PEF User manual Switch 1
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4