Maretron SIM100 user manual

User manual for the device Maretron SIM100

Device: Maretron SIM100
Category: Switch
Manufacturer: Maretron
Size: 0.47 MB
Added : 8/8/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Maretron SIM100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Maretron SIM100.

For your convenience

If looking through the Maretron SIM100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Maretron SIM100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Maretron SIM100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Maretron SIM100 User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Maretron SIM100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Maretron SIM100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

® ®






SIM100
Switch Indicator Module

User’s Manual



Revision 1.0















Copyright © 2008 Maretron, LLP All Rights Reserved

Maretron, LLP
rd
9014 N. 23 Ave #10
Phoenix, AZ 85021-7850
http://www.maretron.com


Maretron Manual Part #: M001801

Revision 1.0 Page i

Summary of the content on the page No. 2

SIM100 User's Manual Revision History Revision Description 1.0 Original document Page ii Revision 1.0

Summary of the content on the page No. 3

® ® Table of Contents 1  Introduction ........................................................................................................................... 1  1.1  Firmware Revision .................................................................................................... 1  1.2  SIM100 Features ...................................................................................................... 1  1.3  Quick Install ......................................................

Summary of the content on the page No. 4

Summary of the content on the page No. 5

® ® 1 Introduction Congratulations on your purchase of the Maretron Switch Indicator Module. Maretron has designed and built your SIM100 to the highest standards for years of dependable and accurate service. Maretron’s Switch Indicator Module monitors switch closure devices including, but not limited to, safety equipment (e.g., heat, smoke, carbon monoxide, explosive vapor detectors), security systems (e.g., motion, vibration, glass break, door and port hole magnetic switches), an

Summary of the content on the page No. 6

SIM100 User's Manual 1.3 SIM100 Accessories Maretron offers the following accessories for the SIM100: • SH-499CSTE Smoke/Heat Detector • CO1000-S-W Carbon Monoxide (CO) Detector (Surface Mount White) • LP1000-S-W Liquid Petroleum (LP) Detector (Surface Mount White) • BHW100 Bilge High Water Detector • MD-6157-N Motion Detector • MS-1035 Magnetic Switch Rectangular (Indoor) • MS-1085-N Magnetic Switch Rectangular (Outdoor) • MS-1055-N Magnetic Switch Cylinder (Indoor/Outdo

Summary of the content on the page No. 7

® ® 2.3 Mounting the SIM100 Attach the SIM100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below. Figure 1 – Mounting the SIM100 2.4 Connecting the SIM100 ® The SIM100 requires two types of electrical connections: 1) the NMEA 2000 connection (refer to Section 2.4.1), and 2) the switch connections, which are described in Section 2.4.2. ® 2.4.1 NMEA 2000 Connection ® ® The NMEA 2000 connector can be found o

Summary of the content on the page No. 8

SIM100 User's Manual ® Figure 2 – NMEA 2000 Connector Face Views 2.4.2 Switch Connections The SIM100 switch connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the corners of the unit detaching the splash guard from the unit. On the bottom of the splash guard, you will find a label detailing the wire connection to pin number assignments, which are repeated in the table below. Pin # Signal Name Connection 1 S

Summary of the content on the page No. 9

® ® 2.4.2.1 Switch With End of Line Resistor Please refer to Figure 3 for connecting the SIM100 to a switch with an end of line resistor. This figure shows the connection of the monitored switch to switch channel 1 via the terminals named SW1A and SW1B. Connections to other switch terminals are similar. 8 K Ω end-of- Monitored switch line resistor SIM100 Screw Terminals 1 2 3 6 4 5 7 8 9 10 11 12 Figure 3 – Switch With End of Line Resistor Connection Diagram 2.4.2.2 Switc

Summary of the content on the page No. 10

SIM100 User's Manual 2.4.3 Checking Connections ® Once the NMEA 2000 connection and switch connection(s) to the SIM100 have been completed, check to see that information is being properly transmitted by observing an ® appropriate NMEA 2000 display. If you don’t see switch indicator status, refer to Section 5, “Troubleshooting”. 2.5 Configuring the SIM100 The SIM100 will transmit data over the NMEA 2000 network as it is shipped from the factory; however, it may require configurati

Summary of the content on the page No. 11

® ® 2.5.8 Advanced Configuration… Certain parameters do not normally need to be set in order for normal operation, but are included in an advanced configuration section for use in special situations. ® 2.5.9 NMEA 2000 PGN Enable/Disable ® The SIM100 is capable of transmitting NMEA 2000 messages (or PGNs) associated with monitored switch circuits. You may individually enable or disable each of these messages. You may also change the rate of transmission of each of these messages if d

Summary of the content on the page No. 12

SIM100 User's Manual A switch indicator Ensure that there is not a short circuit in the wiring for the switch. always reads “Closed” Measure the resistance between the “A” and “B” terminals for the appropriate indicator. If the switch is open, the resistance should either be an open-circuit, if the indicator is configured as “No End of Line Resistor”, or should measure 8 K Ω if the indicator is configured as “End of Line Resistor”. If the switch is closed, the resistance should be c

Summary of the content on the page No. 13

® ® 5 Technical Specifications As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron products are designed to be accurate and reliable; however, they should be used only as aids to navigation and not as a replacement for traditional navigation aids and techniques. Specifications Parameter Value Comment End of Line Resistor 8 K Ω ± 5% Included with Maretron-supplied sensors Certifications Parameter Comment ® NMEA 20

Summary of the content on the page No. 14

SIM100 User's Manual 6 Technical Support If you require technical support for Maretron products, you can reach us in any of the following ways: Telephone: 1-866-550-9100 Fax: 1-602-861-1777 E-mail: support@maretron.com World Wide Web: http://www.maretron.com Mail: Maretron, LLC Attn: Technical Support rd 9014 N. 23 Ave Suite 10 Phoenix, AZ 85021 USA Page 10 Revision 1.0

Summary of the content on the page No. 15

® ® 7 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.0 Page 11

Summary of the content on the page No. 16

SIM100 User's Manual 8 Maretron (2 Year) Limited Warranty Maretron warrants the SIM100 to be free from defects in materials and workmanship for two (2) years from the date of original purchase. If within the applicable period any such products shall be proved to Maretron’s satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s option. Purchaser's exclusive remedy and Maretron’s sole obligation hereunder, provided product is ret

Summary of the content on the page No. 17

® ® ® Appendix A – NMEA 2000 Interfacing ® SIM100 NMEA 2000 Periodic Data Transmitted PGNs PGN 127501 – Binary Switch Bank Status The SIM100 uses this PGN to transmit the state of each of the connected switch inputs Field 1: Indicator Bank Instance – This field identifies the particular switch bank to which this PGN applies. Please refer to Section 2.5.1 for instructions on how to program the value of this field. 2: Indicator #1 – This field indicates the state of the switch


Alternative user manuals
# User manual Category Download
1 Maretron M003017 User manual Switch 0
2 Maretron MS-1035 User manual Switch 1
3 Maretron VS-07.0HG User manual Switch 0
4 Maretron MS-1075 User manual Switch 1
5 Maretron MS-1085-N User manual Switch 0
6 Maretron MS-1055-N User manual Switch 0
7 Sony 4-296-436-11 (2) User manual Switch 0
8 3Com 10/100BASE-TX User manual Switch 61
9 3Com 2226-SFP User manual Switch 688
10 3Com 16985ua.bk User manual Switch 10
11 3Com 10BASE-T User manual Switch 4
12 3Com 10BASE-2 User manual Switch 1
13 3Com 1000BASE User manual Switch 6
14 3Com 2226 PLUS User manual Switch 473
15 3Com 2250-SFP User manual Switch 538