Allied Telesis AT-IFS802SPOE user manual

User manual for the device Allied Telesis AT-IFS802SPOE

Device: Allied Telesis AT-IFS802SPOE
Category: Switch
Manufacturer: Allied Telesis
Size: 7.66 MB
Added : 11/5/2013
Number of pages: 105
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Allied Telesis AT-IFS802SPOE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Allied Telesis AT-IFS802SPOE.

For your convenience

If looking through the Allied Telesis AT-IFS802SPOE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Allied Telesis AT-IFS802SPOE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Allied Telesis AT-IFS802SPOE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Allied Telesis AT-IFS802SPOE User manual - Online PDF
Advertisement
« Page 1 of 105 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Allied Telesis AT-IFS802SPOE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Allied Telesis AT-IFS802SPOE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AT-IFS802SP/POE
8x10/100TX POE Layer 2 Managed Industrial Switch
AT-IFS802SP/POE Installation and
User’s Guide
613-001691 Rev.A

Summary of the content on the page No. 2

Copyright © 2012 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc. reserves the right to make changes in specifications and other informa

Summary of the content on the page No. 3

Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy a

Summary of the content on the page No. 4

4

Summary of the content on the page No. 5

Preface This manual is the installation and management guide for the AT-IFS802SP/POE 8x10/100TX POE Layer 2 Managed Industrial Switch. The instructions in this guide explain how to install the switch, start a management session, and use the CLI and web management interfaces. Allied Telesis Contact Information If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesi

Summary of the content on the page No. 6

Preface 6

Summary of the content on the page No. 7

AT-IFS802SP/POE(W)-80 User Manual 3 Content Chapter 1 Introduction .........................................................................6 1.1 Hardware Features ....................................................................................................................6 1.2 Software Features .......................................................................................................................8 1.3 Package Contents ..................................................

Summary of the content on the page No. 8

4 AT-IFS802SP/POE(W)-80 User Manual 6.9 Fault Relay Alarm ........................................................................................................................36 6.10 SNTP Configuration ................................................................................................................36 6.11 IP Security ..................................................................................................................................39 6.12 User Authentication ..

Summary of the content on the page No. 9

AT-IFS802SP/POE(W)-80 User Manual 5 System Commands Set......................................................................................................................79 Port Commands Set ..........................................................................................................................81 Trunk Commands Set ........................................................................................................................83 VLAN Commands Set .....................

Summary of the content on the page No. 10

6 AT-IFS802SP/POE(W)-80 User Manual Chapter 1 Introduction The 8 10/100TX + 2 10/100/1000T/Mini-GBIC Combo with 8 PoE Injectors Managed Industrial Switch is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. Using fiber por t can extend the connection distance that incr eases the netw ork elasticity and perf ormance . Besides, the industrial switch provides the PoE function for kinds of Powered Devices to receive power as

Summary of the content on the page No. 11

AT-IFS802SP/POE(W)-80 User Manual 7 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E cable EIA/TIA-568 100-ohm (100m) 100Base-TX: 2-pair UTP/STP Cat. 5/ 5E cable Network Cable EIA/TIA-568 100-ohm (100m) 1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E cable EIA/TIA-568 100-ohm (100m) Distance: Multi mode: 0 to 5 km, 1300 nm (50/125 μm, 800 MHz*km) 0 to 4 km, 1300 nm (62.5/125 μm, 500 MHz*km) Single mode: 0 to 40 km, 1310 nm (9/125 μm, 3.5 PS/(nm*km)) 0 to 80 km, 1550 nm (9/125 μm, 19 PS/(nm*km)) Optical Fiber Mi

Summary of the content on the page No. 12

8 AT-IFS802SP/POE(W)-80 User Manual FCC Class A, CE EN61000-4-2, CE EN61000-4-3, CE EN-61000-4-4, CE EN61000-4-5, EMI CE EN61000-4-6, CE EN61000-4-8, CE EN61000-4-11, CE EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4 Safety UL, cUL, CE/EN60950-1 Stability Testing IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) 1.2 Software Features Management SNMP v1 v2c, v3/ Web/Telnet/CLI RFC 1215 Trap, RFC1213 MIBII, RFC 1157 SNMP MIB, RFC 1493 Bridge MIB, SNMP MIB RFC 2674 VLAN

Summary of the content on the page No. 13

AT-IFS802SP/POE(W)-80 User Manual 9 Login Security Supports IEEE802.1X Authentication/RADIUS Suppor t ingr ess pack et filter and egr ess pack et limit The egress rate control supports all of packet type and the limit rates are 100K~102400Kbps(10/100), 100K~256000Kbps(1000) Bandwidth Ingr ess filter pack et type combination rules ar e Br oadcast/Multicast/Unkno wn Control Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all of pack et. The pack et filter rate can be se

Summary of the content on the page No. 14

10 AT-IFS802SP/POE(W)-80 User Manual Chapter 2 Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. 2.1 Physical Dimension 8 10/100TX w/ X-Ring Managed Industrial Switch dimension (W x D x H) is 72mm x 105mm x 152mm 2.2 Front Panel The Front Panel of the 8 10/100TX w/ X-Ring Managed Industrial Switch is shown as below: Front Panel of the industrial switch

Summary of the content on the page No. 15

AT-IFS802SP/POE(W)-80 User Manual 11 2.3 Bottom View The bottom panel of the 8 10/100TX w/ X-Ring Managed Industrial Switch has one terminal block connector of two DC power inputs and one fault alarm. Bottom Panel of the industrial switch

Summary of the content on the page No. 16

12 AT-IFS802SP/POE(W)-80 User Manual 2.4 LED Indicators The diagnostic LEDs that provide real-time information of system and optional status are located on the front panel of the industrial switch. The following table provides the description of the LED status and their meanings for the switch. LED Color Status Meaning On The switch unit is power on PWR Green Off No power On The industrial switch is the master of X-Ring group R.M. Green Off The industrial switch is not a ring master in X-Rin

Summary of the content on the page No. 17

AT-IFS802SP/POE(W)-80 User Manual 13 Chapter 3 Hardware Installation In this paragraph, we will describe how to install the 8 10/100TX w/ X-Ring Managed Industrial Switch and the installation points attended to it. 3.1 Installation Steps 1. Unpack the Industrial switch 2. Check if the DIN-Rail is screwed on the Industrial switch or not. If the DIN-Rail is not screwed on the Industrial switch, please refer to DIN-Rail Mounting section for DIN-Rail installation. If users want to wall mount th

Summary of the content on the page No. 18

14 AT-IFS802SP/POE(W)-80 User Manual 3.2 DIN-Rail Mounting The DIN-Rail is screwed on the industrial switch when out of factory. If the DIN-Rail is not screwed on the industrial switch, please see the following pictures to screw the DIN-Rail on the switch. Follow the steps below to hang the industrial switch. 1. First, insert the top of DIN-Rail into the track. 2. Then, lightly push the DIN-Rail into the track. 3. Check if the DIN-Rail is tightened on the track or not. 4. To remove the

Summary of the content on the page No. 19

AT-IFS802SP/POE(W)-80 User Manual 15 3.3 Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3. Use the screws to screw the wall mount plate on the industrial switch. 4. Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall. 5. To remo

Summary of the content on the page No. 20

16 AT-IFS802SP/POE(W)-80 User Manual 3.4 Wiring the Power Inputs Please follow the steps below to insert the power wire. 1. Insert AC or DC power wires into the contacts 1 and 2 for power 1, or 5 and 6 for power. 2. Tighten the wire-clamp screws for preventing the wires from loosing. The wire gauge for the terminal block should be in the range between 12 ~ 24 [note] AWG.


Alternative user manuals
# User manual Category Download
1 Allied Telesis 24i User manual Switch 24
2 Allied Telesis AT -8000S/24 User manual Switch 182
3 Allied Telesis 8100S User manual Switch 28
4 Allied Telesis 4000 Series User manual Switch 9
5 Allied Telesis 48W User manual Switch 5
6 Allied Telesis AT -8000S/48 User manual Switch 33
7 Allied Telesis 86241-06 User manual Switch 0
8 Allied Telesis 613-001480 User manual Switch 4
9 Allied Telesis 8PS User manual Switch 1
10 Allied Telesis AT-8100L/8POE User manual Switch 3
11 Allied Telesis AT-8100S/24F-LC User manual Switch 0
12 Allied Telesis AT-8000GS/48 User manual Switch 34
13 Allied Telesis AT-8100S/16F8-SC User manual Switch 3
14 Allied Telesis AT-8100S/16F8-LC User manual Switch 0
15 Allied Telesis AT-8100S/48 User manual Switch 6
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4