Allied Telesis EPSR AT-8948 user manual

User manual for the device Allied Telesis EPSR AT-8948

Device: Allied Telesis EPSR AT-8948
Category: Switch
Manufacturer: Allied Telesis
Size: 0.48 MB
Added : 2/28/2013
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Allied Telesis EPSR AT-8948. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Allied Telesis EPSR AT-8948.

For your convenience

If looking through the Allied Telesis EPSR AT-8948 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Allied Telesis EPSR AT-8948 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Allied Telesis EPSR AT-8948 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Allied Telesis EPSR AT-8948 User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Allied Telesis EPSR AT-8948 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Allied Telesis EPSR AT-8948. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TM
AlliedWare OS
How To | Configure EPSR (Ethernet Protection Switching
Ring) to Protect a Ring from Loops
Introduction
Putting a ring of Ethernet switches at the core of a network is a simple way to increase the
network’s resilience—such a network is no longer susceptible to a single point of failure.
However, the ring must be protected from Layer 2 loops. Traditionally, STP-based
technologies are used to protect rings, but they are relatively slow to recover from link
failure. This can cr

Summary of the content on the page No. 2

Which products and software versions does it apply to? � "Example 3: EPSR and RSTP" on page 17 � "Example 4: EPSR with Nested VLANs" on page 20 � "Example 5: EPSR with management stacking" on page 23 � "Example 6: EPSR with an iMAP" on page 26 Next, it discusses important implementation details in the following sections: � "Classifiers and Hardware Filters" on page 29 � "Ports and Recovery Times" on page 30 � "IGMP Snooping and Recovery Times" on page 31 � "Health Message Priority" on page

Summary of the content on the page No. 3

2 _ 1 N _ A N L V N A L A a V L t V a a l t D o a r t D n o C How EPSR Works How EPSR Works EPSR operates on physical rings of switches (note, not on meshed networks). When all nodes and links in the ring EPSR Components are up, EPSR prevents a loop by blocking data transmission EPSR domain: across one port. When a node or link fails, EPSR detects the failure rapidly and responds by unblocking the blocked A protection scheme for an port so that data can flow around the ring. Ethernet

Summary of the content on the page No. 4

How EPSR Works Establishing a Ring Once you have configured EPSR on the switches, the following steps complete the EPSR ring: 1. The master node creates an EPSR Health message and sends it out the primary port. This increments the master node’s Transmit: Health counter in the show epsr count command. 2. The first transit node receives the Health message on one of its two ring ports and, using a hardware filter, sends the message out its other ring port. Note that transit nodes never generate

Summary of the content on the page No. 5

How EPSR Works Detecting a Fault EPSR uses a fault detection scheme that alerts the ring when a break occurs, instead of using a spanning tree- Master Node States like calculation to determine the best path. The ring then automatically heals itself by sending traffic over a Complete: protected reverse path. The state when there are no link or node failures on the ring. EPSR uses the following two methods to detect when a transit node or a link goes down: Failed: The state when there is a li

Summary of the content on the page No. 6

How EPSR Works new configuration, the nodes (master and transit) re-learn their layer 2 addresses. During this period, the master node continues to send Health messages over the control VLAN. This situation continues until the faulty link or node is repaired. For a multidomain ring, this process occurs separately for each domain within the ring. The following figure shows the flow of control frames when a link breaks. Control VLAN is forwarding Control VLAN is forwarding Data VLANs move from b

Summary of the content on the page No. 7

How EPSR Works Restoring Normal Operation Master Node Once the fault has been fixed, the master node’s Health messages traverse the whole ring and arrive at the master node’s secondary port. The master node then restores normal conditions by: 1. declaring the ring to be in a state of Complete 2. blocking its secondary port for data VLAN traffic (but not for the control VLAN) 3. flushing its forwarding database for its two ring ports 4. sending a Ring-Up-Flush-FDB message from its primary port,

Summary of the content on the page No. 8

How To Configure EPSR How To Configure EPSR This section first outlines, step-by-step, how to configure EPSR. Then it discusses changing the settings for the control VLAN, if you need to do this after initial configuration. Configuring EPSR 1. Connect your switches into a ring EPSR does not in itself limit the number of nodes that can exist on any given ring. Each switch can participate in up to 16 rings. If you already have a ring in a live network, disconnect the cable between any two of t

Summary of the content on the page No. 9

How To Configure EPSR iii. Remove the ring ports from the default VLAN If you leave all the ring ports in the default VLAN (vlan1), they will create a loop, unless vlan1 is part of the EPSR domain. To avoid loops, you need to do one of the following: � make vlan1 a data VLAN, or � remove the ring ports from vlan1, or � remove at least one of the ring ports from vlan1 on at least one of the switches. We do not recommend this option, because the action you have taken is less obvious when mainta

Summary of the content on the page No. 10

How To Configure EPSR Modifying the Control VLAN You cannot modify the control VLAN while EPSR is enabled. If you try to remove or add ports to the control VLAN, the switch generates an error message as follows: Manager> delete vlan=1000 port=1 Error (3089409): VLAN 1000 is a control VLAN in EPSR and cannot be modified Disable the EPSR domain and then make the required changes. Note that disabling EPSR will create a loop, so is not recommended on a network with live data. Of course, in a live

Summary of the content on the page No. 11

Example 1: A Basic Ring Example 1: A Basic Ring This example builds a simple 3-switch ring with one data VLAN, as shown in the following diagram. Control packets are transmitted around the ring on vlan1000 and data packets on vlan2. End User Ports port 1: primary port 2: secondary P S Master Node (A) port 1: ring port 1: ring End User Ports End User Ports port 2: ring port 2: ring Transit Transit Node Node (B) (C) epsr-example-basic-ring Configure the Master Node (A) 1. Create the contro

Summary of the content on the page No. 12

Example 1: A Basic Ring 5. Remove the ring ports from the default VLAN delete vlan=1 port=1-2 6. Create the EPSR domain This step creates the domain, specifying that this switch is the master node. It also specifies which VLAN is the control VLAN and which port is the primary port. create epsr=test mode=master controlvlan=vlan1000 primaryport=1 7. Add the data VLAN to the domain add epsr=test datavlan=vlan2 8. Enable EPSR enable epsr=test Configure the Transit Nodes (B and C) Each of the trans

Summary of the content on the page No. 13

Example 1: A Basic Ring 6. Create the EPSR domain This step creates the domain, specifying that this switch is the transit node. It also specifies which VLAN is the control VLAN. create epsr=test mode=transit controlvlan=vlan1000 7. Add the data VLAN to the domain add epsr=test datavlan=vlan2 8. Enable EPSR enable epsr=test Page 13 | AlliedWare™ OS How To Note: EPSR

Summary of the content on the page No. 14

Example 2: A Double Ring Example 2: A Double Ring This example adds to the previous ring by making two domains, as shown in the following diagram. Master Master Node Node port 1: port 4: (A) (C) primary primary port 2: port 5: secondary secondary port 1 port 4 Domain 1 Domain 2 control VLAN: 1000 control VLAN: 40 data VLAN: 2 data VLAN: 50 port 2 port 5 Transit port 1 port 4 Node (E) port 2 port 5 Transit Transit Node Node (B) (D) epsr-example-double-ring 1. Configure the master node (switc

Summary of the content on the page No. 15

Example 2: A Double Ring 2. Configure the transit node (switch B) that belongs just to domain 1 This transit node is the same as in the previous example (except that the domain has been renamed). create vlan=vlan1000 vid=1000 add vlan=1000 port=1-2 frame=tagged create vlan=vlan2 vid=2 add vlan=2 port=1-2 frame=tagged delete vlan=1 port=1-2 create epsr=domain1 mode=transit controlvlan=vlan1000 add epsr=domain1 datavlan=vlan2 enable epsr=domain1 3. Configure the master node (switch C) for domai

Summary of the content on the page No. 16

Example 2: A Double Ring Configure EPSR: create epsr=domain2 mode=transit controlvlan=vlan40 add epsr=domain2 datavlan=vlan50 enable epsr=domain2 5. Configure the transit node (switch E) that belongs to both domains Two separate EPSR domains are configured on this switch. Configure the control VLAN for domain 1: create vlan=vlan1000 vid=1000 add vlan=1000 port=1-2 frame=tagged Configure the control VLAN for domain 2: create vlan=vlan40 vid=40 add vlan=40 port=4-5 frame=tagged Configure the data

Summary of the content on the page No. 17

Example 3: EPSR and RSTP Example 3: EPSR and RSTP This example uses EPSR to protect one ring and RSTP to protect another overlapping ring. RSTP Master Switch Node (C) port 1: (A) port 10 primary port 2: port 11 secondary port 1 port 10 Domain 1 RSTP: control VLAN: 1000 STP VLAN: 10 data VLAN: 2 port 2 port 11 Switch port 1 port 10 (E) port 2 port 11 RSTP Transit Switch Node (D) (B) epsr-example-rstp 1. Configure the master node (switch A) for the EPSR domain The master node is the same as in

Summary of the content on the page No. 18

Example 3: EPSR and RSTP 2. Configure the transit node (switch B) that belongs just to the EPSR domain This transit node (B) is the same as in the previous example. create vlan=vlan1000 vid=1000 add vlan=1000 port=1-2 frame=tagged create vlan=vlan2 vid=2 add vlan=2 port=1-2 frame=tagged delete vlan=1 port=1-2 create epsr=domain1 mode=transit controlvlan=vlan1000 add epsr=domain1 datavlan=vlan2 enable epsr=domain1 3. Configure the switches that belong to the RSTP instance (switches C and D) Switc

Summary of the content on the page No. 19

Example 3: EPSR and RSTP 4. Configure switch E for EPSR and RSTP Configure the control VLAN for EPSR: create vlan=vlan1000 vid=1000 add vlan=1000 port=1-2 frame=tagged Configure the data VLAN for EPSR: create vlan=vlan2 vid=2 add vlan=2 port=1-2 frame=tagged Remove the ring ports from the default VLAN: delete vlan=1 port=1-2 Configure EPSR: create epsr=domain1 mode=transit controlvlan=vlan1000 add epsr=domain1 datavlan=vlan2 enable epsr=domain1 Configure the STP VLAN: create vlan=vlan10 vid=10 a

Summary of the content on the page No. 20

Example 4: EPSR with Nested VLANs Example 4: EPSR with Nested VLANs In this example: � client switches A and C are in the same end-user VLAN (vlan20) � client switches B and D are in the same end-user VLAN (vlan200) � traffic for vlan20 and vlan200 is nested inside vlan50 for transmission around the core � vlan50 is the data VLAN for the EPSR domain � vlan100 is the control VLAN for the EPSR domain Client Client Switch Switch (E) (H) port 20 port 10 port 22 port 22 port 2: port 2 secondary Mast


Alternative user manuals
# User manual Category Download
1 Allied Telesis 24i User manual Switch 24
2 Allied Telesis AT -8000S/24 User manual Switch 182
3 Allied Telesis 8100S User manual Switch 28
4 Allied Telesis 4000 Series User manual Switch 9
5 Allied Telesis 48W User manual Switch 5
6 Allied Telesis AT -8000S/48 User manual Switch 33
7 Allied Telesis 86241-06 User manual Switch 0
8 Allied Telesis 613-001480 User manual Switch 4
9 Allied Telesis 8PS User manual Switch 1
10 Allied Telesis AT-8100L/8POE User manual Switch 3
11 Allied Telesis AT-8100S/24F-LC User manual Switch 0
12 Allied Telesis AT-8000GS/48 User manual Switch 34
13 Allied Telesis AT-8100S/16F8-SC User manual Switch 3
14 Allied Telesis AT-8100S/16F8-LC User manual Switch 0
15 Allied Telesis AT-8100S/48 User manual Switch 6
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4