Transition Networks SISTF10XX-170-LR(T) user manual

User manual for the device Transition Networks SISTF10XX-170-LR(T)

Device: Transition Networks SISTF10XX-170-LR(T)
Category: Switch
Manufacturer: Transition Networks
Size: 0.19 MB
Added : 9/1/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Transition Networks SISTF10XX-170-LR(T). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Transition Networks SISTF10XX-170-LR(T).

For your convenience

If looking through the Transition Networks SISTF10XX-170-LR(T) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Transition Networks SISTF10XX-170-LR(T) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Transition Networks SISTF10XX-170-LR(T) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Transition Networks SISTF10XX-170-LR(T) User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Transition Networks SISTF10XX-170-LR(T) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Transition Networks SISTF10XX-170-LR(T). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
SISTF10xx-140-LR(T)
SISTF10xx-160-LR(T)
SISTF10xx-170-LR(T)
Stand-Alone Ethernet Switch
• 10Base-T / 100Base-TX to 100Base-FX
 Extended Temperature
 Hazardous Environment
Transition Networks industrial Ethernet switch
connects 10Base-T / 100Base-TX twisted-pair
copper cable to 100Base-FX fiber-optic cable. It is
designed for harsh industrial environments and is
also available in models that operate in either
SISTF10xx-140-LR(T)
standard or extended temperature ranges.
The SI

Summary of the content on the page No. 2

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) SISTF10xx-160-LR(T) SISTF10xx-170-LR(T) The SISTF10xx-160-LR(T) model includes six (6) copper RJ-45 ports and two (2) The SISTF10xx-170-LR(T) model includes seven (7) copper RJ-45 ports and one (1) duplex fiber-optic ports. duplex fiber-optic port. Part Number Ports 1 - 6: Copper Ports 7 & 8: Duplex Fiber-Optic Part Number Ports 1 - 7: Copper Port 8: Duplex Fiber-Optic 10Base-T/100Base-TX 100Base-FX Duplex 10Base-T/100Base-TX 100Base-FX Duplex Sta

Summary of the content on the page No. 3

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Installation Installation -- Continued CAUTION: Disconnect the Ethernet switch from the DC power source DIN-Rail Mount BEFORE installing and/or wiring the device. The Ethernet switch includes an aluminum DIN-Rail mounting plate attached to the device’s back panel. To mount the device onto a DIN-Rail: Install the Fiber Cable 1. Insert the top of the DIN-Rail into the upper slot of the mounting plate. The stiff metal spring should be positioned behi

Summary of the content on the page No. 4

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Installation -- Continued Installation -- Continued Set the Port Alarm Switches Install the Port Alarm Device The port alarm feature is used to determine faults at the copper or fiber ports. A user-supplied port alarm device can be connected to the Ethernet switch to The dip switches are located on the top panel of the device. Use a small flat alert the user whenever a power fault or a port fault occurs. At least one port blade screwdriver or a sim

Summary of the content on the page No. 5

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Installation -- Continued Operation Power the Ethernet switch Features Auto-Negotiation This device is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. With the Auto-Negotiation feature, the Ethernet switch automatically configures itself to achieve the best possible mode of operation over the WARNING: EXPLOSION HAZARD - Do not disconnect equipment copper link. The device broadcasts its speed (10 Mb/s

Summary of the content on the page No. 6

100BASE-FX 100BASE-FX 100BASE-FX 10/100BASE-TX 10/100BASE-TX PWR 1 PWR 1 TX TX PWR 1 PWR 2 PWR 2 PWR 2 FAULT FAULT FAULT RX RX 100M 100M TX TX RX RX 100M 100M SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Operation -- Continued Operation -- Continued Status LEDs Use the status LEDs to monitor the Ethernet switch operation in the network. Power and Fault LEDs SISTF10xx-140-LR(T) SISTF10xx-160-LR(T) SISTF10xx-170-LR(T) The three LEDs near the top indicate the power and fault status: PWR1 (amber)

Summary of the content on the page No. 7

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Cable Specifications Cable Specifications -- Continued The physical characteristics must meet or exceed IEEE 802.3™ specifications. Extended Temperature Models Fiber Cable SISTF1011-140-LRT SISTF1011-160-LRT Bit Error Rate: <10-9 SISTF1011-170-LRT 1300 nm multimode Single mode fiber (recommended): 9 µm Fiber Optic Transmitter Power: min: -20.0 dBm max: -14.0 dBm Multimode fiber (recommended): 62.5/125 µm Fiber Optic Receiver Sensitivity: min: -

Summary of the content on the page No. 8

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Cable Specifications -- Continued Technical Specifications Copper Cable For use with Transition Networks Model Ethernet switch or equivalent Standards: IEEE 802.3™, 802.3u™; 802.3x™ Category 5: (minimum requirement) Gauge / Attenuation: 24 to 22 AWG / 22.0 dB per 100m @ 100 MHz Data Rate: 10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber)  Straight-through OR crossover cable may be used. Processing Type: Store and Forward  Shielded twisted-pair (STP)

Summary of the content on the page No. 9

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Technical Specification -- Continued Troubleshooting If the device fails, isolate and correct the fault by determining the answers to the This device has been evaluated as EEx nC IIC T4 equipment under DEMKO following questions and then taking the indicated action: Certificate No. 03 ATEX 0324537U. Each module is suitable for use in Zone 2 Explosive Atmospheres. The device must be installed in a minimum IP 54 enclosure as defined in IEC 60529 and EN

Summary of the content on the page No. 10

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T) Troubleshooting -- Continued Contact Us 5. Is a 100M LED (near the fiber links) flashing? Technical Support NO Technical support is available 24 hours a day  If there is activity on the corresponding fiber port, disconnect and US and Canada: 1-800-260-1312 reconnect the fiber cable to restart the initialization process. International: 00-1-952-941-7600  If there is no activity on the corresponding fiber port, contact Tech Transition Now Support: 80

Summary of the content on the page No. 11

Compliance Information UL Listed; C-UL Listed (Canada) NOTE: The following part numbers are UL listed: SISTF1013-140-LR, SISTF1013-140-LRT, SISTF1014-140-LR, SISTF1014-140-LRT, SISTF1013-160-LR, SISTF1013-160-LRT, SISTF1014- 160-LR, SISTF1014-160-LRT, SISTF1013-170-LR, SISTF1013-170-LRT, SISTF1014-170-LR, SISTF1014-170-LRT. CISPR22/EN55022 Class A; CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the


Alternative user manuals
# User manual Category Download
1 Transition Networks CSEFE10XX-10X User manual Switch 1
2 Transition Networks LAN MASTER E-TBT-HB-0804 User manual Switch 1
3 Transition Networks LAN MASTER 33022.B User manual Switch 2
4 Transition Networks MIL-SM8002TG User manual Switch 1
5 Transition Networks E-MUX-SA05 User manual Switch 0
6 Transition Networks E-TBT-HB-0802 User manual Switch 0
7 Transition Networks SBFTF1011-120 User manual Switch 0
8 Transition Networks MIL-S8TA User manual Switch 10
9 Transition Networks Milan MIL-SM2401MAF User manual Switch 0
10 Transition Networks MIL-SM808GPXX User manual Switch 0
11 Transition Networks SBFTF1014-120 User manual Switch 2
12 Transition Networks E-PSW-TX-02 User manual Switch 0
13 Transition Networks MIL-SW8T1GPA User manual Switch 1
14 Transition Networks SBFTF1013-120 User manual Switch 1
15 Transition Networks SBFTF1016-120 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4