Transition Networks SISTM10XX-162-LR user manual

User manual for the device Transition Networks SISTM10XX-162-LR

Device: Transition Networks SISTM10XX-162-LR
Category: Switch
Manufacturer: Transition Networks
Size: 1.02 MB
Added : 9/1/2014
Number of pages: 57
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Transition Networks SISTM10XX-162-LR. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Transition Networks SISTM10XX-162-LR.

For your convenience

If looking through the Transition Networks SISTM10XX-162-LR user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Transition Networks SISTM10XX-162-LR on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Transition Networks SISTM10XX-162-LR to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Transition Networks SISTM10XX-162-LR User manual - Online PDF
Advertisement
« Page 1 of 57 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Transition Networks SISTM10XX-162-LR but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Transition Networks SISTM10XX-162-LR. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1








SISTM10xx-162-LR(T)
(6) 10/100Base-TX + (2) 100Base-FX
Industrial Managed Switch

Installation Manual



Rev. 1

25-October-2007

Summary of the content on the page No. 2

Notice This manual contents are based on the below table listing software kernel version, hardware version, and firmware version. If the switch functions have any different from the manual contents description, please contact Transition Networks for more information. Firmware Version v1.02 Kernel Version v3.22 Hardware Version A5.00 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules.

Summary of the content on the page No. 3

Contents Notice........................................................................................................................................... 1 FCC Warning ............................................................................................................................... 1 CE Mark Warning ........................................................................................................................ 1 Introduction .........................................

Summary of the content on the page No. 4

Port status.................................................................................................................................. 17 Single Port Information ........................................................................................................ 18 Port Statistics............................................................................................................................. 18 Port Control..............................................................

Summary of the content on the page No. 5

Save Configuration .................................................................................................................... 44 Rate Control............................................................................................................................... 44 System Log................................................................................................................................ 45 System Log Configuration...............................................

Summary of the content on the page No. 6

Introduction The SISTM10xx-162-LRx Managed Industrial Switch is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. The switch can be easily managed through the Web GUI. By using fiber port can extend the connection distance that increases the network elasticity and performance. It also provides the X-Ring function that can prevent the network connection failure. Features • Conform to IEEE 802.3 10Base-T, 802.3u 100Base-TX/1

Summary of the content on the page No. 7

Package Contents Please refer to the package content list below to verify them against the checklist. • SISTM10xx-162-LRx Managed Industrial Switch • DC Jack 2.0/150mm RoHS • User manual CD • DIN-Rail Bracket (attached on the switch) • One wall mount plate and six screws SISTM10xx-162-LRx DC Jack 2.0/150mm RoHS User Manual CD Wall Mount Plate Screws DIN-Rail Bracket (installed

Summary of the content on the page No. 8

Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. Physical Dimension 54mm (w) x 135mm (h) x 105mm (d) Front Panel The Front Panel of the SISTM10xx-162-LRx Managed Industrial Switch is shown below: Reset Button The reset button provides user a quick and easy way to restart and set the configuration back to default value. • Restart: press the button for 2 seconds a

Summary of the content on the page No. 9

set all configurations back to default setting Bottom View The bottom view of the switch is shown below: Grounding Screw 6-position terminal block Primary power input terminals (2) Secondary power input Contact relay output terminals (2) DIP-switch The switch provides the 9 DIP-switch for configuring the relay alarm operation mode and the master ring operation mode. The default value of Dipswitch is OFF. DIP Switch No Status Description OFF Disable port 1

Summary of the content on the page No. 10

OFF Disable port Alarm 5 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable port Alarm 6 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable port Alarm 7 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable port Alarm 8 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable the ring master function 9 Enable the switch as the ring mas

Summary of the content on the page No. 11

Off No power inputs Power failure or UTP port failure or Fiber port Yellow failure Fault No Power failure or UTP port failure or Fiber port Off failure occurs The industrial switch is the master of X-Ring Green group R.M. (Ring Master) The industrial switch is not a ring master in X- Off Ring group Green The port is linking LNK/ACT The port is transmitting or receiving packets Blinks (Fiber port) from the TX device Off No device attached Yellow The port is operating in ful

Summary of the content on the page No. 12

All ports on this industrial switch support automatic MDI/MDI-X operation, user can use straight- through cables (See figure below) for all network connections to PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below shows the 10BASE- T/100BASE-TX MDI and MDI-X port pin outs. Pin MDI-X Signal Name MDI Signal Name 1 Receive Da

Summary of the content on the page No. 13

ATTENTION This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam. Cabling • Using four twisted-pair, Category 5 cabling for RJ-45 port connection. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long. • Fiber segment using single-mode connector type must use 9/125 um single-mode fiber cable. User can connect two devices in the distance up to 30 Kilometers. • Fiber segment using

Summary of the content on the page No. 14

Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows. By inserting the wires and set the DIP switch at “ON” status, it will detect the fault status which the power is failure or port link failure and form an open circuit. And, application example for the fault alarm contact as below: 1A@24V Insert the wires into the fault alarm contact [NOTE] The wire range of terminal block is from 12~ 24 AWG. Fault Ala

Summary of the content on the page No. 15

Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the industrial switch when out of factory. 1. First, insert the top of DIN-Rail into the track. 2. Then, lightly push the DIN-Rail into the track. 10

Summary of the content on the page No. 16

3. Check the DIN-Rail is tightly on the track. 4. To remove the industrial switch from the track, reverse steps above. Wall Mount Plate Mounting Follow the below steps to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3. Use the screws to screw the wall mount plate on the industrial switch. 4. Use the hook holes

Summary of the content on the page No. 17

Hardware Installation Installation Steps 1. Unpacking the Industrial switch 2. Check the DIN-Rail is screwed on the Industrial switch. If the DIN-Rail is not screwed on the Industrial switch. Please refer to DIN-Rail Mounting section for DIN-Rail installation. If user want to wall mount the Industrial switch, then please refer to Wall Mount Plate Mounting section for wall mount plate installation. 3. To hang the Industrial switch on the DIN-Rail track or wall, please refer to the

Summary of the content on the page No. 18

Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch is as below: 13

Summary of the content on the page No. 19

X-Ring Application The industrial switch supports the X-Ring protocol that can help the network system to recovery from network connection failure within 300ms or less, and make the network system more reliable. The X- Ring algorithm is like as spanning tree protocol (STP) algorithm but it has faster recovery time than STP. The following figure is a sample X-Ring application. 14

Summary of the content on the page No. 20

Coupling Ring Application In the network, it may have more than one X-Ring group. By using the coupling ring function can connect each X-Ring for the redundant backup. It can ensure the transmissions between two ring groups will no failure. The following figure is a sample of coupling ring application. Dual Homing Application Dual Homing function is to prevent a lost connection between X-Ring group and upper level/core switch. Assign two ports to be the Dual Homing port that is


Alternative user manuals
# User manual Category Download
1 Transition Networks CSEFE10XX-10X User manual Switch 1
2 Transition Networks LAN MASTER E-TBT-HB-0804 User manual Switch 1
3 Transition Networks LAN MASTER 33022.B User manual Switch 2
4 Transition Networks MIL-SM8002TG User manual Switch 1
5 Transition Networks E-MUX-SA05 User manual Switch 0
6 Transition Networks E-TBT-HB-0802 User manual Switch 0
7 Transition Networks SBFTF1011-120 User manual Switch 0
8 Transition Networks MIL-S8TA User manual Switch 10
9 Transition Networks Milan MIL-SM2401MAF User manual Switch 0
10 Transition Networks MIL-SM808GPXX User manual Switch 0
11 Transition Networks SBFTF1014-120 User manual Switch 2
12 Transition Networks E-PSW-TX-02 User manual Switch 0
13 Transition Networks MIL-SW8T1GPA User manual Switch 1
14 Transition Networks SBFTF1013-120 User manual Switch 1
15 Transition Networks SBFTF1016-120 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4