Xantrex Technology Xantrex AC to DC Converter XADC user manual

User manual for the device Xantrex Technology Xantrex AC to DC Converter XADC

Device: Xantrex Technology Xantrex AC to DC Converter XADC
Category: TV Converter Box
Manufacturer: Xantrex Technology
Size: 1.21 MB
Added : 8/2/2014
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Xantrex Technology Xantrex AC to DC Converter XADC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Xantrex Technology Xantrex AC to DC Converter XADC.

For your convenience

If looking through the Xantrex Technology Xantrex AC to DC Converter XADC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Xantrex Technology Xantrex AC to DC Converter XADC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Xantrex Technology Xantrex AC to DC Converter XADC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Xantrex Technology Xantrex AC to DC Converter XADC User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Xantrex Technology Xantrex AC to DC Converter XADC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Xantrex Technology Xantrex AC to DC Converter XADC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

XADC
Xantrex AC to DC Converter
975-0301-01-01 Revision E
Installation Instructions
About These Installation Instructions- - - - - - - - - - - - - - - - - - - - - - 2
Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
Main Components- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
AC/DC Distribution Panel - - - - - - - - - - - - - - - - - - - - - -

Summary of the content on the page No. 2

Xantrex AC to DC Converter About These Installation Instructions Purpose The purpose of these Installation Instructions is to provide explanations and procedures for installing the Xantrex AC to DC Converter (XADC). The Installation Instructions provide safety guidelines and procedures for installing the XADC. Audience These Installation Instructions are intended for qualified installers, who need to be certified technicians or electricians. Conventions Used The following conventions are use

Summary of the content on the page No. 3

Installation Instructions Important Safety Instructions WARNING: Limitations on Use The Xantrex AC to DC Converter is not intended for use in connection with life support systems or other medical equipment or devices. WARNING This section contains important safety and operating instructions. Read and keep these Installation Instructions for future reference. 1. Before installing and using the XADC, read all instructions and cautionary markings on the XADC, the batteries, and all appropriate s

Summary of the content on the page No. 4

Xantrex AC to DC Converter Explosive Gas Precautions WARNING: Explosion hazard 1. Working in the vicinity of batteries may be dangerous. Batteries generate explosive gases during normal operation, therefore, you must read this guide and follow the instructions exactly before installing or using your XADC. 2. This equipment contains components which tend to produce arcs or sparks. To prevent fire or explosion, do not install the XADC in compartments containing batteries or flammable materials

Summary of the content on the page No. 5

Installation Instructions 12. Use the XADC for charging a lead-acid battery only. Do not use the XADC to charge nickel-cadmium or dry-cell batteries commonly used with home appliances and electronic equipment. These batteries may burst and cause injury to persons and damage to property. 13. Never attempt to charge a frozen battery. Charging a battery when its temperature is below 32 °F (0 °C) is inefficient and ineffective. If possible, warm the battery above 32 °F (0 °C) before charging. F

Summary of the content on the page No. 6

Xantrex AC to DC Converter Installation Main Components Figure 1 and Figure 2 show the main components of the XADC. 4 3 2 1 5 Figure 1 XADC External Components Item Description 1 AC wiring compartment 2 Intake and outflow vents (do not obstruct) 3 DC wiring compartment 4 Ground connection (2 possible connection locations) 5 Mounting flanges 6 975-0301-01-01

Summary of the content on the page No. 7

Installation Instructions 5 4 3 6 2 7 POS NEG 1 (+) (-) 8 9 Figure 2 XADC Internal Components Item Description 1 AC wiring compartment hole 2 Black AC line cable 3 White AC neutral cable 4 Green AC ground cable 5 Grommet (supplied) 6 Strain relief (not supplied) 7 DC wiring compartment hole ½ in. - 3/8 in. trade size (with ¾ in. knockout) 8DC fuses 9 DC positive (+) and negative (-) connection lugs AC/DC Distribution Panel The XADC may be pre-installed with an AC/DC Distribution Panel. The pan

Summary of the content on the page No. 8

Xantrex AC to DC Converter 6 1 5 7 2 8 3 9 4 Figure 3 AC/DC Distribution Panel Components Item Description 1 DC fuse/AC breaker access panel (swings open with thumb latch) 2 Removable DC fuse access panel with DC circuit designation label. 3 Removable AC/DC Distribution Panel faceplate (service technician only) 4 Removable faceplate for XADC converter (service technician only) 5 Screw for removing panel faceplate (service technician only) 6 AC breakers (not included) 7 Screw for removing DC fuse

Summary of the content on the page No. 9

Installation Instructions 6 5 4 7 8 9 3 10 2 11 1 12 13 14 Figure 5 AC/DC Distribution Panel and XADC Internal Components Item Description 1 Equipment Grounding Terminal bus (front) 2 AC Neutral Terminal bus (rear) 3 AC wiring knockouts (½ in. - 3/8 in. trade size - and ¾ in. nested) (7 positions) 4 AC breakers (not included) (50 A panel shown fully populated) 5 DC branch circuit fuses (not included) maximum 20 amps per branch 6 DC positive terminal strip (11 positions) 7 DC wiring knockouts (½

Summary of the content on the page No. 10

Xantrex AC to DC Converter Installation Codes Governing installation codes vary depending on the specific location and application of the installation. It is the installer’s responsibility to ensure that all applicable installation requirements are met. Some examples include the following: • The U.S. National Electrical Code (NEC) • The Canadian Electrical Code (CEC) • The U.S. Code of Federal Regulations (CFRs) • Canadian Standards Association (CSA) and the RV Industry Association (RVIA) for

Summary of the content on the page No. 11

Installation Instructions • XADC converter faceplate and mounting hardware • Plastic bag containing two mounting tabs and related hardware, one top mounting flange and related hardware Choosing a Location The XADC and AC/DC Distribution Panel must only be installed in a location that is: Dry Do not allow water or other liquids to drop or splash on the XADC. Cool While the unit will safely operate at ambient air temperatures between 14 ºF and 86 ºF (-10 ºC and 30 ºC) and will operate de-rated

Summary of the content on the page No. 12

Xantrex AC to DC Converter Installing the XADC (stand-alone unit) Follow the procedures in the order given: 1. “Preparing to Install” 2. “Preparing the Mounting Location for the XADC” 3. “Connecting the DC Battery” 4. “Connecting the AC Input” 5. “Mounting the XADC” Preparing to Install To prepare the XADC for installation: 1. Plan your wire routing to and from the AC input breaker and the DC battery using the wire lengths recommended in Table 2 on page 24. 2. Attach the two mounting flanges to

Summary of the content on the page No. 13

Installation Instructions Preparing the Mounting Location for the XADC To prepare the XADC mounting location: 1. Place the XADC into the intended mounting position and hold it against the mounting surface. 2. Mark the positions of the four side flange mounting screws, and then remove the XADC. 3. Drill pilot holes for the mounting screws in the marked positions. Connecting the DC Battery When following the procedure, see Table 2 on page 24 for wire lengths and Table 1 on page 24 for torque v

Summary of the content on the page No. 14

Xantrex AC to DC Converter Strain relief Ground lug (option 1) DC wiring knockout Ground lug (option 2) POS NEG (+) (-) Negative DC connection lug screw Positive DC connection lug screw Figure 9 XADC DC Connections Connecting the AC Input When following the procedure, see Table 1 on page 24 for torque values. WARNING: Shock hazard Ensure that the AC disconnect or breaker is open on the AC line before attempting any installation. To connect the AC input: 1. Route AC wires through the AC wir

Summary of the content on the page No. 15

Installation Instructions Mounting the XADC To mount the XADC using the mounting plates: 1. Align the XADC with the 4 previously marked mounting positions. 2. Fasten the XADC using 4 × #6 or #8 pan head, round head or washer head screws suitable for mounting unit onto particleboard or wood. Tighten until the unit is secure to the mounting surface. Installing XADC with the AC/DC Distribution Panel Follow this procedure if you are planning to install the XADC with the optional AC/DC Distributio

Summary of the content on the page No. 16

Xantrex AC to DC Converter 4. AC breaker positions 1 and 2 have been removed from the removable faceplate on the panel. Remove extra positions from the panel by twisting the knockouts back and forth. Any knockouts that have been accidentally removed can be replaced with one of the following parts: ITE Gould QF-3 or Cutler Hammer/Bryant/Westinghouse FB-1B. 5. If you intend to mount the XADC and panel remotely, install a UL/CSA approved strain relief on both of the bottom AC and DC wiring com

Summary of the content on the page No. 17

Installation Instructions Add these two mounting tabs (from the panel hardware bag) Add this mounting flange (from the panel hardware bag) Remove this side mounting flange (keep the left or right flange and Add this mounting flange Remove this side mounting hardware for (using one of the removed mounting flange the bottom flange) side mounting flanges and the associated hardware) Figure 11 Mounting Flanges for Installation 4. Take one of the side mounting flanges that you removed in ste

Summary of the content on the page No. 18

Xantrex AC to DC Converter Preparing the Mounting Location for the XADC and Panel To prepare the XADC and panel mounting location: 1. Cut a mounting hole (12 in. × 12 1/8 in. – 305 mm × 307 mm) for the connected XADC and panel, or follow the instructions in “Preparing the Mounting Location for the XADC” on page 13 for the XADC and cut a mounting hole (12 in. × 8 in. – 305 mm × 203 mm) for the panel, or use an existing hole from a previous converter installation. 2. Place the XADC and panel i

Summary of the content on the page No. 19

Installation Instructions 3. Connect the incoming negative (-) black cable from each of the loads to the negative DC bus. 4. Connect the incoming positive (+) red cable from each of the loads to the positive DC bus. 5. Install fuses for the DC loads and the DC battery. The bottom four DC fuses are for the battery. Fuses for DC loads should be Littelfuse Type 257 or equivalent and the maximum allowed fuse for the DC loads is 20 A. Important: You may remove the PCB with the positive DC bus an

Summary of the content on the page No. 20

Xantrex AC to DC Converter Connecting the Panel to the XADC DC Side When following the procedure, see Table 2 on page 24 for wire lengths and Table 1 on page 24 for torque values. To connect the panel to the XADC DC side: 1. Remove the DC wiring compartment panel on the XADC (see Figure 8). 2. Loosen the positive and negative screws on the DC connection lugs (see Figure 15). 3. Route the large positive (+) red cable and negative (-) black cable from the panel through the DC wiring compartment


Alternative user manuals
# User manual Category Download
1 Sony User manual TV Converter Box 2
2 Sony 409 User manual TV Converter Box 0
3 Sony DSBK-1504 User manual TV Converter Box 3
4 Sony BKPF-L752 User manual TV Converter Box 17
5 Sony DSBK-1504P User manual TV Converter Box 2
6 Sony Walkman WM-FX488 User manual TV Converter Box 7
7 Sony PCWA-DE80 User manual TV Converter Box 1
8 Accton Technology Media Converter EC3802-WDM User manual TV Converter Box 3
9 Agilent Technologies E4400-90246 User manual TV Converter Box 0
10 Agilent Technologies E7402A User manual TV Converter Box 5
11 Agilent Technologies 1660AS User manual TV Converter Box 0
12 Agilent Technologies 8590 User manual TV Converter Box 0
13 Addlogix HD-SD Down Converter Board HKDW-702 User manual TV Converter Box 1
14 Airlink101 ATVC101 User manual TV Converter Box 1
15 Airlink101 ATVC102 User manual TV Converter Box 3