Haier AD42NAMBEA user manual

User manual for the device Haier AD42NAMBEA

Device: Haier AD42NAMBEA
Category: Air Conditioner
Manufacturer: Haier
Size: 0.36 MB
Added : 7/19/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Haier AD42NAMBEA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Haier AD42NAMBEA.

For your convenience

If looking through the Haier AD42NAMBEA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Haier AD42NAMBEA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Haier AD42NAMBEA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Haier AD42NAMBEA User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Haier AD42NAMBEA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Haier AD42NAMBEA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DUCT TYPE AIR CONDITIONER
Operation & Instruction
Manual
AD182AMBEA
AD242AMBEA
AD242AMERA
AD28NAMBEA
AD36NAMBEA
AD42NAMBEA
No. 0010572489
G
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.

Summary of the content on the page No. 2

Table of Contents Cautions 2 3-5 Safety Precautions Parts and Functions 6 Malfunction 7-8 Care and Maintenance 9 For Preparation of Heating("Hot Keep") 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12-18 1

Summary of the content on the page No. 3

Cautions Disposal of the old air conditioner important observations relating to the assembly, operation and maintenance of the Before disposing an old air conditioner that air conditioner. goes out of use, please make sure it's inoperative and safe. Unplug the air The manufacturer does not accept conditioner in order to avoid the risk of responsibility for any damages that may arise child entrapment. due to non-observation of the following instruction. It must be noticed that air conditioner sys

Summary of the content on the page No. 4

Safety Precautions Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on

Summary of the content on the page No. 5

Safety Precautions CAUTION Do not wash the air conditioner with water. Make sure to use a fuse of proper electric Do not install the system where the air outlet reaches directly the flora and fauna. rating. It could cause electric shocks. Use of steel or copper wire in place of a fuse is strictly It will not be good for their health. prohibited because it could result in a trouble or fire accident. It is strictly prohibited to place a container of Neither stand on the air conditioner nor Do not

Summary of the content on the page No. 6

Safety Precautions The machine is adaptive in following situation 1. Applicable ambient temperature range: Rated Maximum Minimum DB C 27 32 18 Indoor WB C 19 23 14 Cooling DB C 35 43 10 outdoor WB C 24 26 6 20 27 15 DB C Indoor Heating 15 -- -- WB C 7 24 -7 DB C outdoor 6

Summary of the content on the page No. 7

Parts and Functions Duct Air outlet Air inlet AD182AMBEA AD242AMBEA AD242AMERA AD28NAMBEA Duct Air outlet Air inlet AD36NAMBEA AD42NAMBEA 6

Summary of the content on the page No. 8

Malfunction please check the following things about your air conditioner before making a servie call. Unit fails to start Is the power source Is city supply power in Isn't the signal receiving Isn't the earth leakage switch adjust cut in? normal? section exposed to the breaker in action? direct sunlight or strong ON illumination? It is dangerous. Turn off OFF Power the power supply switch stoppage? immediately and contact Power supply switch is the sales dealer. not ON. Cooling or heating is not

Summary of the content on the page No. 9

Shuru Shuru Malfunction The followings are not malfunction When the air conditioner is started, when the compressor starts or Water flowing stops during operation or when the air conditioner is stopped, it sound is heard. sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. Cracking sound is heard. This is caused by heat expansion or contraction of plastics. It smells. Air which blows out from the indoor unit sometimes smells. The s

Summary of the content on the page No. 10

Care and Maintenance Points to observe Turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. Do not ON use! Thinner Benzine OFF Tooth powder CAUTION Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped. Cleaning CAUTION Do not dry the air filter with fire. Do not run the air conditioner without the air filter. Care and Cleaning of the unit Clean w

Summary of the content on the page No. 11

For Preparation of Heating("Hot Keep") "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode. Defrosting operation (in the heating mode): When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minut

Summary of the content on the page No. 12

Is The Unit Installed Correctly Confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself. Installation place Avoid installing the air conditioner Install the unit at well ventilated Install the air conditioner firmly on near the place where possibility of place. the foundation that can fully support inflammable gas leakage exists. the weight of the unit. Explosion (Ignition) may occur

Summary of the content on the page No. 13

Installation Manual For Indoor Unit 1. Safety precautions Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, WARNING and , those points which are related to the strong possibility of an installation done in error CAUTION resulting in death or serious injury are listed in the W section. However ARNING , there is also a

Summary of the content on the page No. 14

Installation Manual For Indoor Unit NOTICE All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor. WARNING BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAI- LURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS IN

Summary of the content on the page No. 15

Installation Manual For Indoor Unit (4) Preparation for suspending the unit (a) Size of hole at ceiling and position of hanging bolts 57 A 137 (Hanging bolt position) 30 B (Ceiling hole size) C (Ceiling ~ panel (Panel dimensions) wrap dimensions) Unit: mm Dimensions A B C Model AD36NAMBEA 1406 1600 1660 AD42NAMBEA AD182AMBEA AD242AMBEA 1000 1180 1240 AD242AMERA AD28NAMBEA (b) Hanger bolts installation Use care of the piping direction when the unit is installed. I

Summary of the content on the page No. 16

Installation Manual For Indoor Unit Hanging bolt (5) Installation of indoor unit M10 nut M10 washer Fix the indoor unit to the hanger bolts. If required, it is possible to suspend the unit to the beam, etc. Directly by use of the bolts without using the hanger bolts. M10 spring washer Main unit Note When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot holes of hanging bracket. Piping side Adjusting to the levelness Supply water (a) Adjust the out-

Summary of the content on the page No. 17

Installation Manual For Indoor Unit Secure the elevation as high as possible (d) When constructing drain piping for several units, position the (approx. 100 mm) common pipe about 100 mm below the drain outlet of each unit as shown in the sketch. Use VP-30(11/4") or thicker pipe A downhill grade of VP 30 for this purpose. 1/100 or more (e) Be sure to provide heat insulation to hard PVC pipes of indoor placement. 290~325mm (f) Do not ever provide an air vent. Right overhead (g) The height of the d

Summary of the content on the page No. 18

Installation Manual For Indoor Unit (7) Installation work for air outlet ducts Air conditioner main unit Heat inlet duct insulation (optional or Suction panel Ceiling surface marketat item) (Silent panel) B Special blowout A Blowout duct C special inlet (option) (Optional or marketed item) (Option) (with air filter) Hole for check Calculate the draft and external static pressure and select the length, shape and blowout. A Blowout duct 2-spot, 3-spot and 4-spot with 200 type

Summary of the content on the page No. 19

Installation Manual For Indoor Unit 5. Electric wiring WARNING DANGER OF BODILY INJURY OR DEATH TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS. (1) Selection of size of power supply and interconnecting wires. Precautions for Electric wiring Electric wiring work should be conducted only by authorized personnel. Do not connect more than three wires to the terminal block.

Summary of the content on the page No. 20

HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P.R.China Web Site: http://www.haier.com


Alternative user manuals
# User manual Category Download
1 Haier 0010515194 User manual Air Conditioner 1069
2 Haier 0010506358 User manual Air Conditioner 90
3 Haier 0010515690 User manual Air Conditioner 40
4 Haier 0010518181 User manual Air Conditioner 28
5 Haier 0010518358 User manual Air Conditioner 42
6 Haier 0010516146 User manual Air Conditioner 29
7 Haier 0010518526 User manual Air Conditioner 20
8 Haier 001051 User manual Air Conditioner 25
9 Haier 0010530627 User manual Air Conditioner 38
10 Haier 0010515222 User manual Air Conditioner 16
11 Haier 0010552537 User manual Air Conditioner 18
12 Haier 0010554405B User manual Air Conditioner 5
13 Haier 0010557172 User manual Air Conditioner 12
14 Haier 0010571223 User manual Air Conditioner 12
15 Haier 0010571570 User manual Air Conditioner 11
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21