Best IP29M Series user manual

User manual for the device Best IP29M Series

Device: Best IP29M Series
Category: Ventilation Hood
Manufacturer: Best
Size: 2.31 MB
Added : 2/4/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Best IP29M Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Best IP29M Series.

For your convenience

If looking through the Best IP29M Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Best IP29M Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Best IP29M Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Best IP29M Series User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Best IP29M Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Best IP29M Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
HB0063
IP29M SERIES
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION ON
PAGES 12 TO 14.
®
In USA - BEST P.O. Box 140, Hartford, WI 53027
®
In Canada - BEST 550 Lemire Blvd., Drummondville, QC, J2C 7W9
REGISTER YOUR PRODUCT ON LINE AT: www.bestrangehoods.com/register
For additional information — visit www.bestrangehoods.com
V08072 rev. A

Summary of the content on the page No. 2

! ! WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO PERSONS SHOCK OR INJURY TO PERSONS, OBSERVE IN THE EVENT OF A RANGE TOP GREASE THE FOLLOWING: FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the 1. SMOTHER FLAMES with a close-fitting lid, cookie manufacturer. If you have questions, contact the sheet or metal tray, then turn off the burner. manufacturer at the address or telephone number BE CAREFUL TO PREVENT BURNS. IF THE l

Summary of the content on the page No. 3

- IP29M SERIES RANGE HOOD SYSTEM - INTERIOR BLOWERS Model 647 Model 634 or 644 Model 437 Model 441 (High capacity roof cap) (10’’ Round wall cap) (7” Round wall cap) (roof cap) Model 418 Model 415 (10” round adjustable elbow) (7” round adjustable elbow) Model 410 Model 407 (10” round duct—2 ft. sections) (7” round duct—2 ft. sections) Model 427 Model 423 Model 424 Model 454 Model 453 1 1 1 1 1 1 1 1 1 1 (4 /2” x 18 /2” (4 /2” x 18 /2” to (4 /2” x 18 /2” to (4 /2” x 18 /2” (4 /2” x 18 /2” to 1

Summary of the content on the page No. 4

- IP29M SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERS Model 441 Model 437 Model ILB9 (800 cfm) (10” Round wall cap) (High capacity roof cap) Model EB12 (1200 cfm) or ILB11 (1100 cfm) or EB15 (1500 cfm) in-line blower exterior blower Model EB6 (600 cfm) (includes two 8” x 12” to or EB9(900 cfm) 10’’ round transitions) exterior blower Model 441 Model 643 (10” Round (8” Round wall cap) wall cap) Model ILB6 (600 cfm) in-line blower (includes two 4½” x 18½” to 10’’ round transitions) Mode

Summary of the content on the page No. 5

1. SELECT BLOWER OPTION AND INSTALLATION TYPE Either an interior or an exterior blower or in-line blower may be used with this hood. The Best by Broan IP29M Series must be installed with blower models P6, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately.) Plan where and how the ductwork will be installed. If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 9, 11 to 15, 17

Summary of the content on the page No. 6

2. MEASURE INSTALLATION Dimensions for the most common installation are shown beside. Framework The minimum hood distance above cooktop must not be less than 30’’. A maximum of flush to ceiling 36” above cooktop is highly recommended for best capture of cooking impurities. Decorative flue Distances over 36” are at the installer and users discretion. A cover or drywall Since framework must be flush to ceiling, 4 decorative flue covers have been created to fit both with trim hood widths and diff

Summary of the content on the page No. 7

4. PREPARE THE BLOWER HOUSING A B B Detach the blower housing from the hood by removing its both retaining screws (A). Keep the screws for further use. Fold up its both flanges (B). The flanges must be perpendicular to the top of the blower housing. HD0229 5. REMOVE THE FILTERS AND THE GREASE DRIP RAIL 1 A. Remove tape on filters. Remove filters from hood and set aside. NOTE: It is recommended to start with the central one. B. Remove tape on grease drip rail (1). Lift out grease drip rail and

Summary of the content on the page No. 8

7. BUILD THE FRAMEWORK ! WARNING When building framework, always follow all applicable construction codes and standards. The framework must be sized to support the total weight of the hood. Refer to the table below for total weight of the hood, according to the type of blower chosen. HOOD WIDTH WITH P6 INTERIOR BLOWER WITH P12 INTERIOR BLOWER WITH IN-LINE OR EXT. BLOWERS (ROUGH-IN PLATE ONLY) 42” 71 LB 84 LB 52 LB 54” 86 LB 99 LB 67 LB 7.1 SUGGESTED FRAMEWORK FOR INSTALLATION WITH DECORATIVE FLU

Summary of the content on the page No. 9

8. INSTALL BLOWER HOUSING Use both screws (A) previously removed in step 4 to assemble the blower housing to the mounting brackets. For installation with decorative flue cover AEIWP Series only, place 4 nuts (B) (from flue cover parts bag) on the pem studs, leaving 1/4” for the hood installation. The blower housing must be installed in such a way that its label (C) will be on the same side as the hood control side. See illustrations below. INSTALLATION WITH INSTALLATION WITH DECORATIVE FLUE COVE

Summary of the content on the page No. 10

12.CONNECT THE WIRING WARNING ! Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally. Remove wiring cover from rough-in plate and set aside. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw. Reinstall wiring cover. 13.FINISH THE DRYWALL

Summary of the content on the page No. 11

16.INSTALL THE BLOWER (INTERIOR OR EXTERIOR BLOWER) Refer to instructions included with blower. Once the blower is installed, plug the blower cord (A) into the female receptacle and the power supply cord (B) onto the male connector inside the hood. AB ! WARNING Do not plug the two cords into each other. HE0078 17.REINSTALL THE PAN CAUTION Remove protective plastic film covering pan sides and tape over halogen lamps. Using a Phillips no. 2 or Robertson no. 2 screwdriver and the retaining screws,

Summary of the content on the page No. 12

19.LIGHT BULBS REPLACEMENT WARNING ! In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures. This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included). ! WARNING In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing them. 12 3 1. To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.

Summary of the content on the page No. 13

R O S 21.OPERATION Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter. 1 2 5 6 7 8 9 10 11 3 4 AIR max REFRESH HC0032 1.Halogen light push-button 6. Maximum blower speed icon INSTEON™ Master Link Mode push-button 7. Particulates sensor icon 2. Blower push-button 8. Blower speed level/ 3. Enable/Disable func

Summary of the content on the page No. 14

21.OPERATION (CONT’D) Grease filter reset  Once the grease filter cleaning is done, press on the grease filter reset push-button (item 4 on control illustration) to reset the filter maintenance timer. This will also shut off the grease filter maintenance icon (item 5 on control illustration). Grease filter maintenance indicator  After 30 hours of operation, the grease filter maintenance icon (item 5 on control illustration) appears. This means filters need to be cleaned.  Once the grease fi

Summary of the content on the page No. 15

SERVICE PARTS IP29M SERIES 1 5 2 3 4 6 7 8 9 10 11 12 HL0094 KEY PART QTY (HOOD WIDTH) NO. NUMBER DESCRIPTION 42’’ 54’’ 1 V08069 CONTROL PROCESSOR UNIT 11 2 V08073 PARTICULATES SENSOR 11 3 V13924 MALE CONNECTOR 11 4 V13923 FEMALE CONNECTOR 11 5 V08074 CONTROL INTERFACE 11 6 V16569 LAMP SHELL, SOCKET AND TRIM ASS’Y 46 7 V05921 HALOGEN BULBS (50 W, 120 V, PAR16, GU-10) 4 6 V16967 EVOLUTIONARY™ HYBRID BAFFLE FILTER 8.95” X 8.61” X 1” (INCL. ITEM 10) 2 - 8 V16968 EVOLUTIONARY™ HYBRID BAFFLE FILTER 1

Summary of the content on the page No. 16

WARRANTY WARRANTY ONE-YEAR LIMITED WARRANTY Broan-NuTone LLC (“Broan-NuTone”) warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair


Alternative user manuals
# User manual Category Download
1 Best IS241 User manual Ventilation Hood 17
2 Best IS102 User manual Ventilation Hood 1
3 Best CP37 User manual Ventilation Hood 4
4 Best IEX170 User manual Ventilation Hood 1
5 Best CP35 Series User manual Ventilation Hood 2
6 Best ISER222 User manual Ventilation Hood 0
7 Best IS23 SERIES User manual Ventilation Hood 1
8 Best EB9 User manual Ventilation Hood 1
9 Best K210A User manual Ventilation Hood 0
10 Best K3139 Series User manual Ventilation Hood 4
11 Best K29 User manual Ventilation Hood 0
12 Best K42 User manual Ventilation Hood 1
13 Best K273 User manual Ventilation Hood 3
14 Best K15 User manual Ventilation Hood 0
15 Best K41 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0