BEST Range Hoods PIK33 user manual

User manual for the device BEST Range Hoods PIK33

Device: BEST Range Hoods PIK33
Category: Ventilation Hood
Manufacturer: BEST Range Hoods
Size: 3.71 MB
Added : 2/4/2014
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for BEST Range Hoods PIK33. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with BEST Range Hoods PIK33.

For your convenience

If looking through the BEST Range Hoods PIK33 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual BEST Range Hoods PIK33 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual BEST Range Hoods PIK33 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
BEST Range Hoods PIK33 User manual - Online PDF

Explore the detailed user manual for BEST Range Hoods remarkable creation, Model PIK33. Gain valuable insights and instructions to maximize your device's capabilities and optimize your user experience. Uncover the full potential of your BEST Range Hoods PIK33 device through this comprehensive user manual, offering step-by-step guidance and expert tips for effortless operation and enjoyment.

Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual BEST Range Hoods PIK33 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to BEST Range Hoods PIK33. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
HB0030
MODELS PIK33 AND PIK45
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNE: USE AND CARE INFORMATION ON PAGES 12 and 13.
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
REGISTER YOUR PRODUCT ON LINE AT: www.BestRangeHoods.com/register
For additional information - visit www.BestRangeHoods.com
V05862 rev.

Summary of the content on the page No. 2

! ! WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO PERSONS IN SHOCK OR INJURY TO PERSONS, OBSERVE THE THE EVENT OF A RANGE TOP GREASE FIRE, FOLLOWING: OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the 1. SMOTHER FLAMES with a close-fitting lid, manufacturer. If you have questions, contact the cookie sheet or metal tray, then turn off the manufacturer at the address or telephone number burner. BE CAREFUL TO PREVENT BURNS. listed in

Summary of the content on the page No. 3

- PIK33 AND PIK45 INSERT SYSTEM - INTERIOR BLOWERS Model 647 Model 643 (7” Round (8” Round wall cap) wall cap) Model 634 or 644 8” Round (roof cap) Model 415 adjustable elbow 7” Round (optional) adjustable elbow (optional) 8” Round Model 407 standard (7” Round x 24” duct section) 8” Round 7” Round metal flexible duct metal flexible (optional) duct (optional) Model 412 Model 413 Model 459 Transition Transition Transition (3¼” x 10” to 7”) (3¼” x 10” to 8”) (3¼” x 14” to 8”) Adapter and dampe

Summary of the content on the page No. 4

- PIK33 AND PIK45 INSERT SYSTEM - IN-LINE AND EXTERIOR BLOWERS Model 441 Model 437 (10” Round wall cap) (High capacity roof cap) Model ILB9 (800 cfm) Model EB12 (1200 cfm) or ILB11 (1100 cfm) or EB15 (1500 cfm) In-line blower Exterior blower Model EB6 (600 cfm) (includes two 8” x 12” to or EB9 (900 cfm) 10” round transitions) Exterior blower Model 441 (10” Round Model 643 wall cap) (8” Round wall cap) Model ILB6 (600 cfm) In-line blower (includes two 4½” x 18½” to 10” round transitions) Model

Summary of the content on the page No. 5

1. SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in-line blower may be used with this insert. The insert model PIK33 or PIK45 must be installed with blower models P5, P8, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately). Plan where and how the ductwork will be installed. Access to the top of the hood is preferred for connection of ductwork. As an alternative, flexible metal ductwork may be us

Summary of the content on the page No. 6

3. INSTALL BACKSPLASH (OPTIONAL) It is recommended to install the backsplash before the custom hood insert. The custom hood will cover the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18” clearance between bottom of custom hood and range control panel or cooktop. (See instructions packed with backsplash.) 4. CUSTOM HOOD PREPARATION ! WARNING When building a custom hood, always follow all applicable construction codes and standards. Th

Summary of the content on the page No. 7

6. INSTALL CUSTOM HOOD LINER (OPTIONAL) The liners are specially designed to protect the exterior base of the custom hood. To order, refer to the table below to find the right liner model number for your insert and width of custom hood. To view specific model information, including depths for each liner models, visit www.BestRangeHoods.com or contact Technical support (phone number listed on page 14, in warranty text). To install, see instruction packed with custom hood liner. The liner must be

Summary of the content on the page No. 8

10. REMOVE THE KNOCK-OUT OPENING (INTERIOR BLOWER) Remove the knockout on rough-in plate. See picture below. CAUTION When using P5 blower, remove the 10” wide knockout (smaller part). If using P8 blower, remove the knock- out corresponding to the ducting installed (10” or 14” adapter/damper). HD0077 Removing vertical knockout opening on rough-in plate 11. INSTALL THE DEVIATOR (INTERIOR BLOWER) Install the deviator as shown. NOTE: To prevent the deviator from sliding out of the rough-in plate, p

Summary of the content on the page No. 9

13. CONNECT WIRING (ALL BLOWERS) ! WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Position insert below the installed custom hood. Pull cable through hole in top of insert. INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Re

Summary of the content on the page No. 10

16. DUCTING CONNECTION (ALL BLOWERS) A. When there is access to the top of the hood, connect ductwork and seal connections with duct tape after Step 17 Install the insert. B. When there is no access to the top of the hood, carefully pull down the metal duct through the custom hood base hole. Slide this duct over the transition (interior blower) or over the flange of the rough-in plate (in-line or exterior blower). Make sure the adapter/damper assembly enters the ducting. Seal the connection w

Summary of the content on the page No. 11

18. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D) Install (4) no. 8 x 3/8” screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the (4) screws. HD0044 HD0045 Single blower (P5) Dual blower (P8) Secure the blower by installing 2 more no. 8 x 3/8”

Summary of the content on the page No. 12

19. LIGHT BULBS This insert must use shielded halogen lamps (120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base), included. ! WARNING 12 In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures. 1. Install the lamps by placing the bulb leads into their grooves in the socket. 2. Gently push upwards and turn clockwise until secure. ! WARNING In order to prevent the risk of personal injury, the halogen lamps must HO0090 be cooled down

Summary of the content on the page No. 13

21. USE AND CARE (CONT’D) Avoid: when choosing a detergent - Any cleaners that contain bleach will attack stainless steel. - Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly. -Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range. 22. OPERATION Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Let the blower

Summary of the content on the page No. 14

WARRANTY BROAN ONE-YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any produc

Summary of the content on the page No. 15

SERVICE PARTS SINGLE BLOWER/ROUGH-IN (Model P5) 1 20 21 2 22 23 19 3 4 18 17 5 7 16 15 6 14 8 13 6 12 9 11 10 HL0021 KEY NO. PART NUMBER DESCRIPTION QTY. 1 1 V13296 ADAPTER AND DAMPER 3¼” x 10” 1 2 V03500 AIR DEFLECTOR 1 3 V12997 SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY 1 4 V03577 FOAM 1/2” x 1/2” x 12” 1 5 V02160 CAPACITOR 15MFD 4 6 V01869 MACHINE SCREW NO. 6-32 x 1/4” 1 7 V01857 WIRE COVER 1 8 V01582 LOCK NUT NO. 6-32 1 9 V14973 SINGLE BLOWER ASSEMBLY 1 10 V01810 IMPELLER RING 1 11 V03400 BLOWE

Summary of the content on the page No. 16

SERVICE PARTS DUAL BLOWER/ROUGH-IN 2 (Model P8) 22 24 1 23 25 3 4 21 5 20 19 18 6 17 16 7 15 14 8 9 11 13 10 12 HL0022 KEY PART NUMBER DESCRIPTION QTY. 1 1 V14971 ADAPTER AND DAMPER 3¼” x 14” 1 2 V13296 ADAPTER AND DAMPER 3¼”x 10” 1 3 V03500 AIR DEFLECTOR 1 4 V14975 DUAL BLOWER ROUGH-IN PLATE ASSEMBLY 1 5 V03577 FOAM 1/2” x1/2” x 12” 1 6 V01582 LOCK NUT NO. 6-32 2 7 V02160 CAPACITOR 15MFD 2 8 V01857 WIRE COVER 1 9 V01766 MOTOR 165 W CW 1 10 V03400 BLOWER IMPELLER, HOOD 7.094” x 3.375” CW 1 11 V1

Summary of the content on the page No. 17

GUIDE D’INSTALLATION HB0030 MODÈLES PIK33 ET PIK45 ! ! CONÇUS POUR USAGE DOMESTIQUE SEULEMENT LIRE ET CONSERVER CES INSTRUCTIONS INSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE. PROPRIÉTAIRE : DIRECTIVES D’UTILISATION ET D’ENTRETIEN EN PAGES 28 ET 29. BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711 BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866 737-7770 ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.BestRangeHoods.com/register Pour obtenir plus d’information, consulte

Summary of the content on the page No. 18

! ! AVERTISSEMENT AVERTISSEMENT AFIN DE RÉDUIRE LES RISQUES D’INCENDIE, AFIN D’ÉVITER TOUT RISQUE DE BLESSURES LORS D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES, D’UN FEU DE CUISINIÈRE, SUIVEZ CES INSTRUCTIONS* : SUIVEZ LES INSTRUCTIONS SUIVANTES : 1. Étouffez les flammes avec un couvercle hermétique, une tôle à biscuits ou un plateau métallique et 1. N’utilisez cet appareil que de la façon prévue par le ensuite, éteindre le brûleur. PRENEZ SOIN manufacturier. Si vous avez des questions, cont

Summary of the content on the page No. 19

MODÈLES PIK33 ET PIK45 - SYSTÈME DE MODULE DE HOTTE ENCASTRABLE - VENTILATEURS INTÉRIEURS Modèle 647 Modèle 643 (Capuchon de mur (Capuchon de de 7 po rond) mur de 8 po rond) Modèle 634 ou 644 (Capuchon de toit) Coude ajustable Modèle 415 de 8 po (optionnel) Coude ajustable de 7 po (optionnel) Conduit Modèle 407 standard de (Conduit de 7 po rond 8 po rond section de 2 pi) Conduit de métal flexible Conduit de métal de 8 po rond flexible de 7 po (optionnel) rond (optionnel) Modèle 412 Modèle 413

Summary of the content on the page No. 20

MODÈLES PIK33 ET PIK45 - SYSTÈME DE MODULE DE HOTTE ENCASTRABLE - VENTILATEURS EN LIGNE ET EXTÉRIEURS Modèle 437 Modèle 441 Ventilateur en ligne Ventilateur extérieur (Capuchon de toit à haut rendement) (Capuchon de mur Modèle ILB9 (800 pcm) Modèle EB12 de 10 po rond) (1200 pcm) ou ILB11 (1100 pcm) ou EB15 Ventilateur extérieur (incluant deux transitions (1500 pcm) Modèle EB6 (600 pcm) rondes de 8 po x 12 po ou EB9 (900 pcm) à 10 po) Modèle 441 (Capuchon de Modèle 643 mur de 10 po (Capuchon r


Alternative user manuals
# User manual Category Download
1 BEST Range Hoods PIK45 User manual Ventilation Hood 4
2 Sony SH-L35W User manual Ventilation Hood 0
3 Air King AIF8X User manual Ventilation Hood 3
4 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
5 Air King AIF10X User manual Ventilation Hood 0
6 Agilent Technologies 31A User manual Ventilation Hood 0
7 Air King 500CFM User manual Ventilation Hood 0
8 Agilent Technologies 6610XA User manual Ventilation Hood 1
9 Air King AIK14X User manual Ventilation Hood 0
10 Agilent Technologies HP 83621A User manual Ventilation Hood 0
11 Air King 380 CFM User manual Ventilation Hood 38
12 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2
13 Air King AD series User manual Ventilation Hood 1
14 AEG DD 8665 User manual Ventilation Hood 4
15 AEG 230 D User manual Ventilation Hood 1